Product Overview
Wilcox Associates, Inc. is proud to bring you version 3.5
of PC-DMIS. Version 3.5 provides you with one of three variations
of PC-DMIS that can be customized to fit your exact needs:
PC-DMIS Pro - A simplified user interface designed
for basic inspection but with many available options for somewhat
complex measuring needs.
PC-DMIS CAD - Designed for working with imported CAD
models to increase the ease of creating inspection programs
as well as analyzing complex geometries.
PC-DMIS CAD++ - The complete version of PC-DMIS with
Gear and Blade meausuring package options.
For more information on these variations, see these Software
Demonstrations.
|
|
![[Dividing Line Image]](../images/div.gif)
System Requirements
To Install and use PC-DMIS you will need:
- Windows Operating System (Windows NT 4.0, Windows 2000
or Windows XP). Note that Windows
95, Windows 98, and Windows ME are no longer supported
and PC-DMIS 3.5 will NOT function on computers using
these operating systems.
- Graphics card that supports OpenGL shading. We cannot
specify an exact graphics card since every user has varying
needs.
- Pentium-III or higher processor.
- 128MB of RAM is recommended but significantly more may
be required if working with large CAD models.
- 250MB of free hard drive space minimum for the application.
- SVGA capable monitor.
- CD-ROM drive.
|
Depending on your specific
needs, the recommended system specifications
for this version of PC-DMIS may be much higher. Be sure
to consult with your PC-DMIS distributor to find out
the type of computer system you will need in order to
run this software at its optimum capability.
|
|
|
Back to Top
New Features & Enhancements
Version 3.5's major features and enhancements
include the following:
Other enhancements are described in these categories
|
NEW USER INTERFACE
A New user interface layout was created that made it possible to include
the following features:
- User specific layout profiles that are accessed and saved based
on the Windows OS User Name.
- Layouts that are user customizable for every different operator.
- Support for adding/removing menus via a new interface Customize
dialog.
- Support for adding/removing buttons to toolbars via the Customize
dialog.
- A dockable Edit Window.
32 BIT LANGUAGE SUPPORT
Support was added for 32 bit character set languages including
translations of Chinese, Japanese, and Korean. This now makes it
possible to translate PC-DMIS into any language commonly in use
in the world based on customer demand and local support.
MOVE TO REGISTRY SETTINGS
All of the PC-DMIS saved settings contained in the formerly used
PCDLRN.INI file were transferred to the Windows Registry for better
protection, usability, and performance. Along with this:
- A Settings Editor was created that provides access to the PC-DMIS
specific items in the Windows Registry for ease of changing, saving,
exporting, importing and deleting while not in the PC-DMIS environment.
- Auto Feature parameters were added into the Windows Registry
saved settings. - Registry settings for automation were also added.
- A ClearWAIKeys.exe utility was also created to facilitate complete
removal of PC-DMIS settings from the Windows Registry.
- New installations of version 3.5 will automatically search
for the PCDLRN.INI file and copy the settings into the Windows
Registry if the file exists.
NEW 'QUICK START'
TOOLBAR
A new Quick Start toolbar was created to assist operators by creating
a more simplified user interface. Easy graphical access is now provided
to feature measurement routines, Auto Features, Dimensions, and
Constructions as well as having many predefined measurement routines
useful in creating relationships and alignments. It is also inclusive
of easy access to probe utilities.
DIRECT CAD INTERFACE
TRANSLATORS
Direct CAD Interface (DCI) translators are now available for Unigraphics,
CATIA, and Pro-Engineer. This is an ability to provide one-pass
CAD file translation when the Direct CAD Interface (zero-pass, zero
translation) is not available and two-pass file translation (IGES,
STEP, VDA, etc.) is undesirable.
Back
to Enhancements
PROBE UTILITIES ENHANCEMENTS
- Automated probe calibration of all tools in a probe changer
or stylus changer rack.
- Identifiable parameter sets are now used in probe calibration
that allow the user to save calibration specific information such
as prehit, move speed, hit points and associate them with a specific
probe file.
- The full path name of the currently used probe file is shown
in the Probe Utilities dialog and can also be seen in the Edit
Window.
- Access to the Search Path from the Probe Utilities dialog is
now available.
SCANNING ENHANCEMENTS
- Rotary Scan capability which allows scan at a fixed distance
about an axis and parallel to that axis and with freedom of movement
in that axis.
- UV patch scans can now be easily defined and created though
the scan dialogs.
- Scanning with FINDNOMS, RELEARN and no CAD will construct a
curve from the new data and compares the closest points of the
curve to the original scan points. This allows analog scanning
with a comparison to a previous data set.
- Added option to maintain current hit increment at the end of
a patch scan line to the next line segment. This is to produce
smoother data for surfacing and reverse engineering applications.
This is for TTP only.
- An Auto Move capability similar to that used in Auto Features
was added to all scan types.
- An ability in Scanning to reset boundary points back to zeroes.
This is particularly useful when creating consecutive patch scans
with a lot of boundary points.
- A NULLFILTER method was added for taking points in Direction
1 with analog probes to maintain a regular hit interval based
on the Point Density and not filter these points based on the
hit increment.
CONSTRUCTIONS ENHANCEMENTS
- The construction of arcs and lines from scans is now possible.
- Ellipses can now be constructed from points.
- Added support to create an intersection point between an ellipse
and a line.
DIMENSIONS / STATISTICS
ENHANCEMENTS
- Added the symmetry dimension.
- Added the ability to save the state of datum conditions for
true position dimensioning for repetitive dimensioning for similar
features.
- Added the ability to put a limit on the number of characters
that can be entered into a trace field value. The default is 15
but this can now be set to a smaller number.
- Added the ability to dump/delete the XSTATS11.TMP file from
inside the PC-DMIS environment.
- Added the ability to display dimensions and constructed features
from an attached part program in feature list boxes.
- Limited the feature list for dimensions to appropriate feature
types for the Dimension dialog that has been opened.
- Added the ability to only show dimensions in the report that
falls within a specific percentage of the defined tolerance.
- Forced Point Info and Dimension Info dialogs to redraw when
the underlying dimensions are updated in learn mode.
- True Position deviations can now be displayed as radial deviations
in addition to diametrical.
- Automotive industry standard abbreviations can now be displayed
in conjunction with True Position dimensions to illustrate the
direction of deviation.
- Added the ability for profile dimensions to display the contour
plot or the color interpolation regardless of the types of scans
or features used.
- The nominal dimension for Angularity can now be automatically
filled when selecting (2) features.
- A Delete Dimensions dialog is now available and can be activated
from the Graphics Window as well as the menu item.
- A Database Wizard was created to facilitate easy creation or
registration of ODBC compliant statistical databases.
FEATURES ENHANCEMENTS
- Edge Point Only Mode for learning new edge points.
- Added the ability to edit feature hits for some Measured and
Auto Features in the graphics window.
- Added the capability to control the amount of each radius measured
on Round Slots in Auto Features.
- Find Vector (Vector Point) now works for a group of box-selected
points rather than just one.
- Modified some complex dialogs to include "Advanced" and "Basic"
buttons for better viewing.
- Added a browse button on the External Command dialog.
CAD ENHANCEMENTS
- Improved Best fit and re-pierce CAD to find better nominal
information.
- Added support for the STL file format.
- Added the ability to associate one CAD file with multiple part
programs.
- Added the ability to mirror and keep the old CAD data so that
is possible to get both halves of a symmetrical part.
- Added support for selecting from all available coordinate systems
within a given DCI.
GRAPHICS ENHANCEMENTS
- Added the ability to place the color contour mapping of scan
profiles directly on the CAD image.
- Added the ability to display the tessellated image of a DCI
part even if the CAD license is not currently available.
- Added a dialog to access the Display Points as Spheres option.
- Added support for continuous scanning simulation. The probe
will flow along the part when using an SP600 probe.
MASTER / SLAVE ENHANCEMENTS
- Extended the use of the Execute From Cursor mode to include
master and slave modes.
- Added the ability to show both probes, machines and readout
windows for master/slave setup.
OPERATIONS / EXECUTION
ENHANCEMENTS
- Hot keys to switch between round and flat guess modes for manual
machines. These combinations are CTRL + SHIFT + R and CTRL + SHIFT
+ F.
- Added the ability to move all axes [5] simultaneously (DCC
machine and PH9 type wrist). Note: Not all brands of machine controllers
support this option.
- Added an option to not display the dialog box or warning during
execution for External Commands to aid with automation.
MAJOR ENHANCEMENTS
FROM PREVIOUS VERSIONS
- All menu items now are associated with icons to assist in the
internationalization of PC-DMIS.
- The appearance of PC-DMIS was modernized with new icons to
assist in differentiating version 3.5 from previous versions.
- A new Windows Layout toolbar allows users to customize and
save several layouts of the PC-DMIS operator environment.
- Automated to the fullest extent possible most standard probe
changers. Particularly the Renishaw ACR1 (Autochange).
- A progressive software upgrade structure for PC-DMIS was created
that includes three different levels of PC-DMIS. These levels
are referred to as PC-DMIS Pro, PC-DMIS CAD, and PC-DMIS CAD++.
These 3 levels provide an optimum of selectionability at the time
of purchase and are customizable to each individual user requirement.
- A new variable type called "Structures" was implemented. A Structure
is a type of variable that can contain sub-elements,
OTHER ENHANCEMENTS
- A warning was adding to the Opt. Probe dialog when changing
any settings since changing these parameters can significantly
affect analog scanning performance and accuracy.
- The CTRL + SHIFT + END key combination will now place the cursor
at the end of the Edit Window while in Summary Mode.
- Message boxes now appear to alert users that their software
contract is about to expire.
- PC-DMIS now shows arrow heads on lines in the graphics window
to show direction.
- The ability to find nominals on a specific surface for any
given point was added.
- A special sheetmetal toolbar was added for PC-DMIS Pro.
- A combination selection box was added for selecting probe files.
- Base components of probe file descriptions are retained when
creating new probe files.
- A new File Options toolbar for the common File menu options
was added.
- A Browse button was added to help in creating customized toolbar
buttons.
- Vertical mounting of some probe changers is now allowed (MCR20,
SCR200, SCR600, ACR1).
- Pop-up text boxes now reflect learn-time array values.
- A new menu item was added for Edit Command. This was previously
only available with the F9 key.
- Warning messages concerning probe head rotation now include
information about the angles.
- The Insert Tip Calibration command now has a dialog.
- During simultaneous on-line/off-line program execution, only
the active part program execute dialogs will be shown.
- More user selectable control is available for probe calibration.
- An Edit Tool button was added to the Master/Slave Calibrate
dialog.
- Automatic feature recognition was added for Auto Cone.
- Scroll bar positions with feature select list boxes now commence
from the end of the list.
- High points can now be found from groups of points rather than
just scans or feature sets.
- The Edit Window will now open automatically when importing
programs from previous versions.
- The full file name of DCI files can now be illustrated.
- Group selecting in the Point Info dialog list boxes is now
possible.
- Master/Slave setup can now be entered without opening a part
program.
- New True Positions dimensions can reference previously defined
datums thereby reducing the amount of selecting required.
- The accuracy of showing path lines has been improved.
- UV scan direction can now be reversed by reversing the start
and end points in the UV Scan dialog.
Back
to Enhancements
|
Back to Top
Back to Top
PTB Certified
PC-DMIS for Windows version 3.5 has been PTB certified. This
certification ensures that the math algorithms used in this
version of PC-DMIS adhere to known standards.
See these scanned images for more information:
For more information on PTB certification, visit this site:
http://www.ptb.de/index_en.html
|
|
Back to Top
![[Dividing Line Image]](../images/div.gif)
Updates and Fixes for MR1
To download v3.5 MR1 please visit the Version
3.5 Software Download Page
Download the fixes listed below in .doc format:
Version 3.5's Maintenance Release 1 contains these fixes
and updates:
Enahancements:
No major enhancements since the initial release.
Fixes:
- The CART/POLAR toggle in the Auto Features dialog didn't
correspond to the parameter in the edit window.
- Reset Global Variables When Branching Flag was mistakenly
being set for DMIS programs.
- Basicscans from imported v3.2 programs could not be deleted
in the Edit Window Summary Mode.
- The Settings Editor Cancel button was not working.
- Hyper-report page orientation affected printing of other
print orientations.
- Default page orientation is now saved with each hyper-report.
- Leader lines were not being constructed in the graphics
window for filter set features.
- Asian Fonts did not display in Summary Reporting Window.
- Auto Points could not be created from a DES set.
- Dimension columns were occasionally not printing out correctly.
- F9 on BasicScan (after F9 on UV, F9 on patch) made PC-DMIS
go to a confused condition.
- Perimeter scans around features were not always generating
correctly.
- The Probe Calibration Utilities Location values were always
in Metric.
- The Error zone value did not update based on program units.
- Init hits of other than 0 with Perm hits of 0 for Edge
type Linear Open Scans was not working.
- The Polar / Cartesian toggle for generic features was
operating in reverse in the German language.
- The Polar interface actual probe diameter was not being
transferred to the PC-DMIS Probe Info Dialog.
- Programs with dimensions inside of loops were not reporting
the dimensions to the inspection report.
- Problems were encountered with intermediate moves between
sample hits and the user-defined hits from DMIS imported
sheetmetal features.
- Guess Mode toolbar reverted to Round Guess Mode after
measuring a feature.
- Learning iterative alignments which utilized the Error
label would execute infinitely if the learned alignment
didn't solve.
- Some extended sheetmetal commands were not being exported
to DMIS.
- Undoing deleted alignments didn't update Dimension values.
- When taking auto feature sample hits, PC-DMIS wasn't displaying
the feature name.
- Constructed perpendicular and parallel planes were not
calculating correctly.
- The Add-Ins toolbar was not listed in the toolbars listing.
- Metal thickness could not be calculated correctly when
using the Unigraphics DCI.
- Re-selecting Normal for scan execution mode and then the
OK button caused the hits to go to 0.
- Some machine settings were being altered in the Settings
Editors for non-Administrator user accounts.
- The XYZ position readouts occasionally paused with the
Polar interface.
- The actual probe position was not correctly displaying
for the Polar interface in the Graphics Window.
- The Polar interface was added.
- Cutting the CAD for section scans after the first section
was not always trying to insert the scan segment in the
correct location of the Edit Window.
- When using ReLearn, the scans remembered the start points
but not the end points for each segment of the scan.
- CAD Info time stamps were not updating with tessellated
data changes.
- PC-DMIS was crashing on the reload of any DCI model.
- Some LK interface machines were not properly homing.
- When executing a manual scan with a fixed probe, the probe
readout window reverted back to machine coordinates.
- Equate alignment was not updating MIN/MAX dimensions.
- Reloading a program that accessed the SolidWorks DCI was
excessively slow.
- A very slow response to Exit command occurred when using
SolidWorks DCI.
- Attempting to move hit points after displaying hits for
an Auto Feature caused application errors.
- Pressing 'ESC' closed the Settings Editor without any
warnings.
- All of the hits of section scans were displayed in Summary
Mode.
- Switching between two open programs caused the graphics
window to be un-maximized.
- PC-DMIS could not be installed with Domain Administrator
account.
- Auto check box was not checked automatically in the Dim
Info dialog.
- While using an empty TutorElement to assign fields to
a generic element, PC-DMIS terminated without notification.
- The Flat/Round Guess buttons defaulted to Round Guess
after each feature measurement.
- Auto-trigger beeping was not functioning with the GOM
interface.
- Subroutines were not always returning the correct updated
values.
- Tracefields were being made available for editing during
execution.
- Measuring Auto Circle Studs with Read Position was causing
probe crashes.
- Constructed features that reference non-existing features
caused the drawing of these features.
- After doing Ctrl+D to delete a feature, clicking and dragging
and then deleting caused application errors.
- Importing IGES shell entity type 514 was causing memory
problems.
- The Feature Buttons toolbar was removed.
- Import of IGES files with some shell type entities was
not supported.
- Patch scan with using the NULLFILTER only scanned the
1st row.
- Rotary scans were not properly following a fixed radius.
- An unnecessary warning was generated when constructing
a BF Recomp Cylinder.
- The Option Tab in the Fixture Design dialog did not have
properly aligned text in the German resources.
- No protection was provided if an operator loaded a wrong
size column during a recovery process.
- The Fixture Recovery dialog was not properly displaying
in the German language.
- Fixture Verify when OFFLINE did not work properly.
- The Settings Editor was incorrectly requiring Administrator
privileges for some interface options.
- Trying to import Catia DCI files without Read/Write permissions
produced erroneous error messages.
- Dimension display results were not well aligned.
- The CAD didn't resize dynamically when selecting on the
Custom Layout buttons.
- Priority of commands was not being properly established
in dual-arm part programs.
- Un-Install was leaving the custom_menus folder and the
install_errors.log file.
- The correct number of dimension tolerance zones was not
showing in graphical reporting mode.
- Inserting moves after taking a hit caused the move to
go to the top of the edit window.
- The Guess Mode button was removed from the Measured Features
toolbar.
- Closing a Quick Start Measure dialog after taking a hit
gave an application error.
- Could not enter 'assign' in the Edit Window in PC-DMIS
PRO.
- Variables with extensions inside features weren't being
updated if the main variable name was changed.
- EDIT WINDOW PRINT SETUP didn't work in non-English resources.
- Tip compensation was being incorrectly applied to circles
constructed from Gaussian filters constructed from scans.
- Guess mode was functioning improperly when specific features
were selected to be measured.
- Hyper-report objects couldn't be moved while holding the
<CTRL> Key.
- Catia DCT hung during the import process with some MODEL
files.
- DMIS imported Edge Points were not executing correctly.
- IF/ENT_IF, ELSE/END_ELSE statements were not translating
to
- The System-5 gripper was gripping the columns twice on
slave arm machines.
- The default button in the Settings Editor was changed
to Save Settings.
- Application errors were generated after the slave arm
finished placing System-5 columns.
- System-5 was requiring administrator privileges in order
to be able to use it.
- Auto Cones were not always calculating along the correct
vector.
- Auto Features were being created with 0 for measured values
if FindNoms was enabled in Offline.
- Override FindNoms window error display did not reference
the thickness value.
- Using only priority surfaces was not working correctly.
- Choosing BF Recomp in the scan segment dialog caused application
errors
- Symmetry Dimension Graphic Display was drawn in space
away from the features
- Changing the nominal in a dimension prompted excessively
to update a feature's nominals.
- The restore button on the PC-DMIS mainframe window was
not working properly.
- If the dialog for the scan segment circle was opened and
closed without changing anything, and then it was opened
again, then the second time opening the input scan was not
selected.
- Canceling out of scan segment arc construction
- Font problems caused menu items to appear in English when
using Japanese resources.
- The Help description of the Auto Circle stud was incorrect.
- It was not possible to deselect Tip Angles in the Probe
Utilities dialog.
- Scan segment arcs were sometimes drawn as full circles.
- The order of the combo boxes in the settings toolbar was
change to place Probes next to Probe Tips.
- Application errors occurred when executing programs with
cast points that did not have a feature specified.
- Spaces could not be used in the construction dialog feature
ID.
- Programs would not save if analysis windows of single
points used color interpolation.
- The SP600MSTAR probe model was not utilizing all 9 connection
points.
- The Save As dialog Version edit box was not correctly
sized.
- The Axila machine interface was added and installation
problems resolved for this interface.
- System5GripperOffset registry setting existed only on
the Slave Arm.
- Find Vector didn't work with the 5-Unique Create Fixture
Window.
- System-5 column recovery was not working for Arm2 machines.
- Module orientation information was missing from System-5
setup.
- Reloading the active part program was causing application
errors on exit.
- The printed probe list had an extra backslash \ character
in the pathname.
- Programs with scan segment arc and line commands were
incorrectly being allowed to be saved in v3.25 format.
- System-5 positioning label formats were incorrect.
- System-5 setup for Volume information was simplified.
- The delete button was not working to delete a System-5
fixture in F9 edit mode.
- System-5 columns were not being shown as being loaded
in the correct positions.
- System-5 column verification was selecting incorrect columns.
- Circles could not be constructed from a scan segments.
- A message box was added to warn of Find Nominals errors
with measured features.
- Message boxes weren't displaying System-5 setup information.
- Opening a new line and then attempting to view pop-up
window information produced application errors.
- Spaces at the end of System-5 fixture filenames caused
errors during program execution.
- Pressing the ESC key was causing the Fixture Setup dialog
to close without warning.
- The tempdata.dat file now generates warnings when the
file size is more than 250K.
- Incorrect probe offsets were being used at the start of
System-5 gripper calibration.
- Move point coordinate were not correcting with alignments
inside of loops.
- The rotary table axis was not being locked for manual
jog box moves.
- Some SolidWorks DCI files could not be imported.
- Incorrect messages were being displayed during System-5
Arm 2 column recovery.
- System-5 status bits only synchronized during recover
columns.
- Hyper-report leaderlines were not connecting correctly.
- Toggling the units of the dimension location was causing
the graphical image to draw incorrectly.
- Dimensioning runout without a second input feature was
not dimensioning about the origin.
- Measured points were not snapping to an alignment axis
when using fixed probes.
- Deleting two constructed midpoints together was causing
application errors.
- Hyper-reports created in previous versions were not importing
correctly.
- Blanked features were being mistakenly displayed when
importing Unigraphics files.
- Spacing in the Probe Readout Window was not well organized.
- The Find coordinate function was not work in with Auto
Point type features.
- Offset value signs were being inverted when constructing
offset lines in loops.
- The text for some menu items was not properly aligned.
- Some translation problems with Italian text were corrected
or improved.
- Perpendicularity with MMC in Chorus DMIS programs was
not importing correctly.
- Column Transfer Location frame was being shown in Fixture
Setup dialog when doing manual fixturing.
- The Column Transfer Location was not context-sensitive
with respect to Manual/DCC mode.
- Edit Window generated RTF files were not correctly showing
multi-byte characters.
- Comment dialogs were not waiting for operator inputs during
execution in PC-DMIS Pro.
- Material condition modifiers were not being created for
Visual Basic script exports.
- Curve construction was being limited to 530 points.
- Not all features learned from cad were obtaining the CAD
ID.
- A new AlternateTessellation tessellation algorithm improves
shading of surfaced STEP models.
- The title bar in opened part programs was displaying old
version information.
- Temperature compensation was not always updating to current
temperatures.
- Deleting extremely large groups of features from a program
took excessive amounts of time.
- No tab text was in the property sheets of hyper-report
objects for foreign resources.
- Lines constructed from some sheetmetal features could
have the wrong vector.
- The ACR1 toolchanger was not working with MM4 Execute.
- Hyper-report object property sheets did not have text
in the tabs of non-English resources.
- Communication were not being properly established with
a Mora ANC39 controller.
- Automation was not allowing the creation of circle math
types other than best fit.
- Piercing a B spline curve with a ray does not always work. If
this fails, the operator will need to set the Registry option
AlternateCadMath=1.
- A High Point tutorial was added.
- Edit window visibility was not correctly restoring after
hiding and closing a part program.
- Filenames could not be discerned if a pathname was created
in an assignment statement.
- Enhancements to the Common Firmware were preventing constant
update of Leitz interface information.
- Feature ID's were not being exported into basic scripts.
- Report RTF file output could not be controlled when using
marked sets.
- The measured hit points were not being calculated correctly
for Auto Cones.
- The Probe Utilities graphics window was not always updating
properly when deleting components.
- The name property of Automation part object was only returning
".PRG".
- The Sharpe interface was not allowing manual override
during DCC execution.
- If AutoReset was set to zero for the Tech80, the scales
were not always being reset on start of PC-DMIS.
- Lines could not always be used for rotation in alignments.
- The CAD Info dialog was not showing the correct import
path for Pro-E files.
- Generic constructions were not serializing correctly on
saving which prevented opening in versions.
- It wasn't possible to select more than 119 features in
a Construction dialog.
- The best fit math was not solving for Auto Cones.
- Auto Create Edge Point Mode was creating points with incorrect
vectors.
- Box selecting of Auto Circles was not working.
- Comment variables were not always updating.
- Axis scans were not always working with laser probes.
- Loading part programs created in v3.25 was operating too
slowly.
- Some scan dialogs were not showing the complete text for
some entry descriptions.
- The GETCOMMAND and GETTEXT functions were failing.
- The Catia DCI Modules Directory edit box was not accepting
enough characters.
- Imported DMIS constructed lines did not always have the
correct vector.
- The negative sign was not being included in variables
for tolerances.
- Faro interface communications problems were resolved.
- Autocalibration did not support wrist mapping on a dual-arm
machine with infinite wrists.
- Help for CMM Options was not correctly linked.
- Could not install PC-DMIS from a Domain Administrator
account.
- Clicking on the Active Tip List followed by a Ctrl+Home
keystroke produced application errors.
- Automatically created dimensions were not being saved
in the Edit Window.
- Dimension Info boxes in Hyper-reports were not always
printing in the same location.
- Circular Move was disabled for all circles imported from
an MM4 program.
- Solid Works version compatibility was not being correctly
checked.
- Rotary scan was not working properly.
- Cast cylinders were not being created with the correct
IN/OUT type.
- The ProE DCI was not allowing import of *.asm file types.
- F9 edit mode was not available for Hyper-Reports from
Summary Mode.
- Breakpoints didn't function correctly after running a
BASIC script
- Profile dimensions did not automatically update their
values if an alignment was changed.
- Best Fit alignment weights were utilizing only default
tolerances.
- Spaces after the $ in DMIS programs were causing translation
errors on import.
- DMIS dimension commands were always being imported in
inch units.
- Auto Circles created from AVAIL imports had Auto Move
set to YES with Distance equal to 0.
- Files necessary for Catia DCI were being installed in
the wrong directory.
- Manually edited tip IJK vectors were not being saved.
- The FLEXTOOL.dat file did not contain the CN200 or CN500
columns.
- Find Nominals was not working for all sections of a multi-section
scan.
- PC-DMIS Pro was missing the ability to do screen captures.
- PC-DMIS Pro was missing the ability to insert an alignment.
- The DMIS FEAT/OBJECT was not correctly supported for DMIS
import.
- The Chorus DMIS FC(label) was not supported.
- Executing scans that were converted to points was causing
application errors.
- The ProE DCI settings for the Settings Editor were not
well documented.
- "Show Dialog" menu item on "Auto" toolbar's shortcut menu
didn't deselect
- Switching to DMIS mode in programs with unreferenced profile
dimensions produced application errors.
- Qualifying via Automation was not saving the probe results
file in the correct location.
- Automation pathnames were returning names containing the
tilde ~ if more than 8 characters.
- Programs containing external subroutines took excessive
time to start execution.
- Error messages referencing external objects were expanded
to include path names.
- The External Command window browser changed the current
PC-DMIS folder.
- Find and replace did not work well for strings containing
a backslash / character.
- Renishaw probe heads had to be manually reset if a seating
error occurred during execution.
- Default values for error messages were not being loaded
for the Unigraphics DCI.
- Additional options were added for saving PC-DMIS attributes
to Solid Works DCI files.
- Changes in probe orientation were not always updating
graphically for the Faro interface.
- The Guess Mode toolbar was re-appearing after closing
a program using a hard probe and then opening a part program
that did not contain a hard probe.
- Default button on Toolbar tab of Customize dialog wasn't
working.
- The Numerex interface stretch values could not be properly
entered in the registry.
- Using alignments inside loops could cause extra movement
of the CMM.
- Internal errors were causing some outside Auto Circles
to be measured twice.
- Temperature Compensation Setup dialog was not correctly
importing the Serv1.stp values.
- Creating a new marked set icon after deleting on inserted
the new icon in the wrong order.
- The PH1 rotation increments we incorrectly defined.
- True Position dimensions were not being correctly exported
to Visual Basic scripts.
- Solid Works DCI cached data files contained the wrong
date after creation.
- CAD files generated from the Pro-E DCI were attempting
to connect to the Pro-E workstation.
- The Marked Sets window was showing when opening part programs.
- Rotary tables were not correctly communicating with the
DEA interface.
- 2D bestfit rotate only was not working.
- Only the first page of multi-page hyper-reports could
be edited.
- If and Autofit Best Fit alignment failed, the operator
was not warned of the error.
- Initialization of the Tech80 interface was not completing
correctly.
- Exporting some programs in IGES format produce application
errors.
- Setting Show Inputs for Best Fit alignments to OFF was
having no effect during execution.
- The SP600 5 point qualification routine was improve to
minimize the possibility of the probe crashing into the
shank of the qualification tool.
- A probe change on the Romer arm was causing a loss in
accuracy.
- Point selection on curves was not properly working.
- Romer arms were not correctly compensating for diameter.
- The NC-100 sensor was not capable of being used on the
slave arm of a dual-arm machine.
- File Output not working in Operator Mode online.
- Variables that used extensions could not be directly used
in expression fields.
- An inch part program was maintaining the tolerance values
of metric dimensions in inches.
- Using the Tolerances button in the Probe Utilities dialog
was causing an application error.
- The TutoRun instruction Reset (F0,STATUS) could return
the wrong value.
- The Sheffield controller Error 50 was not being properly
processed by PC-DMIS.
- Translating the CAD origin via Make CAD 3D was destroying
the CAD graphics.
- Round Guess Mode was not working correctly with the Faro
machine.
- Switching between multiple programs kept minimizing the
graphics window.
- The Calculations function of DPUPDATE was working correctly.
- The ACR3 8 port configuration was not calibrating correctly.
- Wizard icons were not being properly depicted.
- A Re-Pierce CAD option was being incorrectly shown in
the Iterative Alignment Wizard.
- Number of points was shown as % in German for all QuickStart
dialogs.
- After starting a new part program, clicking the Print
button in the Results window of Probe Utilities was causing
various problems.
- It was difficult to scroll the edit window while trying
to highlight commands.
- Axis reassignment was not allowing the Leitz interface
to correctly calculate the SP600 matrix.
- Keystrokes were not being allowed to change values in
the basic scan dialog edit fields.
- Pierce point construction was generating errors even though
the point was being created.
- Undoing a scan that was converted to points was losing
the basic hit data.
- AnswerWorks Runtime was not always installing correctly.
- Inserting an Autocalibrate Tip command was not correctly
adjusting for tip diameter when using the Leitz protocol
Trax calibration on common firmware controllers.
- The Alignment option was not present in the Spanish menu
resources.
- With auto hyper-report turned on and auto print on load
set, the report printed without dimensions.
- The dimension Search ID list boxes were returning the
cursor to the end of the list after deselection.
- Calculation of the increments used for wrist calibration
was improved.
- Some complex structured variables were not reporting correctly.
- Multiple hyper-reports were being allowed to be opened
for editing. Now only one is allowed.
- IGES files could not be imported when using the French
version.
- Continuously holding the Enable button with Leitz firmware
was only collecting the first probing point.
- Opening a Hyper-report while it was already open was causing
application errors.
- Slave Arm Autocalibrate Probe commands were not executing
the correct positioning moves.
- Feature sequence numbers for Auto Cones were not updating.9
- Construction of some surfaces was producing application
errors due to memory problems.
- Creating a BF constructed cone in the Edit Window and
then changing the feature type was producing application
errors.
- Collision detection was not working correctly.
- Probe compensation wasn't working correctly with the Johansson
interface.
- Re-opening a program created with the Solid Works DCI
was causing various errors.
- The DMIS output file name was changed to be the same as
FILNAM/ statement.
- Some windows belonging to one program were not being hidden
when switching between programs.
- PDF output had extra blank lines in some features.
- Auto Cylinders were not being included in standard or
Pro versions of PC-DMIS.
- SPC Database Dialog Box wasn't linked to the Help file.
- The LK interface was responding slowly to manual hits
during execution.
- Opening the SMX Tracker Pad 2 times was causing run-time
errors.
- Icons for custom menu items were not implemented.
- Application errors were generated if a CAD file needed
to change Windows TMP variables.
- RMEAS functionality was causing probe crashes for imported
DMIS programs.
- Unigraphics fixed a problem where UG was not releasing
applications utilizing a UG file.
- The Unigraphics DCI was updating too frequently.
- The Save As dialog Version selection field was too small.
- Support was added for USB portlocks.
- Creating a UV scan without using the generate button was
creating scans without points.
- Opening the feature edit dialog with F9 on the same feature
twice was causing the edit dialog open for the following
feature.
- The RAMOPTIC probe was incorrectly defined as a trigger
device.
- The Analysis nominal line color was changed to black to
improve visibility.
- Saying No to take manual points after a scan interruption
following an emergency was generating an application error.
- An AlternateTesselation algorithm improves shading of
Catia DCI files.
- The LK v5.3 interface was not correctly processing movespeed
commands.
- Find Nominals ability was improved by limiting the number
of surfaces that could be used.
- The Automation PutText command was not supporting all
possible values for PC-DMIS.
- Construction dialogs no longer open an extra window when
changing the Feature ID.
- Improvements were made to the graphical display of shaded
surfaces.
- The Probe Wizard was crashing when the Add button was
pressed if invalid probe angles were entered.
- Some VDA files were causing application errors on import.
- Some VDA-FS files would cause application errors on import.
- Check distance was implemented for the Mitutoyo interface.
- Not all of the correct features were appearing in Auto-Zoom
Hyper-Reports.
- An AlternateTessellation registry option was added to
improve tessellation of some IGES files.
- Breaking the SMX tracker beam was causing problems with
the ADM function.
- The Finish button was being made available in the Iterative
Alignment dialog even if the feature selection was not finished.
- The iterative alignment wizard was not allowing correct
"drag and drop" or Next functionality.
|
|
Back to Top
![[Dividing Line Image]](../images/div.gif)
Updates and Fixes for MR2
To download v3.5 MR2, please visit the Version
3.5 Software Download Page
Download the fixes / improvements listed below in .doc format:
Version 3.5's Maintenance Release 2 contains these fixes
and improvements:
- The auto feature THEO values were changing when actual
metal thickness was changed in the Edit window.
- Temperature sensor reading are now exposed as variables.
- Temperature compensation was not correctly applied for
Arm2 while in dual-arm control.
- The probe type would remain NULL if an error occurred
during a CW43L probe change.
- Using the surface point find option could have produced
application errors.
- Deletions of more then 50 program lines are no longer
tracked for the Undo function.
- A Mitutoyo machine was stopping after executing a program
external command.
- Prehit and retract for slots was not being calculated
correctly.
- Some DMIS alingments would not execute.
- It was not possible to construct an intersection point
by selecting 2 graphicals lines.
- The Mitutoyo GPIB interface was not communicating with
the Renishaw PH10.
- Windows listed in the Window Menu were incorrect when
the basic script editor was open.
- A carriage return after a SNSLCT command would prevent
execution of an import DMIS program.
- Learning a round slot from surface data was not always
calculating the correct dimensions.
- Communication problems with the Reflex interface were
resolved.
- PC-DMIS could not find subroutines when using the "Search
Specified Directory" setting from the set search path dialog.
- Positive reporting dimensions weren't showing correct
if the positive tolerance was negative.
- Nested subroutines were not executing.
- Restarting statistics after cancelling execution was
not prompting the user correctly.
- Graphical analysis views were too big in the report when
in solid mode.
- After a Save, Close and Open operation the feature nominal
were sometimes being corrupted.
- Alignments were being created with blank recall statements.
- Some tool tips were updated to display the proper text.
- Rotary scans in a non-Z axis were not displaying correctly
graphically.
- The diameter not showing up in command mode for some
auto features.
- If a True Position dimension was fully constrained, the
datum bonus was not properly initialized.
- When creating a UV scan with clearance planes active,
the ClearPlane checkbox was not marked.
- Graphical true position tolerance lines could not be
turned off.
- It was not possible to display auto feature hits unless
show hits was checked.
- UV scans were generating incorrect hit vectors.
- The check box functions for "Show Out of Tolerance Only"
and "Show Dimensions Within Limits" did not work correctly.
- Not all toolchangers were prompting before probe head
rotation during calibration.
- Activating leader lines in hyper-reports was causing
dimension boxes to reposition.
- Probe heads weren't rotating as commanded on Mora machines.
- Statistics ouput to a file was not working.
- Concentricity dimensions were not calculating correctly
if the reference feature was the origin.
- Application errors happend when constructing a BFRE MIN-SEP
ID circle from a BasicScan circle.
- The Auto Move associated with a basicscan circle could
not be edited.
- Constructions for spheres and cylinders were being allowed
with only 3 inputs.
- Measured features were moving off of the CAD image after
an iterative alignment.
- Basic scan theoreticals were being retained from the
previous execution.
- Label colors did not change after changing the feature
appearnce until the label was moved.
- Views resized to defaults every time you clicked OK in
the View Setup dialog.
- Using F1 to open the help file was sometimes causing
runtime errors in the help file.
- Status bar prompting was not being cleared when associated
dialogs were closed.
- Some dialogs could have positioned off the screen on
opening with customized toolbars.
- The Windows Add/Remove programs function was not being
properly updated with PC-DMIS installation information.
- DMIS variables used in alignments weren't working properly
after import.
- Screen capture was not clipping views if they were of
solid images.
- The new module fixture dialog was not working correctly.
- PC-DMIS equal signs (=) used in comments were being converted
to the abbreviation "EQ." in the DMIS window.
- The start point for showing path lines was not drawing
correctly.
- Application errors happened in PC-DMIS by clicking undo
after cancelling a scan.
- Probe rotations weren't happening correctly following
a jump in a program with Leitz firmware.
- PC-DMIS had applicatioin errors if the Catia DCI was
not available during execution.
- The auto cone angle was not accurate when learning from
CAD.
- The auto cone hole/stud type was switching after some
mouse clicks.
- Changing the nominal data for a dimension in command
mode was not updating the feature nominals as desired.
- The Avail auto cone was translating in as a measured
cone.
- Measured cylinders weren't updating the measured length
value after execution.
- The STATS/TRANSFER command was linking to the wrong file
for transfer.
- F1 on any statistics command always returned help for
the STATS/ON command.
- Avail cylinders were importing with the incorrect diameter
and no height.
- Importing DMIS cylinders could have incorrect results
if the first 3 points were not in a row.
- Profile dimensions now default to Form and Location on
creation.
- Find nominals on auto spheres was not working during
learning.
- Commands located after subroutine calls were not having
their tool tipvalues updated based on the subroutine.
- Seperators in the Window menu were misplaced.
- The automation function for App.UserExit was not working
correctly.
- Application errors could happen when editing a variable
in a commont to point to a different object.
- The Edit Window has now been made available while the
hyper-view editor is open.
- The translators were updated to support UnigraphicsNX.
- Passing parameters to a hyper-report via automation was
not working.
- Giving a variable value to a hyper-report property caused
exiting of PC-DMIS.
- Status bar prompting was not always correct during learning
of auto features with find nominals.
- Constructing circles from cones or cylinders always resulted
in an outside circe.
- Spheres constructed from points in the same plane were
erroneously added to the part program.
- Editing hyper-reports was causing PC-DMIS toolbars to
be re-arranged.
- Checking tooltips on assignment commands could have caused
application errors.
- Auto cone measured IJK values were not being updated
after execution.
- Profile of feature set deviation arrows were drawing
incorrectly after cancelling execution during an iterative
alignment sequence.
- Opening and closing a program containing labels produced
an application error.
- The GEOMETRIC/CONE and CYLINDER commands were not translating
the IS/IC/OC for inside/outside feature types correctly
when importing MM4 programs.
- Geometric circles and slots had the rmeas feature set
to the reference plane in imported MM4 programs.
- Imported MM4 programs with counter-clockwise measured
circles were not executing correclty.
- Arrows depicting graphical deviation inside the part
weren't visible.
- Catia DCI surfaces were being imported as surfaces and
also as skins.
- Movement patterns around the ACR1 calibration sphere
were improved.
- Marked sets were not being saved.
- Roundness of Cylinders was not updating the graphical
diameter based on scale correctly.
- The analysis window "Show Best Fit, Max Inscribed, and
Min Circumscribed Diameters" option was on by default.
- The CAD window was not capable of hiding via automation
commands.
- Tip changes were sometimes being ignored when the followed
a LOADPROBE command.
- Arm2 toolchanger positions were not saving correctly
when calibration in multi-arm mode.
- Some IGES files had edges that could not be trimmed correctly.
- Loops containing angle offsets were not executing correctly.
- Extra spaces at the end of variable names will now be
trimmed from subroutine calls.
- The has ContinuousCJoint flag was causing operational
problems for non-administrator users of some Leitz firmware
systems.
- The toolcs.dat file was not transmitting correctly to
the toolc.dat file on the Arm2 computer.
- Hyper-reports that couldn't be found during execution
were causing blank report windows to open.
- Multiple screen captures at the end of a program were
not being printed in the report.
- The graphics were doing a scale to fit after each click
to find a hit on the CAD
- Application errors occurred when creating a location
dimension with form of a basic circle scan.
- Measured spheres were not having hits regenerated when
selected after an F9 edit.
- Surfaces were not indicating as being selected when generating
a perimeter scan.
- Summary mode fonts were changing after execution.
- The common Leitz firmware machine jogbox was not changing
properly between coordinate systems.
- After unmarking a warning, closing and then reopening
PC-DMIS showed the warning below the previously unmarked
warning was unchecked and the warning that was unmarked
was remarked.
- Graphical deviation arrows were not visible when images
were printed on a high resolution printer. The registry
entry for DrawColorInterpLineWidth now controls the arrow
width.
- With an ACR1 mounted vertically, the probe moved too
deep into each slot during calibration.
- Post out to basic contained to many "DmisCommand.Marked
= True" lines.
- TEXT/QUERY had L as the comment string instead of the
actual comment string after a DMIS import.
- PC-DMIS will now automatically add a hit to imported
DMIS files if the points in the files do not include a hit
command.
- The F9 edit dialog did not reflect the correct number
of hits for all auto features.
- Z-Origins were not always the same place as it is within
CATIA files after import.
- The print button did not work when quick start toolbar
was open.
- The dialog for inserting external commands is now available
in PC-DMIS Pro.
- Status bar prompts were incorrect after clicking on CAD
with the auto features dialog open.
- Find nominal mode was not working correctly for edge
points.
- Circle end angles were not being executed correctly in
imported AVAIL programs.
- AVAIL reference planes were being remeasured as sample
planes after import.
- Slots from AVAIL programs had the wrong orientation after
import.
- Doing Save As in a program with a referenced CAD file
was creating a copy of the file.
- Advanced sheetmetal dimensions were being allowed to
be created without proper permissions.
- Status bar prompts were not correct when learning auto
features in nominals mode.
- Auto features that required sheet metal options were
incorrectly visible in command mode.
- Adding a READPOINT then deleting it and then adding another
READPOINT caused an application error.
- When memory errors are encountered during import of Catia
files, PC-DMIS will automatically try a different tessellation
value.
- Importing some Catia files with arcs resulted in extra
circles being drawn.
- The ProEngineer translator caused application errors
when importing extremely large files.
- In the Ctrl-Enter insert mode of the edit window, up/down
arrows moved two lines at a time.
- Concatenation of a string with an array component displayed
strange result in the pop-up window.
- Incorrect status bar prompts happened with auto features
open in nominals mode.
- Small arcs in Unigraphics files were importing as complete
circles.
- Basic scan theoreticals were being retained from the
previous execution.
- A print command used after a subroutine call caused application
errors.
- Generic feature construction was missing from PC-DMIS
Pro.
- Graphical deviation arrows were not being drawn perpendicular
to centerline when using that option in true position dimensions.
- Screen captures were using excessively large bitmaps
and not scaling them properly.
- Some programs using Catia files created with a DCI could
not be opened without the DCI.
- ST2 probe release and attach commands were not working
correctly with a Zeiss-GPIB interface.
- Zeiss-GPIB machines were stopping at the end of each
feature measured during execution.
- Metrolog interface horizontal machines did not move correctly
based on probe head orientation.
- "Draw lines above surfaces" did not always draw correctly
with profile deviations.
- Scroll bars were missing from the hyper-report window.
- Some DWG file curve entities were not importing correctly
in PC-DMIS.
- Doing an Alt - on high point was causing an application
error.
- Improvements were made to the handling of clearance plane
commands.
- Analysis view objects sometimes exceeded the printable
view area.
- Execute from cursor was not working properly with constructions
inside of loops.
- STL files that started with whitespace characters were
not importing properly.
- The Automation "Print" command was changed to be "PrintEditWindow".
- Some programs using Catia files created with a DCI could
not be opened without the DCI.
- The analysis window was not showing correctly when captured
to the report.
- Auto cones were changing their locations if the alignment
changed.
- Landscape mode was not being made available for hyper-reports.
- Extremely large Unigraphics files caused application
errors on import.
- The IN/OUT toggle was sometimes switching on very small
arcs.
- Improvements were made to the functioning of slider bars
on the Quick Start tool bar.
- Offset lines used in alignments were not being mirrored
properly.
- The probe image sometimes didn't display with the auto
features dialog open.
- Get Math errors were generated when constructing a pierce
point using a perfect CAD radius and a line.
- Japanese characters didn't fit in all dialogs shown during
installation.
- Application errors could occur on closing a part program
that employed automation search IDs.
- Resources weren't being installed properly on WindowsXP
for the languages of Chinese, Japanese Portuguese, Spanish,
and French.
- Installation problems in the Japanese language were corrected.
- The automation function SetActivePartProgram caused application
errors when passed a NULL input.
- The DefaultFilePath automation helpstring showed read-only
instead of read-write.
- Large red arrows were displaying after construction of
lines and points.
- Defined path scanning ability was improved with Sharpe-32z
controllers.
- IgnoreMotionErrors was not always available in all modes
in PC-DMIS Pro.
- Generic features were enabled for PC-DMIS Pro.
- Hyper-reports without dimensions were being generated
as blank reports.
- Johansson machines did not retract from the final probing
point in a part program.
- The Guess button was missing from the measured features
toolbar.
- DWG export was not properly formatting 3D elements.
- Nested subroutines would try to execute even if they
were not called.
- Vector errors weren't being scaled properly during learning
with Autmatic Scale to Fit enabled.
- Creating 2 scans consecutively could have caused an application
error.
- On F9 of a constructed feature in the edit window PC-DMIS
showed an extra input highlighted.
- It wasn't possible to turn off dimension options for
angle between dimensions.
- AVAIL features were being imported with relative measure
active.
- Flat features were being guessed while in Round Guess
mode after a leapfrog was executed.
- Faro calibration results are now available in the probe
utilities results data file.
- Thickness was not being applied properly to some surface
points.
- Application errors happened when undoing a scan deletion.
- The edge point surface vector was not mirroring correctly.
- Customized toolbars now save on exit of the customize
dialog.
- PC-DMIS could have crashed after clicking on Level within
the Iterative Alignment dialog.
- Multiple ENDSUB commands in subroutines were causing
application errors.
- Iterative alignments created in v3.25 were failing when
executed in v3.5.
- Variables in Chorus DMIS programs were not improting
correctly.
- Iterative alignment did not check for sufficient level
and rotate feature prior to creation.
- Graphical arrows did not always show the correct dimensional
color related to decimal precision.
- Planes constructed from scans could have had the plane
vector reversed.
- Some spurious exiting of PC-DMIS happened when writing
programs online with an LK interface.
- Changing auto feature nominal values was automatically
changing target values.
- Equate alignment was not working properly in all situations.
- Popups with lengthy variable statements would go off
the right side of the screen if the edit window was docked
on the right.
- Values larger than 9999.999mm could not be displayed
in the Probe Readout Window.
- The Global Used function in Probe Utilities caused application
errors if probe files existed that were from newer part
programs.
- TutoRun was not launching from the PC-DMIS File menu.
- The CMMI.DLL was not being installed with the Geodetic
V-STARS interface.
- The System-5 DeltaGrapColZ value was always being reset
to 0.
- Some typographical errors were corrected in the Expression
Builder dialog.
- Measured features created offline were not having labels
added to the Edit Window.
- Marked sets are now created with the current marking
at the time of creation.
- Changing the workplane in a part program will now update
dimensions that follow it.
- The axis for the current workplane is now non-selectable
when creating 2D distance dimensions.
- Manually entering a generic feature in the Edit Window
was not drawing it in the Graphics Window.
- With Text Analysis on, hit data was not showing up.
- English strings are now used in reporting true position
dimensions in Chinese.
- The first point in textual analysis was pushed to the
right if the feature name was long.
- Dimension blocks were going off the right edge of the
printed inspection report.
- Hyper-reports created in v3.25 and saved to PDF were
not saving properly in v3.5.
- Multi-select in hyper-reports to edit the property pages
only worked for the first item selected.
- Dimension histograms didn't use properties to draw histograms.
- Constructed features were not asking if the default naming
convention should be changed if a constructed feature name
was changed.
- Italian language resources were improved.
- Messages were added to warn the operator at the start
of partial execution operations.
- Parameter sets were not correctly maintaining all tip
orientations of star tips.
- Using Full Report Mode in Korean created application
errors if location dimensions existed.
- Screen Capture to Report was not properly scaling the
CAD graphics.
- Application errors happened on a second attempt to create
a linear open scan using SinglePoint and Generate.
- The DMIS import progress bar was not refreshing when
switching between applications.
- Deleting multiple items in summary mode was not deleting
all of the correct items.
- There was no way to change the output labels for DMO
files.
- The SP600Q now supports the SCR600.
- The warnings dialog options were out of synchronization
with the check boxes in the dialog.
- DMIS Mode of the Edit Window did not support entering
negative dimension tolerances.
- F9 edit of a hyper-report could cause an application
error.
- Some DMIS programs could not be imported if extra DATASET
commands existed.
- Fixtures could not be placed if the 5-Unique assembly
axes were not aligned to the machine axes.
- Feature numbering was not sequential for looped features
in the graphics window.
- Volcomp settings were not properly indexed in the registry
for the Tech80 interface.
- Selecting multiple non-sequential features in Summary
Mode caused application errors.
- Some comments entered in dialogs were not being properly
converted to DMIS.
- The MODE command was exporting as MODUS in DMIS.
- File input/output was slow and serialization errors ocurred.
- Not all IGES surfaces were drawn if 2 trimmed surfaces
shared the same base surface.
- Probe simulation was not updating correctly in the graphics
window when online.
- Not all features in the graphics window allowed for selection
in a feature list.
- A second toolchanger on a Leitz machine was not loading
probes correctly.
- Vector point box select window frame radio buttons were
not functioning properly.
- Creating a HIT/BASIC via a Visual Basic script was not
including proper probe compensation.
- The minor axis dimension of an ellipse can now be displayed
with the "H" axis option.
- Cast cylinder diameter was not being calculated correctly.
- Application error happened when constructing a line with
segment data from a scan.
- Automatically inserting dimension axes was not inserting
them in the correct order.
- The Solidworks DCI wasn't picking up proper vectors on
all surfaces near the edges.
- Using a RECALL/VIEWSET command with the graphics window
minimized could cause execution to hang.
- Bad characters recieved during TCPIP communication with
a Leitz interface could cause a part program to stop executing.
- The vector of a midplane construction was not being properly
calculated.
- The OUTTOL dimension field was being created twice in
some instances.
- It is now possible to automatically acknowledge "Maximum
number of lines exceeded" messages during import of long
DMIS programs.
- Relative Measure was not properly adjusting the relative
vectors.
- Deleting extremely large blocks from a part program took
excessive amounts of time.
- Uninstall was causing application errors.
- Probe compensation was not working well in scanned tight
radii.
- Planes constructed from 2 lines caused application errors
if they were used in an alingment and the part program was
executed.
- The settings editor was not saving change curve color
values.
- True position total bonus of a slot was giving the sum
of the width bonus and the length bonus when the 2 were
equal.
- Application errors were generated when deleting scans
from the edit window using the DEL key.
- Best Fit 3D alignments were not being serialized properly
on saving a part program.
- An ability to install PC-DMIS without creating a backup
copy was added. To use this, the setup.exe command must
reference the case sensitive "/NoBackup" switch. (F:\pcdmis_install\setup.exe
/NoBackup)
- Tip rotations are now allowed while editing a command.
- The status of the "Use Theo" radio button was not being
saved.
- Constructing a circle from the intersection of 2 cones
was not working.
- Constructed ellipse curvature was not being calculated
correctly in the smaller radii.
- The install program was not overwriting read-only files.
- Several Probe Setup parameters were located under the
USER section of the registry instead of the MACHINE section.
- DMIS export caused application errors if the part program
contained null lines.
- The line vector for intersected planes changed during
the part program execution.
- There was a counter/hit mismatch while using the Mitutoyo
Bright interface.
- Assignment commands were not showing in Summary Mode
of PC-DMIS Pro.
- Offline linear open scans did not generate properly.
- UV scan simulation with SP600 did not emulate touch trigger
probing methods.
- The Key-In dimension tolerance sign was alternating on
subsequent executions.
- Different Z values were obtained for the position of
the ACR1 tool rack when qualifying with stylii of differing
sizes.
- Roundness was not showing the report deviation symbol
correctly if the it was created after a true position dimension.
- Microsoft code was causing toolbar data file to become
corrupted resulting in various errors.
- The Edit Window was not refreshing properly and sometimes
drawing blank.
- Temperature errors occurred when using temperature compensation
with Farenheit units.
- DMIS commands which fail to translate will now appear
as comments in the part program.
- Multi-lined text queries were not working correctly on
import.
- The MOVE/ALL command was added to the PC-DMIS menus.
- Machine movement occurred when using pull-down tip selection
and MOVE/ALL was the last command in the part program.
- The MOVE/ALL command was not working correctly on machines
equipped with the Renishaw PHS.
- Cylinder construction from a basic cylinder scan calculated
the wrong diameter.
- A "Show Contour Plot" option for UV Scans was missing
in Hyper-Reports.
- DCI support was added for I-DEAS v10.
- Improvements were made to DMIS import to allow for contructions
to have the same name as one of its member inputs.
- The cursor position was disappearing during step-mode
execution.
- Some registry entries were modifying entries in the v3.25
pcdlrn.ini file.
- Answering "No" to update features after an alignment
was changed was causing an excessive time delay.
- AVAIL programs translated into PC-DMIS could have collisions
on circles that used relative measure.
- Selecting edge points near the edge of a SolidWorks DCI
surface wasn't returning normal vectors.
- Marking constructed features that were already marked
could have caused PC-DMIS to close.
- Microsoft code was causing duplicate entries to be created
in the gbarstate.dat file.
- Additional registry entries were created for applying
offsets calibrated toolchanger clearance moves.
- The B axis angle was not displaying in the Probe Readout
Window when using the Zeiss infinite wrist.
- DXF/DWG file 3D support was added.
- Clearance plane moves were not being executed between
autocalibrate instructions.
- Application errors were encountered when opening a new
command line with the Enter key.
- Automotive letter deviations were not always showing
correctly.
- True position dimensions were not correctly fitting to
datums on creation.
- The dimension axis letter "M" was not being exposed to
automation for distance dimensions.
- The probe offsets were being change following an SP600
lower matrix calibration.
- The Korean resources were not displaying text in some
object windows.
- The Direct CAD Translator for Unigraphics files was not
always working correctly.
- Temperature sensor errors with the Leitz interface did
not allow recovery.
- The contour plot of surfaces was displaying above and
below the surface so was not completely visible.
- Pressing OK multiple times to the Installation Complete
dialog could start multiple instances of PC-DMIS and furthermore,
application errors.
- Layer support was added for the ProEngineer Direct CAD
interface.
- A4 paper sizing was not working with Hyper-reports.
- Hyper-report output to A4 paper size was not sizing correctly.
- Autozoom in Hyper-reports was not always performing correctly.
- Some Unigraphics files were not importing with the Direct
CAD Translator.
- Calibration offsets are now adjustable in the registry
for the SCR600.
- Contour plots were mixing with CAD surfaces and not fully
displaying on top of the CAD surfaces in graphics display
window.
- The Settings Editor edit box is greyed out when the user
is not an administrator for machine specific settings.
- Constructed midplanes were not always creating the correct
vector.
- The Arm2 calibration for System-5 grippers was not working
correctly.
- Feature nominal data was changing after executing with
Ctrl+U following a cancelled Ctrl+U execution.
- Importing DMIS files could miss references to previous
alignment identifiers.
- UseOldInterpolatedCircularMoves was not a key that one
user changed and all users accounts recieved automatically
in the registry.
- Pressing the Cancel button in the execution mode dialog
calculated twice through the part program if a breakpoint
was defined in the program.
- Erroneous collisions were detected when placing 5-Unique
fixtures.
- Cast and Mid Line constructions were showing that they
were 2D.
- Graphics support was improved for the NVidia chipset
drivers.
- A space was added to dimension deviations when showing
the automotive deviation letters.
- After importing settings, the Settings Editor didn't
display the new values until it had been closed with OK
and reopend again.
- Trying to enter a new command line caused application
errors.
- String concatenation was not working properly.
- Manual probe qualification was disabled for analog probes.
- Some Catia files failed to be directly imported.
- The PH10M would crash on the ACR1 during rack calibration
at A90 orientations.
- The dimensions headings for straightness were not formatting
correctly.
- Strings containing a combination of \" were not parsing
correclty.
- A message was added to the install program to remind
users that the first startup of PC-DMIS must be done with
adminsitrator priveledges.
- Changing the default directory for the part programs
was not writing this to working memory.
- A part program that automatically calibrated a slave
arm toolchanger stopped with probe data not available errors
on a Lietz interface.
- The Unigraphics Direct CAD Translator now supports wireframe
and point entities.
- Not all nominal dimensions were being properly converted
when mirroring part programs.
- The file cdintf210.dll was not being deleted on installation
and caused problems with PDF printing.
- The Loop dialog allowed for entry of negative loop numbers.
- The registry entry for DEAWrist was not importing from
prior verions pcdlrn.ini files.
- Auto Notch graphical illustration was workplane dependent.
- The Probe Readout Window was unnecessarily disabling
most keyboard functions when it had focus.
- The Guess Mode icon was missing from the measured features
toolbar.
- A UseOldInterpolatedCircularMoves option was added to
the registry as a way to prevent some types of collisions
when using circular moves.
- PC-DMIS will now prevent entering dual-arm mode if a
part program is open on the Arm2 computer.
- An error message was displayed at the end of each installation
on Mititoyo machines.
- A System-5 column was being moved to the wrong position
at the end of gripper calibration.
- PC-DMIS generated application errors after System-5 rack
definition.
- The System-5 calibration angles were not being saved.
- The MODE and WORKPLANE commands did not appear in the
Edit Window when using PC-DMIS Pro.
- Changes were made to support Unigraphics NX 2.0 with
the Direct CAD Interface.
- The Leitz interface timer loop was running too fast after
being in terminal mode.
- THEO values that were variables would be recalculated
if the Find Nominals was enabled during execution.
- The error message indicating a failure to convert a scan
to points was incorrect.
- Opening a CAD window in a Hyper-report was not always
displaying the whole content of the Grafics Window.
- Auto Features using Find Hole did not export the Find
Hole type.
- On initial creation, the PFD printout of the Hyper-report
drew leader lines through other dimension boxes.
- Prompts in the status bar were not updating after a sufficient
number of hits were taken while learning auto features.
- It was not possible to edit an auto feature spacer value
to be negative in the Edit Window.
- Zooming on analysis views in hyper-reports was not saving.
- Leader lines were disappearing and re-appearing with
errors in Hyper-reports.
- The DMI extension was not available for DMIS file export
via automation.
- Basicscan circle was not saving the Auto Move status.
- External rotary table were not fully supported with the
DEA-rs232 interface.
- The TP20 was not supported on the Faro Platinum interface.
- Some System-5 registry values were not storing in the
proper locations in the registry.
- "An unssuported attempt was made" message came up if
you tried to build a fixture with French language settings.
- Several registry entry permissions were modified to better
support non-administrator users.
- The Mechanical 5-Unique system did not advance properly
through column placement.
- The default color for AS3 file displayed as blue in DataView
instead of black.
- Several accelerator keys were incorrectly available while
in operator mode.
- The Edit Window was incorrectly docked for operator mode.
- The Manual/DCC icon was greyed-out in operator mode.
- File | Close was added as a menu option for PC-DMIS Pro.
- Using the probe wizard did not save probe calibration
results.
- It was not possible to construct a circle from the intersection
of a cone and cylinder.
- CAD element identities that were only numbers could not
be properly referenced.
- Circle Auto Feature CAD coordinates were not updating
when an alignment was deleted.
- The graphics window display was not saved and restored
correctly on restart of a part program.
- Some machine registry settings were incorrect after a
new operator used PC-DMIS.
- The reporting format was not adjusting columns properly
for the indicated style.
- Machine movement was not smooth around a sphere during
probe qualification on LK machines.
- The alignment list box was not adequately sized to support
large alignment names.
- Execution was jumping over a CalibrateProbe command during
Step Mode execution.
- Only header information was being displayed in the Chinese
generated RTF files.
- Importing DMIS files missing report definition commands
caused application errors.
- The setting for TableAvoidXYZ was being stored in the
wrong part of the registry.
- The automatic refresh of the Fixturing UI was not working.
- Application errors occurred if F1 help was utilized while
in summary mode with anything highlighted in the expanded
tree other than the feature command.
- The SMX Laser was slow to record measurement points using
the Ctrl+H option.
- The Fixture Grippers radio button was unnecessarily being
made unavailable.
- When using PCDMIS PRO, the function for Fly Active with
Radius was missing from Setup Options.
- In the PC-DMIS Pro Edit Window, the commands MODE/MANUAL
and FLY/ON were not displaying.
- The start menu characters for a Chinese installation
were not correct.
- The Qualification Check option in the Probe Measure dialog
was not active if a non-motorized probe head was not present.
- A manual tool change evolution was not possible with
the Zeiss-GPIB interface.
- Stop button on Zeiss-GPIB machine did not interrupt program
execution.
- The ACIS DCI was not recognizing the CAD file units.
- The iterative alignment object had not correctly implemented
replace_ptr and use_pointer for m_loop_label and m_fixture_error.
- Switching a second toolchanger type after calibrating
a first toolchanger caused application errors.
- Printing a hyper-report from edit mode was not properly
sizing the graphics.
- Johansson specific programs were not being correctly
installed on Johansson machines.
- The Print to File setting was not being saved for the
default in new part programs.
- An option was added to force manually measured lines
to have the same vector as the learned feature.
- Stopping a program after statistics gathering started
would prevent statistics gathering in subsequent executions.
- Auto Cones can now be created without regard to the order
of CAD circle selection.
- Conicity (Roundness) was not being calculated correctly
for Auto Cones.
- The automation call for feat.GetInputID(index) failed
for scan type features.
- Hyper-reports saved as PDF files sometimes contained
bad data for decimal numbers.
- The DMO output word for NOMINL was incorrectly spelled
as NOMINAL.
- Hyper-reports generated application errors if they included
comments and the Show Commenst option was disabled.
- True Position deviation symbols were not showing in Chinese
inspection reports.
- The user defined page margins were changed if a hyper-report
was edited.
- Solid view graphics were scaling to 50% when copied to
the windows clipboard.
- The search path browse button was not working properly.
- An optional delay after rotary table movement was added
to improve measurement accuracy.
- Variables assigned to best fit planes were referring
to the measured plane at learn time.
- Negative symbols could not be entered into tolerance
fields of deg/min/sec format dimensions.
- Header and footer information was displaying with distorted
characters in Chinese.
- There was an error in the datum reference plane for the
PLN-PLN-CYL true position dimension.
- Executing a manual sphere offline jumped through the
hits without waiting for acknowledgement.
- The Probe Head orientation was made unique for each user
account when in Offline mode.
- Programs created prior to v3.5 using the FILE/READ_UPTO
command could not be opened since the delimiter character
was not required to be in quotes.
- Pressing and while in Summary Mode not only
sent the cursor to end of the program but also needlessly
expanded the last item.
- Hyper-report script error strings were long and slow
to load.
- The CAD Info window was not displaying CAD information.
- The SafeZMove was set to high causing the machine to
go out of bounds when executing a single column fixture.
- The tab order in the Fixture dialog was improved.
- It is now possible to confirm System-5 assembly values
with the Apply button.
- Some text labels in the German Fixturing dialog were
too long.
- Some information was not being fully displayed in the
the Fixturing dialog.
- Some command buttons were too small to contain the text
of German translations.
- Sometimes the recall statement did not show up in alignments
after importing a DMIS program.
- The part serial number was added to the registry as an
option for DMO output.
- Feature labels were not correctly turning-off when creating
dimension info boxes.
- FeatCommand.NumHits returned incorrect values for constructed
features.
- Communications were lost after a Stop and Continue during
execution on a Mitutoyo Bright.
- Measured and nominal data was changing when pasting commands
from one part program to another.
- The labels for UP and DOWN in German were not correct
in some dialogs.
- The Visible property of the Analysis Window object didn't
work properly.
- F1 on a feature in summary mode brings up wrong Help
dialog.
- The Settings Editor startup process was improved to reduce
startup time.
- Serialization errors were created after mirroring perimeter
scans.
- Opening and closing the Leitz terminal window could cause
PC-DMIS to become non-responsive.
- The R axis for points was dimensioning the probe radius.
- A circle could not be constructed using the BF Recomp
method.
- Use Theo for Auto Cylinders was not determining correctly
the diameter.
- The Angle2 Start and End angles for Auto Spheres were
being changed during a Y axis mirror.
- Mirrored part programs did not open in the default part
program directory.
- Cutting a feature set from PC-DMIS was causing application
errors.
- Dimension labels were not aligning correctly in the inspection
reports.
- Saving statistics to a file was not working if the file
was on a network computer.
- New translation libraries allow importing of Unigraphics
files that previously had illegal elements.
- "Show Out of Tolerance Only" was being incorrectly defaulted
for inspection reports.
- The Unigraphics direct CAD translator included the wrong
dll's.
- A dialog was added informing installers that Administrator
priveledges are required for installation as well as the
first startup of PC-DMIS.
- Edge point thickness was not allowing real number inputs.
- Messages to take sample hits were not displaying in German
resources.
- Dimension box widths were standardized in inspection
reports.
- The tool tip box was only showing up when the Edit Window
was closed.
- The Angle Between dimension was changing when opening
a part program created in a previous version.
- Improvements were made to the handling of the DEA bridge
axis convention on horizontal arm Leitz interface machines.
- The prehit distance for the ends of square slots was
incorrect.
- The DEAWrist registry entry was not being stored in the
correct registry section.
- The Angle vectors for Auto Slots were unavaible for use
in variables.
- Doing constuction override on a scan feature was causing
an application error.
- The CAD select dialog was remaining open after closing
the Auto Features dialog.
- Pressing Ctrl+M to store a move point inside a measured
feature ended the feature on a Sharpe interface.
- Operator Comments were not pausing execution for manual
features with a Sharpe interface.
- The dimension axis "V" was not properly aligning with
other dimension axes in the inspection report.
- The MM4 command for ON_ERROR/ALL was not translating
correctly when imported to PC-DMIS.
- The MM4 command RAD(...) was importing as RAD2DEG instead
of DEG2RAD.
- XYZ readouts on a DCC Sheffield machine were not updating
correctly.
- The MM4 command ON_ERROR/ALL; ABORTPROG was not translating
correctly.
- The SPC database was exporting the true position bonus
as a combined bonus.
- Breakpoints caused improper execution of tip commands.
- A trace statement that had been added into an IF block
that didn't have opening and closing braces would cause
breakpoints not to work.
- Some metric STEP files were importing in inch units.
- The Polar interface did not work with Inch mode programs.
- Random errors were generated when using a rotary table
with the Sharpe interface.
- Use CAD Provided ID's Flag was not working with the ProE
DCI.
- PC-DMIS wasn't saving manual rotary table information
when used with the Leitz interface.
- The Basic Axis Scan did not work on the common controller
if the OBSERVER was enabled.
- An F9 edit of a Vector Point was not updating the nominal
information if the location changed.
- Rotary table position status was not being updated on
startup of PC-DMIS.
- T nominal value dimensions were not mirroring correctly.
- Slashes were arbitrarily being inserted into the beginning
of PDF and printed reports.
- Angle Between dimensions were not including the tolerance
bar color in the reports.
- Angles expressed in DD:MM:SS were showing the deviation
twice in reports.
- Angles expressed in DD:MM:SS were showing the deviation
twice in reports.
- Angle Between dimensions were not being sent to the XSTATS11.TMP
file.
- BFRE Cones of the correct size could not be constructed
from scans.
- Communications with the SolidWorks DCI were improved.
- Using the Generate function to create a Linear Open scan
caused application errors.
- 3D Best Fit alignments to a single point did not work.
- Part program names created with illegal characters now
save the characters as underscores.
- Orbix error messages for the I-DEAS DCI were not being
searched for in the proper direcotry.
- Gbarstate.dat file corruption problems were resolved.
- The Settings Editor export function now defaults to the
same directory as the Settings Editor.
- XYZ counters stopped updating after execution of a part
program on a Zeiss-GPIB machine.
- Identical registry entries were being deleted on import.
- Dimension info displayed the wrong color when only one
of the dimension's axes was shown.
- The status bar units indicator was not update if the
program units were changed due to the import of a CAD file
of different units.
- An additional M1 axis was added for statistical output
to support Form and Location negative tolerances.
- STEP files were not displaying smoothly after import.
- The report format has been modified to allow dimension
bars to align vertically.
- Invalid file error messages appeared when no available
UG license was detected.
- A default Operator Mode windows layout was added.
- The ability to Quit out of a part program from Operator
Mode was added.
- The bar above a feature name was not printing if the
feature color was changed.
- Graphical analysis of Form was available in the Location
dimension dialog even if it wasn't part of the dimension.
- No cursor was available during the partial execution
of a part program that had breakpoints defined.
- Starting execution in the middle of a program did not
save statistics.
- It was not possible to manually stop and continue a scan
executed from automation.
- Constructed Inside Cast Circles always had and outside
diameter.
- Power Users can now store homing offsets for Sheffield
interfaces in the registry.
- Pasting a True Position dimension left the 3 datum records
empty in the edit window.
- Inappropriate machine movement occurred on emergency
recovery with the gripper engaged in a System-5 column.
- There is now real time updating of the System-5 rack
status.
- Command status was not know in the event of an emergency
during System-5 operations.
- Machine control parameters were not remaining constant
when switching from Manual to DCC during Sytem-5 operations.
- The DMIS DID command was not being translated correctly.
- Dimension box sizes in the inspection report were not
maintaining proper size.
- Rotary scan didn't work properly if the origin axis wasn't
Z+.
- The application was crashing if a corrupted or empty
probe file was selected during the DMIS import.
- The PRBTYP SP8 firmware command was implemented for using
the SP80 with Common Leitz firmware.
- Tilt and rotation imported incorrectly from DMIS files.
- The manual retract distance was not being properly reset
after and illegal touch error on LK controllers.
- The target vector was updating incorrectly for Round
Slots that were measured manually.
- The menu item for "Send Current Stats to File" did not
function after Execute Feature was used.
- Using the Old DEA interface, after finishing probe calibration,
the probe moved up, mostly in Z, until it hit Z limit and
errored out.
- Auto cylinders measured with pitch had actuals that were
the reverse of theoreticals.
- The DMIS File I/O command was appearing in summary mode
without an icon symbol.
- Check distance on find hole centering measurments was
increased to 115%.
- The probe radius was added to the calculation for the
check distance value.
- Executing subroutines with best fit alignments caused
application errors.
- Application errors happened when printing to DMO output
in dual-arm part programs.
- The VALUE/ command for tolerance actuals was not available
in DMIS support.
- Autofeatures derived from a basic hit did not support
the RMEAS/ABSOLUTE function.
- The INIT text was disappearing when switching to FINDNOMS
for Auto Circles.
- 3D Best Fit alignments gave bad results if there was
no CAD and IgnoreCadToPart=0.
- Posting a round slot to DXF/DWG was creating a square
slot.
- Incomplete Virtual-DMIS files caused application errors
on import to PC-DMIS.
- Feature labels that were hidden were re-appearing after
program execution.
- The default layout data files had been corrupted and
caused spurious application errors.
- Indications were added to the program printout to indicate
arm specific commands.
- Some scan types were not working on Leitz PMM machines.
- DMO has extra OUTPUT/FA(label) statements that were confusing
Quirl posts.
- A 3D best fit alignment to 4 points was not computing
correctly.
- Having the move check box active with a non-zero distance
was not compatible with the measurement repetition of any
CMT features.
- Unnecessary messages were generated when deleting large
blocks containing dimensions.
- Edit Window layouts were not saved if a user Quit out
of a program.
- Selection order was not always correct in list boxes
for features with a space in the name.
- End of page indicators were not being properly written
to RTF files.
- Rotation information could be deleted from MOVE/ALL commands
if the program was closed after inserting the command without
executing it.
- It is now possible to disable circular moves during calibration
through a registry setting.
- Graphical analysis was not correctly saving the number
of hit deviations displayed.
- True position deviation was not being calculated correctly
for perpendicular to a centerline.
- The path to the statistics database now allows 255 characters.
- 5-Unique fixture execution sometimes asked for the wrong
column.
- The preview window was not allowing changing of the theoretical
and tolerance information.
- Parasolids version 14 CAD files are now supported.
- Auto Select Columns for 5-Unique fixturing was not working
properly.
- A user-defined order for 5-Unique column placement on
the table is now avaliable.
- Improper prompting occurred for loading 5-Unique modules.
- Alignments created after loops in dual-arm part programs
could cause application errors.
- Application errors ocurred when rotating the PH9 on a
Johansson machine in manual mode.
- Executing programs with statistics commands unmarked
still prompted for "Okay to save statistics".
- Auto Selecting columns from the Fixture dialog caused
application errors.
- Dual-arm calibration of a System-5 rack was not working
correctly.
- The Arm2 gripper could not properly grab the column in
rack position 1.
- Arm2 System-5 settings were not being stored on the Arm1
computer.
- Air was not present when gripping column 8 for the first
time in a System-5 rack.
- Application errors occurred when calibrating a System-5
rack where only column 8 was defined.
- Tip angles were not always mirroring correctly.
- Find Nominals did not work properly for Auto Circle when
selecting from a Unigraphics DCI file.
- Support was added for I-DEAS version 10.
- Fixturing commands were not properly parsing long fixture
file names.
- DMO output files did not carry identifying names with
the tolerances.
- Responding too fast to an OK to Rotate PH9 message box
could cause PC-DMIS to hang with the Johansson interface.
- The same circle measured at 2 rotated positions did not
give the correct distance dimension when measured on a rotary
table.
- The first rotary table move was not always commanded
or prompted for manual tables.
- RTF file output was not maintaining consistent page breaks.
- Some DMO report commands were not being output correctly.
- System-5 column recovery was confusing the column heights.
- Executing external commands that used a forward slash
/ escape was not recognizing the slash.
- Roundness of Minimum Separation Cylinders did not have
the same maximum positive and negative deviations.
- The Mitutoyo GPIB interface produced error 706 after
taking a point during qualification.
- Multi-line comments were producing DMIS export errors
stating "Line too long."
- Dual-arm fixtures caused application errors when trying
to execute the fixture.
- A change was made to the faceting tolerance to improve
the rotation of Unigraphics DCI models.
- Manual DEA machines were not initializing properly.
- Vector Point find vector failed if the feature had metal
thickness.
- Problems during homing on the DEA F controller might
not necessarily force PC-DMIS to home the machine.
- Copying programs with hyper-reports could cause the hyper-reports
to be destroyed on execution.
- BFRE planes, lines, and ellipse were being created with
the active tip rather than the tip used to measure the input
featrues.
- Basic scans help was not available.
- A minimum size was added to the dimension fields in the
Edit Window Report Mode to improve readability.
- 45 degree chamfers could not be measured with Auto Cone.
- Application errors were generated when deleting a WORKPLANE/ZPLUS
command.
- Application errors ocurred after editing weights of best
fit alignment features.
- Editing a UV scan was not properly updating the graphical
image.
- The Home Offset for Sheffield machines was not always
being properly stored in the registry.
- Sometimes the Edit Window would first appear blank if
a program was opened that contained CAD data.
- There was a bad move point in the System-5 dual-arm calibration
after the first pickup of Arm1 on an Arm2 column.
- Compensation type was not being properly transferred
when upgrading a Mitutoyo Bright from v3.25 to v3.5.
- Application errors happened when deleting command lines
from the DMIS mode of the Edit Window.
- A default layout algorithm was added for the creation
of Point Info boxes in Analysis views.
- Feature labels that were hidden were re-appearing after
program execution.
- Expressions in comments were not being properly exported
in Visual Basic.
- Degrees/Minutes/Seconds format was not properly supported
in DMIS format.
- A new method of selecting Edge Points was implemented
when using IDEAS CAD files.
- Programs containing subroutines were being added to the
most recent programs list if the subroutine was executed.
- Zeiss-GPIB interface machine speed was extremely slow
between garages of a tool change cycle.
- Distance dimensions calculated from a constructed slot
were not correct.
- Simulated horizontal arm machines showed the wrong direction
of movement for the Y axis.
- Calibration check in an inch program failed for probes
calibrated in metric programs.
- The Unigraphics DCT was not displaying or translating
all CAD entities.
- Switching between languages was causing PC-DMIS to give
resource errors on restart.
- The Auto Features dialog contained the English string
"distance" while using German.
- An EnableEstatus argument was added to the registry to
allow real-time updating of the XYZ readouts on Sharpe32
controllers.
- Manual execution lists were not properly updating feature
names.
- Edge points were not being executed if the program contained
surface points.
- Scan dialogs did not limit the maximum scan increment.
- After canceling a scan execution, saying "No" to save
the scan was not working.
- Use of the Delete key sometimes produced application
errors.
- Nominal data for generic features was not being mirrored
correctly.
- Entering dual-arm mode causes an application error on
the Arm2 computer when Arm2 has a populated System-5 column
set.
- DEFGRF commands from Chorus DMIS are now supported as
comments.
- ACTL and THEO data did not correspond after a To Points
scan.
- Two ENDMEAS/ commands were being inserted at the end
of a manual To Points scan.
- Adding fixture assembly offsets changed the view in the
graphics window.
- Alignments were not always saving in the correct directory
structure.
- Editing in the Report Mode window was not functioning.
- DMIS ARRAY commands were not importing correctly for
use in PC-DMIS.
- Spherical control points in a Basicscan did not work
through automation.
- Deleting scan points in a scan used in a best fit alignment
would cause application errors.
- F9 editing of a LOADFIXTURE command with automatic mode
caused application errors.
- Changing assembly offsets would offset the probe graphic
from the machine graphic.
- The machine graphics did not correctly draw Arm2 probes
at the end of the Arm 2 ram.
- Some Unigraphics file surfaces were not being imported
correctly.
- Loading a dual-arm machine model was destroying probe
file offsets.
- The DMIS TRANS command was not importing correctly if
all 3 X, Y, and Z fields were not declared.
- Roundness (Conicity) for Auto Cones was not being calculated
correclty.
- F1 help was not showing correctly when using Chinese
resources.
- Sample points and feature points were being taken out
of sequence.
- Section lines in multi-section manual scans were being
displayed relative to non-aligned coordinates.
- DMIS import did not correctly associate multiple probe
angles to multiple probe files.
- Application errors occurred when selecting to create
a new program after first closing another program while
using the Polar interface.
- Error 10061 was generated when using the Catia DCI on
an IBM Unix station with Catia v4.2.
- TP20 probes were producing Probe Missed Part error messages
during execution on Mora Machines.
- F9 edit of cylinders and cones was not properly updating
feature coordinates when switching between polar and cartesian
coordinates.
- Axis identifiers were not being listed in PC-DMIS Pro
alignment commands.
- Conflicts in the TEXT/FORMAT command caused out of memory
errors while looping with some dimensions.
- After hitting auto on a Sheffield jogbox to stop the
CMM, PC-DMIS couldn't be recovered.
- Auto Cone was not calculating correct nominal angle values.
- Some dimensions displayed their dimension tables with
an extra column after the graph.
- It was not possible to print selected pages in a Hyper-report.
- Communications errors (code 780) were generated on the
Mitutoyo Bright interface.
- The Settings button was incorrectly being made available
during F9 edit of some scans.
- Mitutoyo Bright machines experienced errors a few minutes
after activation.
- Report dimensions boxes not wrap long dimension heading
lines.
- Execution Mode Options window didn't show the commands
for sample hits while using German resources.
- Faro Platinum arms will now have the motors started and
initialized if needed on startup of PC-DMIS.
- A pop-up menu is now available for hiding DES labels.
- Individual levels of a PC-DMIS generated AS3 files could
not be viewed in DataView.
- Analysis views could have shown two profile graphics
for one scan object.
- The Edit Window could become unusable after using the
window minimize/maximize buttons.
- Pressing F1 in the Settings Editor did not link to the
help file.
- Constructing a cone from scans that went from larger
to smaller diameter did not work.
- A marked set would not print after execution if the global
print option is selected.
- DMIS QIS variables are incorrectly placed into the output
as TEXT/OPER.
- Tolerance labels are missing from the DMO report after
import of a DMIS file.
- PC-DMIS incorrectly creating two FA outputs instead of
one F and one FA after importing a DMIS file.
- DMIS features can now be output with the dimensions instead
of when the features are measured.
- Manual 5-Unique gripper calibration was commanding an
incorrect move.
- The Delete Point key on the joystick did not delete points
in when creating a Corner Point.
- Emergencies on the DEA controller could not be reset
after cancelling execution of a program with breakpoints.
- Importing a DMIS array variable was appending an underscore
to the command argument.
- Selecting 2 System-5 C500 columns consecutively produced
application errors.
- Support was added for the TP20 on the Faro arm machine.
- Feature type identifiers were being duplicated in status
bar prompts.
- Constructed Intersected Lines showed a redundant length
field in the Edit Window Command Mode.
- Graphics window rulers had no numbers or markings.
- Deleting large sections of programs that included dimensions
could have caused application errors.
- Best Fit Recomp was not working for the current probe
on constructed spheres if the probe was different than in
the the original program.
- Find Nominals in Point Only mode took to long to process
with the Unigraphics, ACIS, and I-DEAS DCI's.
- Improvements were made in the speed of switching of language
resource files.
- File I/O statements were not translating properly from
Chorus DMIS to PC-DMIS.
- It was impossible to change the Probe Head Orientation
if a machine model was loaded.
- It was not possible to enter a new System-5 fixture on
the first try.
- Clicking on a System-5 fixture point name in the Fixture
Setup dialog cause application errors.
- The graphics portion of the dimensions in the hyper-report
were being cut off.
- Hyper-reports were not required to be closed prior to
re-executing a part program.
- Hyper-reports could be hidden behind the graphics window
after execution.
- The Preview Window was not properly updating.
- Mitutoyo GPIB settings were being altered when installing
PC-DMIS.
- Pierce CAD while in 3D Rotate mode did not work with
the Unigraphics DCI.
- Cast plane construction was not working.
- A checkbox of Average Errors was incorrectly displaying
in the Iterative Alignment Wizard.
- It was not possible to deselect a group selected wire-frame
circle.
- The CAD vector was not being used as the default vector
for Ellipses.
- Execution hung in offline dual-arm execution simulation
if machine models were loaded.
- Speed improvements were made to the Catia DCI.
- Application errors were generated when defining a dual-arm
machine graphical model.
- The SCANSPEED command was not properly implemented for
Leitz PMM controllers.
- Errors during the manual part of a manual/DCC tool change
would cause a need for the tool change cycle to repeat from
the beginning.
- Clearance plane commands were not being executed during
the learn process with a Sharpe contrller.
- While using 5-Unique fixturing, the Unload instruction
was not supported in Offline mode.
- Startup with the SMX Laser was not always completing.
- Dimension symbols were missing in PDF report files.
- The 5-Unique unload instruction was not supported Offline.
- The THEO value for the Quick Start Cir_2CirLn was displaying
incorrectly.
- When measure was checked, the surface point did not complete
execution.
- Auto-Trigger, Auto-Trigger Plane, and Distance to Target
with Auto Zoom between Feature types was not working correctly
with the Faro interface.
- Feature labels saved in viewsets were sometimes being
serialized without a location.
- While in a part program and unmarking manual features,
PC-DMIS unmarked LOADPROBE and TIP commands also.
- The Graphics Window was not remaining maximized when
switching windows layouts.
- The scan segment command did not update the cad coordinates
of it's start and end points as needed.
- The Leitz jogbox Print button will now force hits when
used with a fixed probe.
- The Leitz common interface did not manage rotary table
CLOCKWISE and COUNTERCLOCKWISE commands.
- PDF output was generating application errors.
- The TP20 sometimes generated errors when being changed
with an ACR1.
- Hyper-Reports were not working when saving backward to
a previous version format.
- Key-In dimensions were not being shown correctly in Auto-Reports.
- Opening a 2nd program from a different folder during
execution confused the search paths.
- Changes in the registry caused some settings to be deleted
if PC-DMIS was not installed with administrator priveledges.
- The XYZ trihedron is drawing upside-down before first
alignment.
- The PDF print drivers were updated to resolve various
file generation problems.
- Command line switches were added to the PC-DMIS installation.
(/D, /NB, /SF)
- Generic planes were not being mirrored properly.
- Check boxes selections in the Probe Calibration Utility
are now maintained after closing.
- Cones constructed from scans were not always working
due to bad initial scan points.
- Center scan was not working properly.
- The Johansson interface did not work without a PH9.
- The Iterative Alignment Start Label didn't accept a custom
label name.
- Add-Ins toolbar was not available on toolbar shortcut
menu.
- The default rotation axis for iterative alignments was
not always being assigned properly.
- 3D rotate while executing scan caused application errors.
- The Automatically Adjust Probe Head Wrist General SetUp
Option caused an "Illegal tip" error message.
- Find for a known sheetmetal vector was not working if
a sheetmetal thickness was used.
- The Unigraphics Direct CAD Translator was not importing
all wireframe entities.
- Program coordinates would be corrupted if the program
recalled and external alignment that could not be found.
- PC-DMIS did not warn Pro-E DCI users when the original
file no longer existed and PC-DMIS was going to use the
original tessellated data.
- Toolbars shifted when changing desktop layout parameters.
- Direction points could not be properly defined during
learning of Quick Start measured planes on manual interface
machines.
- The isometric view was changed to be a true isometric
view.
- Attempting to unload a System-5 fixture could have caused
an application error.
- Selecting CAD labels did not select features in the features
list of construction dialogs.
- If the selected statistics databased did not exist, a
default database was not being used.
- The cursor was not properly positioning after manually
entering a CASE statement.
- The Settings Editor was not correctly saving new values
if the editor settings were exported.
- The status of the Arm2 System-5 rack was not being communicated
to the Arm1 computer.
- When using a System-5 module that wasn't a sphere, the
vector fields in the setup dialog were not being disabled.
- Edge point only mode now supports only single point probing.
- Some IGES files were missing surfaces after import using
AlternateIGESImport.
- A PH9 was not rotating correctly during program execution
on a System-5 equipped machine.
- PC-DMIS was not considering all possible hole locations
for placement of 5-Unique mechanical columns.
- A new registry setting allows the Sharpe32Z controller
to update XYZ counters if the enable button is depressed.
- Paper size was not a Hyper-report property.
- PC-DMIS changes a computer's local settings to use a
dot for the decimal separator and then restores the local
settings when PC-DMIS exits.
- Ctrl+E on a command worked only if no breakpoints were
defined.
- OLE objects used in hyper-reports did not correctly create
the required compile.bas file.
- Iterative alignment did not work on manual Sheffield
machines.
- Show Screen Captures were not controlled by window layout.
- Saved Windows Layouts were not being saved properly while
in Summary mode.
- RTF files were always being saved as 8-1/2 by 11 paper
size.
- Unigraphics files that could not be created read the
entire file before giving an error.
- Generic constructed point failed in command mode.
- It is now not necessary to exit PC-DMIS to recalculate
the wrist map when switching program units.
- Layer colors of constituent faces in Catia files were
not being read correctly on file import.
- It was not possible to measure an ellipse without obtaining
nominal data from a CAD file.
- Automatic numeration of features has been improved.
- Searching for probe files in sub-directories with the
Global Used button in Probe Utilities for tip angles in
now possible.
- It was not possible to break program execution when in
an endless loop.
- Some unnecessary files were being left on a computer
after an uninstall operation.
- Circular moves have been implemented for the Mitutoyo
interface.
|
|
Back to Top
Occasionally files for supported machine interfaces are changed
or added outside of the normal PC-DMIS version release parameters.
Follow this
link to download any updated or new interface files for
PC-DMIS Version 3.5 MR2.
To install an interface file:
- Follow the link above and download the .dll file to a
directory of your choice.
- Rename the DLL file to interfac.dll.
- Place interfac.dll file into the directory where you installed
PC-DMIS.
- Use PC-DMIS as usual.
|
|
Back to Top