Version 3.2

[Dividing Line Image]

Version 3.2 has been released to the public.

Contents:

[Dividing Line Image]

System Requirements

To Install and use PC-DMIS you will need:

  • Windows Operating System (Win95, Win98, Me, or Win2k supported). (Recommended Windows NT).
  • Pentium II Processer, 400 MHz or Higher IBM-compatible computer (Recommended Pentium III with 800 MHz or equivalent).
  • Minimum 64 MB of RAM (Recommended 256 MB of RAM).
  • A hard disk drive with 100 MB of free disk space (Recommended 200 MB).
  • 9.0 GB Hard Drive (Recommended)
  • A VGA or higher resolution monitor (Recommended 16M-color.
  • Graphics card with OpenGL support (driver that supports OpenGL) with a minimum 8MB ram (Recommended 32 MB RAM, hardware accelerated Transform and Lightning)
  • CD-ROM (Required).
Depending on your specific needs, the recommended system specifications for this version of PC-DMIS may be much higher. Be sure to consult with your PC-DMIS distributor to find out the type of computer system you will need in order to run this software at its optimum capability.

 

Back to Top

[Dividing Line Image]

Product Summary

PC-DMIS for Windows is a full-featured, geometric measurement package. It translates the high-level commands required to measure parts into the detailed steps necessary to drive a Coordinate Measuring Machine (CMM). PC-DMIS for Windows incorporates Microsoft's Windows interface to create, as well as execute part programs. The user can easily begin the measurement process by taking advantage of the drop-down menus, dialog boxes, and icons. The versatility of PC-DMIS' interface also provides an easy way to customize the software to meet the individual specifications.

The Primary goals driving the design of PC-DMIS for Windows were flexibility and user friendliness. To meet these goals, PC-DMIS provides a flexible environment allowing for real-time error correction of part programs, as opposed to the long, tedious debugging process of other geometric software packages. It is dimension oriented to reduce the need to analyze and interpret the results of the CMM measurements. The techniques used for the part programming on a CMM are straightforward and, with practice, systematic.

Back to Top

[Dividing Line Image]

New Features & Enhancements

Download the list of new features & enhancements in .doc format. New Features:
  • Saving Hyper-Reports in an External File. Hyper-Reports can now be saved externally and automatically in *.pdf format. The Adobe Systems Acrobat Reader is free program which will have to installed on the user's computer to view these files.
  • Summary Mode Window (Block Execution). This is a new tree view window of the part program has been created in the in the Edit Window.
  • Direct CAD Interfaces. Available now are direct import capabilities for use with Catia, Unigraphics, Pro/ENGINEER, I-DEAS, and ACIS. (These were previously available in the limited test release of Version 3.1.)
  • 3D Grid Lines in Graphics Window. An overlay of the CAD model can be created which is representative of body axis lines for better representation of measured features.
  • Mode Toolbars. Quick access toolbars were added for dimensions, constructions, auto features, and measured features. Display of these toolbars is optional.
  • Automatic Label Positioning (Setup Option). Labels for features can now automatically be spaced around the borders of the graphics viewing area rather than only attached to the feature where initially created.
  • Text Box Mode - When utilized, a right mouse click on a feature in the graphics window will display a menu of various options for reporting and editing.
  • Report Mode Window Graphic Tables - A new method of reporting can be utilized to generate more organized reports.
  • 321, Iterative, and Probe Calibration Wizards - These wizards will quickly and easily assist the programmer in some of the more complex evolutions of PC-DMIS. It is also possibly for users to create their own wizards.
  • Sheet Metal Guess Mode - In previous versions of PC-DMIS the operator could measure the part and create features with the nominal values based on the closed same type element in the CAD model. This same capability is now available with auto-features (sheetmetal).
  • Preview Window for Manual Machines - Though possible to be used also with DCC machines, the primary benefit will be for operators of manual machines who are not necessarily at the computer workstation when measuring features and desire to see a preview of the results before inclusion of a feature in a program.
  • Support of CV-100 Video Probe - This new video probe developed by Brown & Sharpe and CMT can now truly measure and calibrate in 3 dimension rotations and is fully functional with a toolchanger.
  • Support for CW43 & CW43Light 3 Axis Wrists - A new design for Brown & Sharpe infinitely indexable wrists includes a 3rd rotation axis for optimiztion of measurement when using the CV-100 video probe.
  • Brown & Sharpe Remote Panel Management - For large gantry and horizontal machines which may make more convenient to have a remote operating station, the Brown & Sharpe remote panel is fully supported.
  • Prompt Mode for Edit Window Output - When activated, at the end of execution, the operator can be prompted for naming and saving of report files.
  • Attach External Program - Allows for the use of results from another program or direct execution of a second part program.
  • Coaxiality - The coaxiality dimesion has been added. (Previously available in version 3.1 test release.)
Enhancements:
  • New Text Box Design. The new design will allow for better organized graphical reports and optimization of the graphics display area for graphical analysis.
  • Use Datums Mode in True Position. Operators can now quickly specify primary, secondary, and tertiary datums with proper material condition modifiers without the need to construct additional alignments.
  • Dynamic 3D Rotation Modes - Based on using a combination of holding down the Ctrl key and the right mouse button, it is possible to obtain a better more dynamic rotation of the CAD model while maitaining model scale.
  • DMIS 4.0 Support - Import and export of DMIS version 4.0 programs is completely supported.
  • Setup Option in Probe Utilities - Provides easy access for setting clearance moves during qualification, management of qualification results, tolerance values for newly generated result warnings, and assists with probe file management.
  • Multiple Tool Changer Support - In many CMM installations, it has been desirable to use more than one tool changer or even more than one type of tool changer. These applications are fully supported. . (Previously available in version 3.1 test release.)
  • Enhanced I/O Management for DEA Firmware Controllers - The necessity of accessing the pcdlrn.ini file for making changes to operation of controller options has been significantly reduced for these controllers.

Back to Top

[Dividing Line Image]

Version 3.201 Enhancements and Fixes

Download this list of new enhancements and bug fixes in .doc format. Enahancements: Fixes:
  • The on-line help contained a bad example of the format required to import an XYZ file. Fixed: 06/10/00.
  • The automation object for Auto Round Slot was returning information for an Angle field which should have be the Slot Vector field. Fixed: 06/09/00.
  • Attempting to import a Pro/Engineer DCI file would give a Could not Create CAD File error. Fixed: 06/09/00.
  • Programming offline with a rotary table was not properly updating the probe graphics when creating Auto Features. Fixed: 06/09/00.
  • Selecting a block of commands in Summary Mode and then right-clicking the mouse was deselecting the block. Fixed: 06/07/00.
  • Obtaining the hit reference data for a constructed feature from Automation was not possible. Fixed: 06/07/00.
  • Setting precise depths on surfaces that did not have boundaries in the vicinity of the mouse click was not working well. Fixed: 06/06/00.
  • Executing a program which printed a Hyper-report would ignore printing of the inspection report. Fixed: 06/01/00.
  • Constructing a plane from points could give a math not converging error. Fixed: 06/01/00.
  • Some labels were missing in Auto-Features dialogs associated with using the CV-100 Video Probe. Fixed: 05/25/00.
  • There was no difference in the Summary Mode window between Master and Slave arm commands. Fixed: 05/31/00.
  • Tool changes executed inside a loop with the CV43Light toolchanger were not changing with the correct slots. Fixed: 05/31/00.
  • Creating a scan with Measure checked could cause and application error. Fixed: 06/11/00.
  • Opening programs with large numbers of text boxes could take excessive amounts of time. Fixed: 06/02/00.
  • Trying to access the Print Setup in the Edit Window was giving an unsupported operation error. Fixed: 05/31/00.
  • The Find Hole procedure was not completing the Read Position function on LK machines. Fixed: 06/11/00.
  • The Find Hole procedure was changed to include allowances for RMEAS features. Added: 06/02/00.
  • Importing a DMIS file was not marking unqualified tools with an asterisk (*). Fixed: 05/23/00.
  • Tool changes would occur only if the LOADPROBE and TIP commands were marked. Fixed: 05/23/00.
  • PC-DMIS graphics were very slow when executing 3D rotations. Fixed: 05/30/00.
  • Auto-Report was not working if Auto-Zoom was not used. Fixed: 05/24/00.
  • After setting up and calibrating the CW43L tool changer for the slave machine using the master in dual-arm mode, when it takes the TOOLCS.DAT file and propagates it over to TOOLC.DAT on the slave machine, the file gets corrupted in the process and is not usable. Fixed: 05/20/00.
  • After error mapping a slave wrist using the master computer in dual-arm mode, once you shut down the slave you will get an application error when you try to restart the slave. Fixed: 05/20/00.
  • While in Summary Mode, selecting Ctrl+End was not placing the cursor at the end of the part program. Fixed: 05/24/00.
  • If a RECALL/VIEWSET command followed a MOVE/CLEARPLANE command, clearance planes would be set to off. Fixed: 05/18/00.
  • If you select options, analysis, and then make the graphical multiplier 200 (for instance) on a dimension and then apply, you could see the huge arrows appear on the screen to indicate the deviation of the points. If you then reselect options, analysis, and then make the graphical multiplier 1 (for instance) and then apply, you would see the arrows added to the screen but the arrows representing the 200 times multiplier remained. Fixed: 05/19/00.
  • Using the Iterative Alignment wizard was having problems with feature selection when measuring features after starting the wizard. Fixed: 05/19/00.
  • 206011 After setting clearance planes, they could be turned off by creating an Auto-Feature. Fixed. 05/25/00.
  • Problems in the execute loop would prevent normal execution of features and programs with probe rotations. Fixed: 05/18/00.
  • The DmisPart.Add automation function was not returning a value. Fixed: 05/22/00.
  • Crashing during the first hit of a scan was attempting to continue with on-error error recovery. Fixed: 05/19/00.
  • The Print Setup dialog accessed from the Edit Window had to much priority. Fixed: 05/17/00.
  • Saving a report in *.pdf format was saving the files with a *.rpt extension. Fixed: 05/17/00.
  • Programs containing large numbers of info boxes in the graphics window could take a long time to open or manipulate graphics. Fixed: 06/02/00.
  • Calibrating the rotary table could cause probe crashes if the probe vector was not opposite that of the calibration tool. Fixed: 05/19/00.
  • Starting PC-DMIS and going into Options | Rotary Table Setup | Calibrate, would give the message, "An attempt was made to access an unnamed file past its end." Hitting OK would continue normally. Fixed: 05/17/00.
  • The Find and Replace function was not finding and replacing references to a feature which contained feature extensions (i.e. F1.X, F2.HIT[1]). Fixed: 05/22/00.
  • Marking a block and executing from Summary Mode was not executing all features in the block. Fixed: 05/17/00.
  • Clearance planes were not working properly when inserted between scans. Fixed: 05/16/00.
  • The icons created in the program group aren't being pathed correctly to the proper files. Fixed: 05/19/00.
  • Dimensions were not being formatted properly in the inspection report. Fixed: 05/24/00.
  • Not all dimensions were being included in the inspection report at the end of execution. Fixed: 05/24/00.
  • In a hyper-report, it was not possible to turn off either the Feature ID or Dimension ID on a dimension Info Box. Fixed: 05/16/00.
  • Doing a Fixed Delta scan with the direction vector set to 1,0,0 and clicking Create could produce an application error. Fixed: 05/17/00.
  • Inaccuracy is created in wrist mapping when calibrating a wrist from a program that is created in a directory different from the PC-DMIS base directory. Fixed: 05/16/00.
  • In Summary Mode the True Position dimension did not include the DEVANG. Fixed: 05/16/00.
  • After an abnormal shutdown of PC-DMIS (such as an application error), not all threads of PC-DMIS were being terminated which allowed users to think they were online after restarting but they actually weren't. Fixed: 06/11/00.
  • Hyper-Reports had problems displaying dimension info boxes when the new graphical dimension format was enabled. Fixed: 05/16/00.
  • The DMIS command for MESVEL was not being converted correctly to Touchspeed. Fixed: 05/xx/00.
  • Entering settings in the Probe Setup dialog while in a metric program was creating a units conversion problem. Fixed: 05/15/00.
  • The probe calibration wizard was not functioning correctly. Fixed: 06/08/00.
  • Some ACIS file would have problems when displayed in PC-DMIS. Fixed: 05/16/00.
  • LOG/IN and LOG/OUT commands were included for use with the SMX Laser Tracker. Added: 06/06/00.
  • Dark Level and Home commands were added to the SMX wake-up function. Added: 06/06/00.
  • Changing colors in the Analysis Window or the Main Graphics was not redrawing the graphical analysis with the new colors. Fixed: 05/15/00.
  • Creating an angle point from CAD was not creating the correct surface vectors. Fixed: 05/31/00.
  • Creating a pattern offset which included a dimension was not updating the dimension according to the new features. Fixed: 05/31/00.
  • Vectors could be flipped on some scans. Fixed: 05/30/00.
  • Find Nominals on scans was not working in all cases. Fixed: 05/31/00.

Back to Top

[Dividing Line Image]

Version 3.202 Enhancements and Fixes

Download this list of new enhancements and bug fixes in .doc format.

Enahancements:

  • Via Automation, access to Feature Commands was changed from read only to read and write. Added: 06/20/00.
Fixes:
  • When starting PC-DMIS, programs which contained to identical labels could not be loaded. Fixed: 07/27/00.
  • Probe files which contained multiple autochange joints could not be changed correctly while using an ACCR1 toolchanger. Fixed: 07/27/00.
  • Collapsing the last feature in the Summary Mode window and then constructing an alignment was not maintaining the cursor at the end of the file. Fixed: 07/26/00.
  • String coercion of numerical strings would numerically add the strings vice appending the strings. Fixed: 07/24/00.
  • At the end of an offline Basic scan you could not press RETURN to insert commands on the next line. Fixed: 07/24/00.
  • After import of a DES file, selecting points in the graphics area was not always opening the Auto Features dialog window. Fixed: 07/18/00.
  • The test for convergence of constructed offset planes was too stringent. Fixed: 07/17/00.
  • Generating a Defined scan with measure checked and then saying Create after the Generate was completed was causing an application error. Fixed: 07/14/00.
  • Adding a sheetmetal thickness was changing the THEO value of the feature and not only the TARG. Fixed: 07/12/00.
  • The dimension labels were not being translated correctly for foreign resources. Fixed: 07/13/00.
  • Programs created in V3.0, which used the Gausian Filter, could cause application errors in V3.2. Fixed: 07/24/00.
  • DMIS export was not reading the SERV1.STP file to obtain the correct part sensor number. Fixed: 07/11/00.
  • The import of a DMIS cylinder was creating an Auto Cylinder with 0 rows of hits. Fixed: 07/08/00.
  • The wrist map would have slight errors if the map was created with a B starting and ending angle other than -180 to +180. Fixed: 07/06/00.
  • PC-DMIS Lite was import *.cad file when opening associated *.prg files. Fixed: 07/04/00.
  • If the STATS/ON command was not marked, STATS/UPDATE would not execute. Fixed: 07/05/00.
  • Changing the filter settings on a Basic Scan could cause an application error. Fixed: 06/30/00.
  • The Edit Window was not updating when converting a scan to points. Fixed: 06/27/00.
  • The File Open dialog would not display only prg and / or cad file types if PC-DMIS was not in English. Fixed: 07/01/00.
  • Best Fit alignment was not working when the number of input features was 3. Fixed: 06/22/00.
  • Starting a new program and measuring features was not automatically moving the cursor position to the end of the program. Fixed: 06/22/00.
  • After building a standard probe and adding two angles, pressing NEXT would give a run time error 9. Fixed: 06/21/00.
  • Importing a V3.0 program into V3.2 would cause errors in the True Positions dimensions. Fixed: 06/21/00.
  • The behavior of Find Hole was changed so that it doesn't do a Read Position when appropriate. (i.e. manual or offline execution) Fixed: 06/22/00.
  • DMIS RMES and VEC features which incorporated flow control statements were importing without the flow control objects. Fixed: 06/30/00.
  • The help file for the Basic Scrip toolbar was not showing the correct options. Fixed: 07/01/00.
  • The Feature ID text was missing from the tool box in hyper-view when features were not turned on in Report Mode Setup. Fixed: 06/19/00.
  • The Analysis View Window was not showing many items including Tolerance Lines, Drawing, and Grid. Fixed: 06/19/00.
  • Creating a scan with the combination of MASTER and RELEARN was allowing the scan to revert to FINDNOMS after completing. Fixed: 06/19/00.
  • Having Check Distance equal to 0 could cause problems when using the Find Hole function. Fixed: 06/20/00.
  • The TEXT strings in a DMIS file were being converted to all uppercase letters when imported to PC-DMIS. Fixed: 07/17/00.
  • Clicking on one of the XYZ fields at the bottom of the graphics window while PC-DMIS was on-line but a part program was not open would give an application error. Fixed: 06/13/00.
  • Creating scans with AutoCreate, AutoSave and Auto Graphical Analysis on while in Summary Mode would result in the dimensions being created in reverse order at the end of the program. Fixed: 06/20/00.
  • In Summary Mode, the field option was not present for the True or Complement toggle options for an angle between dimension. Fixed: 06/20/00.
  • AutoPH9 was attempting to select angles which were not in the qualified tip list. Fixed: 06/13/00.
  • Saving as Default the settings for the Edit Window position and size was not functioning. Fixed: 06/14/00.
  • Opening the Iterative Alignment Wizard was closing the active part program. Fixed: 06/12/00.
  • When trying to run Leapfrog the Ctrl-H was not registering a hit. Fixed: 06/24/00.
  • Tracefield data contained in a logo.dat file was not being printed in the inspection report. Fixed: 06/19/00.
  • When the edit window had the focus and a message box appeared to show some kind of message, the edit window would lose the focus. Fixed: 06/20/00.
  • Documentation of the new Find Hole method was missing. Fixed: 06/22/00.
  • Initialization for some Metrocom controllers was not being handled correctly. Fixed: 07/13/00.
  • The Probe Wizard would give a runtime error if after adding angles not A0B0 angle was added. Fixed: 06/26/00.
  • While in Measured Feature Guess Mode, creating a feature with a move point was not working. Fixed: 06/14/00.
  • The Tech80 interface could have some problems with accuracy due to the relationship of the probe file to the volcomp file. Fixed: 07/21/00.

Back to Top

[Dividing Line Image]

Version 3.203 Enhancements and Fixes

12 September 2000
Download this list of new enhancements and bug fixes in .doc format.

Enahancements:
  • 206596 Label is now automatically placed when creating a LOOP/START command from the Looping dialog. The label is not required. Added: 08/17/00.
  • 206405 Support was added for ACIS version 6.2. Added: 08/01/00.

Fixes:

  • 206772 If while running a program execution was canceled, it was impossible to select features in dimension dialogs. Fixed: 09/12/00.
  • 206701 Subsequent executions of part programs were not recalculating constructed surfaces. Fixed: 09/08/00.
  • 206700 Dimensioning of features in arrays was not indexing properly. Fixed: 09/07/00.
  • 206697 Recursive subroutines were not responding correctly to flow control statements embedded within them. Fixed: 09/07/00.
  • 206693 Subroutines were not updating variables correctly. Fixed: 09/07/00.
  • 206673 Right clicking on a feature ID and then choosing Hide Feature didn't hide the ID. Fixed: 09/11/00.
  • 206668 The edit dialog for auto features was not properly displaying the status of the Snap option. Fixed: 08/30/00.
  • 206665 A problem in the DEA interface would prevent programs from continuing execution after executing a basic script inside a loop. Fixed: 08/30/00.
  • 206657 The pitch value for an Auto Circle or Auto Cylinder could not be modified in the Edit Window. Fixed: 08/28/00.
  • 206654 Execution would hang on a MOVE/POINT command following an Iterative Alignment where the number of times to measure was set to ONCE. Fixed: 8/25/00.
  • 206653 Some V3.0 programs with statistics commands would not de-serialize in V3.2. Fixed: 08/25/00.
  • 206650 When in Operator Mode, Exiting to File Manager and the canceling the File Open dialog could give an application error. Fixed: 09/01/00.
  • 206649 Programs with loops which output statistics would include a start line as the last line of the xstats11.tmp file. 08/25/00.
  • 206647 Executing a program in step mode two consecutive times would cause and application error. Fixed: 09/07/00.
  • 206646 PC-DMIS would not consistently pause execution at breakpoints during step mode execution. Fixed: 09/07/00.
  • 206645 Summary Mode in the Edit Window was not recognizing the change for a change to best fit math type for an Auto Circle or Auto Cylinder. Fixed: 09/04/00.
  • 206643 Random application errors could be generated in Master/Slave mode if the slave computer was used while slaved to PC-DMIS. Fixed: 8/24/00.
  • 206641 Toggling the master/slave option for the command line arguments for a measured feature was not also toggling the ENDMEAS/ command. Fixed: 08/28/00.
  • 206634 Some older programs would open slowly in V3.2. Fixed: 08/23/00.
  • 206631 The Edit Window | Report | Print Setup option was not opening the appropriate dialog when using resources other than English. Fixed: 08/31/00.
  • 206629 After executing all hits for one arm where both arms of a dual arm system were required to measure the feature, hit prompting was not updating correctly. Fixed: 09/04/00.
  • 206620 Actual distance and angle properties of generic CONE features never updated. Fixed: 08/18/00.
  • 206616 Using programs created before V3.0 could have problems constructing cylinders from measured circles. Fixed: 08/23/00.
  • 206607 Creating generic features would create feature labels which were the same as the next already existing feature. Fixed: 08/18/00.
  • 206606 Attempting to calibrate tips using the Mark Used option with no sphere movement could result in no measurement. Fixed: 08/17/00.
  • 206605 & The radio button tab order assignment in the Generic Features dialog was
  • 206604 incorrect. Fixed: 08/30/00.
  • 206595 Reading values from a file and using them as variables was causing calculation errors. Fixed: 08/18/00.
  • 206586 Looping a program several times could cause a computer lock up. Fixed: 08/18/00.
  • 206582 Executing a program with alignments saved and recalled within a loop could cause several problems with alignment files and program serialization. Fixed: 08/28/00.
  • 206580 A user defined graphics window grid was not displaying properly. Fixed: 08/25/00.
  • 206575 Restoring an older version of PC-DMIS from backup would not work. Fixed: 08/28/00.
  • 206574 Print Preview of the graphics image would scale to the part graphics and not reference dimension info graphics. Fixed: 08/16/00.
  • 206577 Variables could have been incremented twice in master/slave programs. Fixed: 08/17/00.
  • 206572 Partial blocks of alignments and measured features could have been copied and pasted. Fixed: 08/22/00.
  • 206563 Offset lines were not mirroring correctly when mirroring part programs. Fixed: 08/14/00.
  • 206562 Running a master/slave program in DCC could cause an application error if a feature was measured using both arms. Fixed: 08/15/00.
  • 206557 Accessing the Print Setup menu option in the Edit Window would give an unsupported operation error when using a language resource other than English. Fixed: 08/30/00.
  • 206541 & The default values in Lietz controllers for rotary table speeds could prevent
  • 206507 program execution. Fixed: 08/29/00.
  • 206539 Application errors could be generated if Auto Create Dimensions was used while Auto Save Dimensions was turned off. Fixed: 08/31/00.
  • 206532 Slots constructed from two circles were not reporting the correct X axis location when dimensioned. Fixed: 08/03/00.
  • 206526 Vectors for manually measured planes on some Zeiss machines were occasionally flipping. Fixed: 09/05/00.
  • 206524 When you measure an outer round slot with a width less than the diameter of the probe tip, when the program reaches that point, it switches to manual mode, asking you to take the hits manually. Fixed: 08/01/00.
  • 206521 The proper Auto Feature dialogs were not available when using PC-DMIS Lite. Fixed: 08/03/00.
  • 206518 Posting out a Generic text file of scan points in 3.0 was not working. Fixed: 08/07/00.
  • 206515 Some Catia file name characters could not be read by PC-DMIS. Fixed: 08/22/00.
  • 206510 "SetFilterParams" did not match the UI and gives errors when attempting to try to use it. Fixed: 08/15/00.
  • 206496 Probe rotation would fail during execution on some LK machines. Fixed: 08/18/00.
  • 206491 If the VDA import filter was configured to read only the faces, all surfaces were not being properly excluded. Fixed: 08/04/00.
  • 206489 Feature array variables used as arguments in a BASICSCAN/LINE command were not working correctly. Fixed: 08/08/00.
  • 206476 Synchronization problems with Leitz controllers could cause bad hits to be stored. Fixed: 08/18/00.
  • 206470 The DES generated labels were not properly updating when switching selection from Edge Point to Vector Point. Fixed: 08/28/00.
  • 206434 The mean value for a profile dimension was not being calculated correctly. Fixed: 008/04/00.
  • 206424 Shading the surfaces of some STEP files could cause application errors. Fixed: 08/01/00.
  • 206421 Adding a sheetmetal thickness was changing the THEO value of the feature and not only the TARG. Fixed: 08/04/00.
  • 206413 The default value for the decimal place display in the Edit Window was not being correctly used. Fixed: 08/08/00.
  • 206409 Double-clicking the OK button in the probe utilities dialog for a slave arm probe could cause an application error. Fixed: 08/28/00.
  • 206383 Various problems were associated with using the PRINT command while using a PC-DMIS language resource other than English. Fixed: 08/28/00.
  • 206361 Printing a graphical view of a shaded image to which grid lines were added after shading would cause the grid image to print incorrectly. Fixed: 08/01/00.
  • 206354 The Click-Shift-Click operation was not working for highlighting sections in the Edit Window. Fixed: 08/24/00.
  • 206351 Execution on an LK machine could cause random systems lock-ups. Fixed: 08/18/00.
  • 206278 Perimeter scans had problems finding inner boundaries if the surface was rounded. Fixed: 08/28/00.
  • 206248 The Mark Used function was adding angles to the tip angle list that were not needed. Fixed: 08/29/00.
  • 205954 FILE/WRITELINE commands inside of loops were not writing the correct information. Fixed: 08/25/00.
  • 205814 Canceling installation at the time of receiving the setup dialog window would result in an application error. Fixed: 09/05/00.
  • 205721 Using F1 help for a UV Scan didn't take you straight to the UV Scan Dialog. Fixed: 08/09/00.
  • 201896 During step execution of a program, it was not possible to insert points into a feature. Fixed: 09/08/00.

Back to Top

[Dividing Line Image]

Version 3.204 Enhancements and Fixes

Due to an occasional problem with memory corruption in 3.203 release, Wilcox Associates, Inc. has released version 3.204 to Brown and Sharpe now that the problem has been identified and fixed.

16 September 2000
Download this list of new enhancements and bug fixes in .doc format.

Enahancements:
  • Draw analisys arrows as solid arrows. The analisys arrows on the graphics and analisys view display areas now can be drawn as solid arrows. the [OpenGLSettings] section in the pcdlrn.ini file contains an entry DrawArrowsAsSolid=1. If you change this to 0, then the old arrow style will be used. There is also an entry DrawArrowRadiusInMM=0.1. This is the max radius for the arrow shaft in millimeters.
  • Draw points as solid looking spheres. Points in PC-DMIS are now displayed as solid looking spheres. This can be controlled by the DrawPointsAsSpheres=1 setting in the [OpenGLSettings] section of the pcdlrn.ini file. If you change the default 1 to a 0, then PC-DMIS will use the old style drawing for points. You can also modify the DrawPointsRadiusInMM=1.0 entry to change the size of the spheres displayed. The default radius is 1 millimeter.
  • XYZ axis block is now drawn as a solid looking arrows.

Fixes:

  • 206816 The CAD image was being drawn incorrectly in the Hyper-view window if the mouse was clicked outside the window. Fixed: 09/15/00.
  • 206796 The F9 edit dialog for Parallelism was not working correctly. Fixed: 09/14/00.
  • 206784 The TR_TSENS error generated on Leitz controllers was causing operational problems in PC-DMIS. Fixed: 09/15/00.
  • 206519 Using Display Current Probe Position was causing the graphics to refresh too frequently with Romer machines. Fixed: 09/15/00.
  • OTHER Memory problems were experienced when rotating some CAD images with Dimension info boxes. Fixed: 09/15/00.

Back to Top

[Dividing Line Image]

Version 3.205 Enhancements and Fixes

24 October 2000
Download this list of new enhancements and bug fixes in .doc format.

Enahancements:
  • 206879 It is now possible to view CAD files in the graphics window while using PC-DMIS Lite. Added: 09/21/00.
  • 206842 New part programs are now saved to the default part program directory. Added: 09/21/00.

Fixes:

  • 207162 The default directory for saving part programs was not being properly set. Fixed: 10/21/00.
  • 207147 Inserting an Auto Feature which used the option AutoPH9 immediately after a tip command was not performing a probe rotation prior to measurement if the Measure option was checked. Fixed: 10/23/00.
  • 207145 When creating a True Position dimension for a non-circular feature, the DF axis was automatically being generated. Fixed: 10/21/00.
  • 207119 It was not possible to cancel the unnecessarily displayed error message, "Cannot find the Serv1.stp file in the PC-DMIS executable path. User must input values or copy file to proper path." Fixed: 10/18/00.
  • 207116 The END/DIMENSION command was not being created depending on the dimension options. Fixed: 10/18/00.
  • 207114 The targets and vectors of flipped features were not reversing with copy and pattern paste with a Flip Y. Fixed: 10/13/00.
  • 207093 The report window was not being automatically displayed after execution in Operator Mode. Fixed: 10/13/00.
  • 207092 The Edit Window was disappearing after execution in Operator Mode. Fixed: 10/13/00.
  • 207090 The Summary Mode Edit Window was mistakenly being made available in Operator Mode. Fixed: 10/13/00.
  • 207079 Variables used in feature nominals were not updating correctly. Fixed: 10/10/00.
  • 207076 Statistics data from dimensions at the end of a part program were not being included in the XSTATS11.tmp file. Fixed: 10/13/00.
  • 207075 BestFit2D alignments were not executing properly if an input feature was a scan set. Fixed: 10/23/00.
  • 207066 Redrawing the dimension info boxes when moving them could cause various performance problems. Fixed: 10/11/00.
  • 207054 The UsePointMethodFindHole option was causing probe crashes when measuring square slots. Fixed: 10/06/00.
  • 207053 Keyed-In dimensions were not being correctly converted when importing a version 2.3 program. Fixed: 10/06/00.
  • 207032 Rotary tables would continue to rotate with Sharpe interface machines after receiving movement errors. Fixed: 10/06/00.
  • 207026 Changes to the property sheet in a Hyper-Report were not updating analysis views. Fixed: 10/23/00.
  • 207012 Some datum modifiers could be changed to invalid commands. Fixed: 10/12/00.
  • 206984 Selecting the DCC option for probe calibration on a manual machine could cause calculation errors. Fixed: 09/29/00.
  • 206983 Right clicking on a feature in Summary Mode and then selecting delete was causing an application error. Fixed: 09/29/00.
  • 206979 Resuming DCC execution on an LK machine after going into manual override was not recognizing the correct retract distance. Fixed: 09/29/00.
  • 206974 Exporting a scan with the option for scan as points marked could cause IGES export processing problems. Fixed: 09/29/00.
  • 206973 Closing part programs used with a Numerex machine could cause application errors. Fixed: 09/28/00.
  • 206970 Automation was not accepting YES or NO as strings for initiating statistics. Fixed: 10/05/00.
  • 206958 It was impossible to enter numbers in the -Tol column of the inspection report that had a minus sign. Fixed: 10/04/00.
  • 206947 Constructing some features could cause an application error during execution. Fixed: 09/26/00.
  • 206941 The tolerance bar was starting in the middle of the tolerance bands for indication of tolerance used in dimension boxes for dimensions with a 0 nominal. Fixed: 10/16/00.
  • 206921 Pasting a copied object in the Edit Window would work correctly only two times. Fixed: 10/18/00.
  • 206911 Box selecting CAD elements was not working. Fixed: 09/22/00.
  • 206910 Imported CAD files were not always being saved in the correct directory. Fixed: 09/22/00.
  • 206907 The interrupt button was available on section scans with touch trigger probes and was not needed. Fixed: 09/22/00.
  • 206905 On-Error conditions were not functioning within subroutines. Fixed: 09/25/00.
  • 206904 Canceling execution of a basic script with a scan could cause a situation where the basic script call block could not be deleted from a program. Fixed: 09/28/00.
  • 206903 Not all aspects of scans were posting out in Basic format which prevented the scans from executing from a basic script. Fixed: 10/17/00.
  • 206902 The retract distance was always being converted to inches in the Edit Window with Elm interfaces. Fixed: 09/22/00.
  • 206899 Perimeter scans with touch trigger probes were not executing. Fixed: 09/22/00.
  • 206896 Mirroring a part program could generate an application error. Fixed: 09/22/00.
  • 206885 Choosing features in list boxes would result in location jumping in the list box if the feature selected was not on the first page of the list. Fixed: 09/21/00.
  • 206864 It was not possible to save to *.pdf file formats. Fixed: 09/22/00.
  • 206862 The Auto Features dialog window was reappearing after measuring the feature even though the show dialog feature was unmarked in the sheetmetal toolbar. Fixed: 09/27/00.
  • 206861 An unexpected hit on-error condition could cause execution to hang if the error branch was controlled by a variable. Fixed: 09/20/00.
  • 206854 Performing a flip vector on angle vectors in Auto Features dialogs could cause the angle vectors to normalize to 1,0,0. Fixed: 09/20/00.
  • 206849 The error message generated when Global Mark Used was unable to find a part program in a directory was incorrect. Fixed: 09/20/00.
  • 206848 Executing a feature which occurred before an alignment could result in an incorrect display of the feature coordinates in the Edit Window. Fixed: 10/05/00.
  • 206847 Opening the Temperature Compensation dialog with F9 was loading the default settings and not the programmed values. Fixed: 09/20/00.
  • 206845 Dimension Info boxes in the Hyper-report print preview window were not scaling correctly. Fixed: 09/19/00.
  • 206843 Best Fit Recomp for a constructed circle was not calculating correctly if the input feature was a constructed set. Fixed: 09/19/00.
  • 206841 Pattern offset was causing Target values of features inside a loop to be incorrect on the copied features. Fixed: 09/20/00.
  • 206840 The letters U and V were not being shown in text boxes for UV Scans. Fixed: 09/21/00.
  • 206829 Print preview was not correctly displaying graphics grid lines. Fixed: 09/20/00.
  • 206809 Default tolerances were not being used in new part programs. Fixed: 09/19/00.
  • 206805 Using deg.min.sec format for the angle dimensions, you couldn't enter a negative angle for the nominal or tolerance values. Fixed: 10/04/00.
  • 206804 It was not possible to correctly enter negative tolerance values if Minus Tols Show Negative was selected. Fixed: 10/04/00.
  • 206749 ShowProfileOptions in the pcdlrn.ini file defaulted to 1 during installation which caused Show Arrow Heads, Show Lines Between Measured Hits, Show Nominals, and Show Tolerance Lines to default to OFF. Fixed: 10/23/00.
  • 206738 Setting depth by selecting a CAD wire was not working correctly. Fixed: 09/28/00.
  • 206688 Some trimmed surfaces could be lost when mirroring IGES files. Fixed: 09/22/00.
  • 206675 The groups in VDA CAD files were not importing as layers in PC-DMIS. Fixed: 09/27/00.
  • 206663 CAD labels when displaying solid views were not displaying. Fixed: 09/22/00.
  • 206623 Partial calibration was not working on the Renishaw ACR1 autochange rack. Fixed: 09/27/00.
  • 206067 Changing the Hit Interval option in the CMM Interface Setup dialog was not saving this setting to the pcdlrn.ini file for Tech80 interfaces. Fixed: 10/11/00.
  • 206570 Leader lines for dimension info boxes were disappearing after the box was moved. Fixed: 09/25/00.
  • 206549 The Edit CAD and Delete CAD menu options were available when other dialogs were open. Fixed: 09/22/00.
  • 206546 False probe triggers acquired during manual probe rotation on a Numerex controller were causing bad calibration results. Fixed: 09/22/00.
  • 206457 Crash detection was not working during a rotary table move command. Fixed: 10/23/00.
  • 206338 The individual hits for Auto Features were not posting out in DMIS. Fixed: 10/05/00.

Back to Top

[Dividing Line Image]

Version 3.206 Enhancements and Fixes

12 March 2001
Download this list of new enhancements and bug fixes in .doc format.Download Fixes_3.206.doc

Enhancements:

  • 208069 The automation object "App.WaitUntilReady T" was added where T is the time in seconds to wait during program initialization to prevent startup errors. Added: 02/14/01.
  • 207811 Support was added for the offset joint knuckle styli extensions. Added: 01/23/01.
  • 207520 The TextBoxPaddingFactorInPercent option was added to the pcdlrn.ini to allow for the adjustment space between columns in text boxes. Added: 02/20/01.
  • 207434 The '-' can now be utilized for feature names when providing Feature ID's inside the Auto Features dialog. Added: 12/01/00.
  • 207421 Options were added to the pcdlrn.ini file to allow Unigraphics files created from assemblies to be opened. Added: 01/09/00.
  • 207311 The circular move option has been added for ellipses. Added: 11/22/00.
  • ------ Support for the CW43Lite toolchanger was added to the Leitz interface.

Fixes:

  • 208320 Performing a Ctrl+E while the cursor was on a Profile dimension was not executing the last dimension. Fixed: 03/08/01.
  • 208302 Generic Circles created inside loops were having their vectors changed when executed. Fixed: 03/05/01.
  • 208284 Remeasuring saved alignments caused unnecessary prompts to appear. Fixed: 03/08/01. 208279 The Set Search Path and Save directories for alignments did not coincide. Fixed: 03/02/01.
  • 208269 Pressing the Stop button during a TTP scan could cause execution errors. Fixed: 03/06/01.
  • 208268 Perimeter scans were not properly detecting some outer boundaries. Fixed: 03/06/01.
  • 208241 Pitch on Auto Cylinders was not measuring correctly. Fixed. 03/02/01.
  • 208237 BFRE Constructed Circles were not compensating for the probe diameter. Fixed: 03/02/01.
  • 208228 It was not possible to create multi-row manual scans. Fixed: 02/27/01.
  • 208220 Point Info and Dimension Info boxes were not being included in PC-DMIS Lite. Fixed: 02/27/01.
  • 208218 Attached part programs could report some dimensions with the wrong alignment. Fixed: 03/09/01.
  • 208186 The automation WaitUntilReady function was not functioning in all situations. Fixed: 03/06/01.
  • 208180 Choosing the Basic Scan | Center menu item was causing an application error. Fixed: 02/27/01.
  • 208179 An application error was generated during System-5 calibration when the arm engaged the column for the first time. Fixed: 02/20/01.
  • 208177 Execution was stopping after hyper-report commands which were generated after a print report command. Fixed: 02/21/01.
  • 208175 PC-DMIS was not completing the download of the machine parameters from PMM-C machines. Fixed: 02/21/01.
  • 208165 With Find Nom selected in the Vector Point dialog and a hit was taken, if the nominals weren't found, X, Y, and Z would all reset to 0. Fixed: 02/26/01.
  • 208153 Hyper-reports generated in v3.0 could not be opened. Fixed: 02/19/01.
  • 208150 Application errors were generated if hits were taken while the cursor was positioned on a feature theoretical command line. Fixed: 02/21/01.
  • 208148 Edit Window customized settings were not being saved as default. Fixed: 02/16/01.
  • 208143 Hyper-reports were not always generating during execution. Fixed: 02/22/01.
  • 208142 Editing the LOADPROBE command was not properly updating the probe offset information for feature calculations. Fixed: 02/20/01.
  • 208131 Vector points measured in subroutines were reporting in machine coordinates. Fixed: 03/01/01.
  • 208128 A CMM Not Responding message was incorrectly displayed when initializing Reflex machines. Fixed: 02/15/01.
  • 208127 The CAD image was not being drawn in hyper-reports. Fixed: 02/21/01.
  • 208126 Deleting True Position dimensions and scrolling could cause application errors. Also, doing an F9 edit of the dimension could change the theoretical values. Fixed: 02/22/01.
  • 208120 Not all objects in Hyper-reports were being created. Fixed: 02/19/01.
  • 208114 Pitch for outside cylinders was measuring in the wrong direction. Fixed: 02/13/01.
  • 208108 Accessing the autotrigger option would cause application errors in the Portuguese version. Fixed: 02/14/01.
  • 208101 The scale factor was not scaling properly. Fixed: 02/14/01.
  • 208098 Several menu options were being made incorrectly available when dialog windows were open. Fixed: 02/14/01.
  • 208096 Manualretract commands could cause slave execution to pause when used with Auto Features and Auto Create Dimensions. Fixed: 01/12/01.
  • 208095 The pitch value for Auto Cylinders was not being correctly applied. Fixed: 02/12/01.
  • 208093 Surface Points allowed the numbers 1 or 2 to be entered in the Init and Perm fields of the dialog even though only 0 and 3 were used. Fixed: 02/12/01.
  • 208084 Pressing Done on the slave arm jogbox could cause an application error after manually measuring a feature. Fixed: 02/12/01.
  • 208061 If Auto Load Hyper-Report was marked, the report would try to load after executing scans in learn mode. Fixed: 02/08/01.
  • 208050 Parking the two innermost columns of a System5 rack could cause a collision. Fixed: 02/14/01.
  • 208047 It was not possible to edit the name of a qualification tool. Fixed: 02/08/01.
  • 208046 After a partial execution in step mode, the last executed commands remained highlighted in black. Fixed: 02/12/01.
  • 208045 Creating a new program with a program name that already existed would cause an application error. Fixed: 02/08/01.
  • 208031 Saved alignments could only be used if the working program was in the PC-DMIS installation directory. Fixed: 02/08/01.
  • 208028 Automatic ordering of hits for features was inconsistent after editing. Fixed: 02/12/01.
  • 208020 Scan feature numbering could get out of sequence if using the X button to close the scan dialog. Fixed: 02/08/01.
  • 208011 Auto-reports did not allow more than 80 dimensions per page. Fixed: 02/19/01
  • 207988 Edited changes to a saved Analysisview were not being saved. Fixed: 02/09/01.
  • 207985 Exclusion Zones were not functioning. Fixed: 02/09/01.
  • 207983 The Show Options defaults in Analysis Views could not be saved. Fixed: 02/05/01.
  • 207982 Analysis depictions for roundness of minimum circumscribed and maximum inscribed circles were inaccurate. Fixed: 02/10/01.
  • 207972 When an inspection report was saved to an external file, the margins were ignored when it was imported into MSWord. Fixed: 02/12/01.
  • 207971 Circles edited to use the fixed radius option were not having the diameter calculated correctly. Fixed: 02/21/01. 207970
  • Dimensions were being separated by page breaks in the inspection report. Fixed: 02/13/01.
  • 207960 Initial calibration for the Arm 2 side of System 5 was causing the gripper to retract in Y- rather than Y+. Fixed: 02/14/02.
  • 207948 Probe rotation commands were not always being executed after a probe change after an execution pause and restart. Fixed: 02/06/01.
  • 207946 The constructed line dialog was not always depicting the correct 2D or 3D status of a line. Fixed: 02/02/01.
  • 207944 Auto Circles learned from CAD were not measuring in the correct locations. Fixed: 02/02/01.
  • 207941 Temperature compensation was incorrectly associating with the slave execution dialog during master/slave execution. Fixed: 02/06/01.
  • 207935 The application object was starting too soon when launching PC-DMIS from Visual Basic. Fixed: 02/08/01.
  • 207917 Changing the type of volumetric compensation inside PC-DMIS could cause an application error. Fixed: 02/01/01.
  • 207914 Overwriting an existing part program could cause an application error. Fixed: 02/12/01.
  • 207890 Foreign languages were not recognizing the separators in TEMPCOMP commands. Fixed: 01/31/01.
  • 207886 Problems were encountered when qualifying a probe with a tool not located on the rotary table if the table was not positioned at zero degrees. Fixed: 02/13/01.
  • 207874 Feature arguments were not being updated for the second feature passed into a subroutine. Fixed: 01/30/01.
  • 207855 The Previous button in the Probe Calibration Wizard was not functioning correctly. Fixed: 02/21/01.
  • 207850 It was not possible to change the resource language unless a part program was open. Fixed: 01/30/01.
  • 207849 Application errors were generated if an attempt was made to execute a part program which did not have a valid probe file loaded. Fixed: 01/27/01.
  • 207845 Master/slave program execution would hang on File/Open commands. Fixed: 01/29/01.
  • 207843 Copying scans and constructing lines from the copied scans was causing calculation and application errors. Fixed: 01/30/01.
  • 207841 Check distance was being calculated from the prehit point rather than the target point for some interfaces. Fixed: 01/29/01.
  • 207838 Starting PC-DMIS without a portlock was causing startup errors after reattaching the portlock. Fixed: 01/29/01.
  • 207833 Hit compensation was not calculating correctly in some constructed features. Fixed: 01/29/01.
  • 207825 Dimensions reported in the Edit Window referenced part coordinates. Fixed: 01/24/01.
  • 207823 Program execution was pausing after measure features in some programs. Fixed: 01/25/01.
  • 207821 Application errors were encountered when not calibrating all tips in a probe file. Fixed: 01/24/01.
  • 207819 Writing to files was ignoring spaces inserted in some fields. Fixed: 01/24/01.
  • 207817 Dimensioning 2D distances from a point to a plane was not giving the correct result. Fixed: 01/26/01.
  • 207813 Creating a part program in inches on a Sheffield cmm was causing several errors. Fixed: 01/23/01.
  • 207805 After editing a probe file for a wrist type probe, it would no longer be able to rotate. Fixed: 01/23/01.
  • 207802 After executing a program where a scan was converted to points, the points were not properly marking in the Edit Window. Fixed: 01/23/01.
  • 207798 The temperature compensation warning about changing machine specific parameters was not linked the compensation methods dialog. Fixed: 01/23/01.
  • 207789 The AddInputFeat function from automation was not recalculating the number of inputs. Fixed: 01/25/01.
  • 207784 Some elements of auto-reports were not being passed to successive pages in a multi-page report. Fixed: 02/17/01.
  • 207782 The Edit Window was losing focus if the message box which asked if a comment referenced a variable was displayed. Fixed: 01/22/01.
  • 207780 Opening the F9 edit dialog for a true position dimensions was rearranging the dimensional information when closed. Fixed: 01/23/01.
  • 207779 The Edit Window was not properly refreshing after execution of a basic script. Fixed: 01/29/01.
  • 207775 Dimensioning true position for a generic cylinder was not displaying the X, Y, and Z values. Fixed: 01/19/01.
  • 207762 Inserting temperature compensation commands from the setup dialog for the slave arm of a master/slave program was not working. Fixed: 01/18/01.
  • 207761 Opening an operator mode program which was already open was creating duplicate marked sets. Fixed: 01/17/01.
  • 207755 Collision detection was not working properly with UG files. Fixed: 01/30/01.
  • 207750 The features toolbar was reappearing when PC-DMIS was restarted after the toolbar had been turned off. Fixed: 01/16/00.
  • 207741 Application errors were generated when performing UV scans on models imported via Direct CAD interfaces. Fixed: 01/17/00.
  • 207739 Offset points were not calculating properly after execution and were losing data when imported from previous versions. Fixed: 01/22/01.
  • 207738 Printing a graphics image with the scale to fit option was not including the text boxes in the scaled sized. Fixed: 02/08/01.
  • 207736, 207730, & 207729 Several System-5 parameters were not being saved to the pcdlrn.ini file. Fixed: 01/18/00.
  • 207735 System-5 column recovery was not checking for columns already in the rack. Fixed: 01/23/01.
  • 207732 After changing module offsets, the changes weren't propagating through the fixtures. Fixed: 01/18/01.
  • 207718 Readpoints inside a loop could cause problems when canceling execution of a program. Fixed: 01/12/00.
  • 207717 Application errors were generated when creating 3D Angle Between and 3D Distance dimensions with the Display option. Fixed: 01/12/00.
  • 207715 The Linear Open scan type was not being made available to users of the Basic license of PC-DMIS. Fixed: 01/12/00.
  • 207710 Fast probing was being turned on when it wasn't specified as being used. Fixed: 01/10/01.
  • 207707 After qualifying a probe file using the Probe Wizard, the qualification status of the tips was not reflected in probe utilities. Fixed: 01/25/01.
  • 207706 After probe calibration was completed using the Probe Wizard, the LOADPROBE statement remained empty. Fixed: 01/25/01.
  • 207705 Probe calibration was not executing properly when using the Probe Wizard after previously opening Probe Utilities. Fixed: 01/25/01.
  • 207694 Certain spherical surface types could not be selected. Fixed: 01/09/01.
  • 207693 Probe rotation for the slave arm was not occurring correctly for moves inside a loop when the initial position was outside the loop. Fixed: 01/09/01.
  • 207690 Changing a circle from INNER to OUTER was not reflecting in the Edit Window values. Fixed: 01/15/00.
  • 207689 Editing the number of input features for a constructed feature could cause an application error if the dialog was afterwards opened and then closed. Fixed: 01/10/01.
  • 207686 5-axis scanning with the CW43 or CW43Light probe heads did not work. Fixed: 01/22/00.
  • 207679 ACIS SAT files which were dimensioned in inches were not importing with the correct units. Fixed: 01/15/00.
  • 207678 & 207663 Creating a UV scan would create points over non-existent surfaces such as holes. Fixed: 01/09/01.
  • 207668 The control points for constructed curves were in machine coordinates rather than part coordinates. Fixed: 01/10/01.
  • 207667 The DMIS TOL/PARLEL statement was not supporting the absence of the RFS argument during translation. Fixed: 01/04/01.
  • 207658 Customized report options were not being saved when changed while in Summary Mode. Fixed: 01/04/01.
  • 207657 Offsets for constructed elements were not being properly applied. Fixed: 01/04/01.
  • 207656 Findnoms was not working correctly when using the Catia DCI. Fixed: 01/09/01.
  • 207649 Square slots were not measuring correctly if a CAD=Part alignment was used. Fixed: 01/03/01.
  • 207642 Application errors were encountered when creating new fixture names from the Fixture Setup dialog. Fixed: 12/22/00.
  • 207636 The Iterative Alignment Wizard was not working with 3 Auto Circles. Fixed: 12/22/00.
  • 207635, 207599, 207524, & 207522 The hasp install program was not working properly on installation. Fixed: 12/21/00.
  • 207633 File | Save As was properly updating the Title Bar but was not updating the Active Part Program window. Fixed: 12/22/00.
  • 207631 System 5 column recovery was not correctly reading the gripper position. Fixed: 12/28/00
  • . 207626 The XYZ values of fixtures were not displayed when doing an F9 edit on the a Loadfixture command. Fixed: 12/21/00.
  • 207619 Negative values could not be entered in the XYZIJK edit boxes in the Create Fixture dialog. Fixed: 12/21/00
  • . 207618 Tip data used for calibrating System 5 / 5-Unique fixtures was not being saved. Fixed: 12/28/00.
  • 207617 The CMM would go out of stroke in Y during System 5 DCC column calibration. Fixed: 12/20/00.
  • 207615 Fixture alignments were creating confusion regarding the currently active alignment system. Fixed: 12/22/00.
  • 207613 Thickness values were not being properly applied when measuring vector points in Point Only Mode. Fixed: 01/03/01.
  • 207610 Analysisview commands, which contained information for non-existent (deleted) features, were generating application errors. Fixed: 12/20/00.
  • 207609 Several communication problems were encountered during calibration of Faro machines. Fixed: 01/05/01.
  • 207606 When using a UV grid, points were placed out in space when holes exist in geometry while using a file from the UG DCI. Fixed: 01/09/01.
  • 207605 The Iterative Alignment Wizard was not closing on Finish. Fixed: 01/25/01.
  • 207603 Disengage drives mode was not working on the Leitz interface if a PH9 type probe file was loaded. Fixed: 12/20/00.
  • 207602 While in Summary Mode and scanning with Single Point, the points were not being created in Command Mode. Fixed: 01/03/00.
  • 207600 Leapfrog was not working during execution. Fixed: 01/03/00.
  • 207598 The DMIS PROMPT/ command was not being correctly translated as a COMMENT/INPUT in PC-DMIS. Fixed: 12/20/00.
  • 207597 The DMIS FEDRAT/PCNT command was always being translated to mean a percentage of maximum touchspeed. Fixed: 01/02/01.
  • 207595 TIP commands were not being properly mirrored in part programs. Fixed: 01/04/01.
  • 207592 If a file read error was encountered, canceling execution from the Execution Mode dialog would cause an application error. Fixed: 12/19/00.
  • 207584 Application errors were encountered if you did an initial calibration after incorrectly specifying the same calibration tip as the safe tip. Fixed: 12/19/00.
  • 207581 The prompt during initial calibration on the slave arm incorrectly prompted the user to "put col #26 into slot #1". It should have said to put it into slot #26. Fixed. 12/19/00.
  • 207576 DEA volcomp was not properly implemented in the Leitz interface. Fixed: 12/21/00.
  • 207574 Shading some IGES files could cause application errors. Fixed: 12/20/00.
  • 207566 Calibration of an SP600 with 12 hits and 3 rows was not working properly. Fixed: 12/22/00.
  • 207562 Pattern pasting in the X or Y workplanes could show small theoretical errors due the vector compensation of the probe. Fixed: 12/15/00.
  • 207560 Changing probes were causing problems with clearance planes. Fixed: 12/14/00.
  • 207556 Undesirable optical illustrations resulted from selecting the Tip List when the cursor was on a Loadprobe command. Fixed: 12/14/00.
  • 207553 Keyed-In dimensions were not being sent to the XSTATS11.tmp file. Fixed: 12/14/00.
  • 207551 The cut vectors in scans which were copied and pasted were not remaining the same. Fixed: 01/03/00.
  • 207550 The hit data for cylinders measured with a pitch was incorrect. Fixed: 12/14/00.
  • 207549 The Edit Hit data for features, which weren't executed following execution of an alignment, was incorrect. Fixed: 12/14/00.
  • 207547 Guess Mode was not being defaulted when accessing the measured features toolbar. Fixed: 12/15/00.
  • 207546 Editing a feature ID after copying and pasting could cause the cursor to reposition incorrectly. Fixed: 02/02/01.
  • 207539 The icon for the 3D Angle dimension was not optically appealing. Fixed: 12/13/00.
  • 207535 Entering a basic script file name to be executed could create a filename with a .bas.bas extension. Fixed: 12/21/00.
  • 207530 If a portlock was programmed with PC-DMIS Lite, the interface type did not show up when executing Custprog.exe. Fixed: 12/21/00.
  • 207528 Editing the text following a CASE/ statement and then pressing Enter was opening a new line and then deleting the line immediately below. Fixed: 12/22/00.
  • 207525 The AutoChangeStandAloneDelay value was affecting tool changes with the ACR1 toolchanger when using serial control. Fixed: 12/15/00.
  • 207518 Analysis views were not saving and displaying info boxes correctly. Fixed: 01/16/00.
  • 207507 The install program was not working in the beta version. Fixed: 12/08/00.
  • 207504 Calls to non-existent basic scripts would cause PC-DMIS to exit or an application error. Fixed: 01/03/01.
  • 207498 The ability to run the pcdcat.* file from Catia workstations was implemented. Fixed: 01/04/01.
  • 207496 The target coordinates for High Points inside a loop were being corrupted. Fixed: 12/06/00.
  • 207490 Importing AVAIL programs which had IF statements embedded in command statements was causing application errors. Fixed: 12/29/00.
  • 207489 The phrase "Dual Drive" was changed to "Dual Reader" to reflect the true application of wcompens32.dll usage. Fixed: 12/08/00.
  • 207479 Application errors were encountered when the Preview Window was open and two planes were measured then intersected. Fixed: 12/05/00.
  • 207477 The slave arm was executing more slowly when running Master/Slave programs. Fixed: 12/05/00.
  • 207469 Changes in OpenGL settings were not being saved on exit from PC-DMIS. Fixed: 12/04/00.
  • 207461 Summary mode was missing the filter type toggle for basic scans. Fixed: 12/11/00.
  • 207457 If the edit window is hidden via automation, automation was disabling the edit window from being shown again even if the user chose edit window from the main menu. Fixed: 12/11/00.
  • 207456 & In operator mode, Probe Calibration would calibrate every probe for every
  • 207492 loadprobe command rather than just once for each loaded probe file. Fixed: 12/06/00.
  • 207455 Location commands were not being properly formatted in Spanish and French versions. Fixed: 12/07/00.
  • 207451 Some font and pitch sizes causing the printed report to be cropped. Fixed: 12/06/00.
  • 207446 & 207467 Settings for prints commands were being deleted when switching to Summary Mode. Fixed: 12/06/00.
  • 207445 The Report | Print command was not available when in Summary Mode. Fixed: 12/07/00.
  • 207437 Prompting the operator for the *.pdf filename to output was not functioning during every execution. Fixed: 12/06/00.
  • 207423 The Default button was being incorrectly made available on the Report | Customize | Report page when in Summary View. Fixed: 12/01/00.
  • 207422 When outputting results to an RTF file, the first dimension reported would always show in blue. Fixed: 12/01/00.
  • 207420 Data inside data field boxes was being changed when toggling between the Section Scan and Perimeter Scan windows. Fixed: 12/05/00.
  • 207412 Execution of a defined scan could crash if the scan was followed by a second defined scan where the end vectors were more than 90 degrees out of phase. Fixed: 12/01/00.
  • 207408 Execution of an iterative alignment could hang when used on a machine utilizing the B&S Backtalk interface. Fixed: 11/30/00.
  • 207403 An alignment rotation before a scan could cause erroneous data to be generated. Fixed: 12/01/00.
  • 207401 Graphical response when scrolling Hyper-reports which displayed CAD images was excessively slow. Fixed: 12/06/00.
  • 207393 Although some reduction in speed is expected, tessellation factors of less than 1 were drawing the CAD elements much slower than expected. Fixed: 12/01/00.
  • 207392 Hyper-report dimensions were being reported with incorrect colors. Fixed: 11/29/00.
  • 207384 The Report | Customize settings were not being saved when switching between the Command, Report, and Summary tabs. Fixed: 12/07/00.
  • 207379 A line constructed from two constructed points was occasionally flipping vector. Fixed: 11/22/00.
  • 207378 Some DXF/DWG files were importing incorrectly. Fixed: 11/30/00.
  • 207375 DMIS-output for the BMWMESS converter was generating incorrect features. Fixed: 11/22/00.
  • 207371 The label for True Position LMC was being incorrectly displayed as RFS in the new style report window. Fixed: 11/22/00.
  • 207367 CAD viewsets were not being properly loaded into Hyper-reports. Fixed: 12/11/00.
  • 207354 Graphical deviations were not being updated after an alignment was changed. Fixed: 11/17/00.
  • 207345 Differences in tesselation from UG to PC-DMIS could display some features disproportionately. Fixed: 12/13/00.
  • 207344 The 3D distance icon was not appearing properly in the report window box. Fixed: 12/11/00.
  • 207341 With a solid model imported - go to view setup - turn rulers on - select 2 views, enter view axes info - then check solids and Apply. If you then uncheck the 2 solids at once and apply, you would get a Dr. Watson. Fixed: 11/27/00.
  • 207340 In the preview window, the vector option was showing all zeros. Fixed: 11/16/00.
  • 207339 A sphere, which was generated in PC-DMIS, exported, then imported, would not have selectable surfaces. Fixed: 11/23/00.
  • 207337 Several dimension abbreviations were not being translated correctly into the German language. Fixed: 11/20/00.
  • 207336 The flag "SHOW COLUMN LINES" had no effect in version 3.2 so was disabled. Fixed: 11/21/00.
  • 207329 Programs created in previous versions, which had blank input features for a Best Fit alignment, were not importing correctly. Fixed: 11/16/00.
  • 207328 The uninstall program was not working correctly. Fixed: 12/11/00.
  • 207323 The ELM interface was causing the computer processor to operate at 100%. Fixed: 01/22/01.
  • 207319 Feature IDs that were hidden during learn mode would reappear when a new feature was created. Fixed: 11/13/00.
  • 207316 Certain dialog windows were commanding an excessive amount of CPU time. Fixed: 11/13/00.
  • 207312 When changing probe files inside Probe Utilities, changes to the previous probe file were not being saved even when responding "Yes" to the prompt. Fixed: 11/13/00.
  • 207309 Turning on the Show Icon in Text Boxes options in Options | Setup | General and running a program could cause computer lock-ups. Fixed: 11/10/00.
  • 207304 High points were crashing when Measure was checked on Create. Fixed: 12/06/00.
  • 207301 Dimensions calculated with the Gap option were not calculating the correct dx, dy, or dz values. Fixed: 11/08/00.
  • 207299 Creating and array variable could cause memory problems when executing the program. Fixed: 11/15/00.
  • 207297 Accessing to OPTIONS-PARAMETERS-AUTO TRIGGER caused an application error. Fixed: 11/07/00.
  • 207294 Some programs created in version 2.3 would not open in 3.2. Fixed: 11/06/00.
  • 207284 & 207274 Communications were being lost with the Faro interface. Fixed: 01/05/01.
  • 207263 & 207221 The dimension heading line was not displaying correctly in the old reporting format. Fixed: 11/03/00.
  • 207257 The right-click Move To Cursor option for DES points was removed. Fixed: 11/13/00.
  • 207250 Exporting a program to DMIS and then importing the same program would turn on the Print and DMIS Output options. Fixed: 11/14/00.
  • 207247 When importing DMIS files, the "Select Probe File to be used During DMIS Translation" dialog was not locating the correct probe file directory. Fixed: 11/21/00.
  • 207246 It was not possible to expand the THEO values for an Auto Circle with a pitch. Fixed: 12/07/00.
  • 207237 Toochanges in operator mode could result in crashes in the change cycle where the machine was forgetting the status of the mounted probe file. Fixed: 11/01/00.
  • 207230 Imported CAD files were being saved in the installation directory if the "Save" option was used instead of "Save As." Fixed: 11/01/00.
  • 207229 Auto reports were being printed even if Autoprint was set to NO. Fixed: 12/06/00.
  • 207229 Outputting an autoreport to *.pdf format was causing an application error. Fixed: 12/06/00.
  • 207218 Showing path lines was not positioning the cursor properly in the Edit Window for scan features. Fixed: 11/06/00.
  • 207204 Left-clicking to capture a surface point on a CAD image could cause an application error. Fixed: 10/26/00.
  • 207202 The XYZ trihedron was not showing with hidden lines when behind a surface. Fixed: 11/27/00.
  • 207201 Buttons in Hyper-Reports were not functioning properly. Fixed: 11/02/00.
  • 207200 Creating a UV Scan could cause an application error. Fixed: 10/26/00.
  • 207193 Posting out a program to DMIS was not functioning properly. Fixed: 10/25/00.
  • 207186 Vector point variables could not be saved without having the sheetmetal options. Fixed: 10/24/00.
  • 207184 With auto dimensioning turned on and using the TO POINTS option on any scans, an empty dimension was created for every point. Fixed: 10/25/00.
  • 207182 The displayed angle vector for an Auto Circle was not updating correctly following an edit of the vector. Fixed: 10/26/00.
  • 207175 Setting up clearance planes in the middle of a program was not applying clearance planes to previously created features. Fixed: 10/24/00.
  • 207166 IGES files with erroneous data are now checked for outlying data points which are greater than 1.0e6 in value. Fixed: 10/24/00.
  • 207164 Extra probe triggers were occurring on the Tech80 interface while using autotrigger. Fixed: 01/23/01.
  • 207157 Exporting a PC-DMIS program to DMIS, which had references to R dimensions, would cause errors. Fixed: 10/25/00.
  • 207124 Selecting surfaces was not working well with imported Unigraphics models. Fixed: 10/26/00.
  • 207110 Some older *.bas programs were not translating correctly in to Visual Basic. Fixed: 11/20/00.
  • 207081 & 207149 Opening the Leapfrog dialog was causing menu item status not to refresh when the dialog was closed. Fixed: 01/03/01.
  • 207080 Autotrigger was not working with DES points. Fixed: 11/03/00.
  • 207073 PC-DMIS was not outputting information in a correct format to be displayed properly on newer Vorne OIT's. Fixed: 11/21/00.
  • 207012 It was possible to enter invalid datum modifiers in the Edit Window. Fixed: 12/07/00.
  • 206970 It was not possible to switch statistics on and off by means of a variable. Fixed: 11/15/00.
  • 206901 The Max and Min labels from an analysis view were not being drawn in the correct locations in a Hyperview. Fixed: 10/18/00 (3.205).
  • 206803 The multiplier for Analysis Views was dependent upon the graphical dimension multiplier. Fixed: 10/26/00.
  • 206793 The "Show Column Lines" option was disabled in hyper views since they were not supported. Fixed: 11/21/00.
  • 206774 Textual analysis of location and true position dimensions was providing analysis in XYZ format when using polar coordinates. Fixed: 10/25/00.
  • 206781 The true position of a feature set now shows the number of inputs instead of zero. Fixed: 11/30/00.
  • 206694 Re-opening some programs, which used a direct Pro-Engineer file, was not redrawing all of the surfaces. Fixed: 02/21/01.
  • 206615 Leapfrog while using the scale option wasn't working properly on Faro machines. Fixed: 10/24/00.
  • 205443 High Point in box mode with a width of 0 was not working. Fixed: 12/06/00.
  • 205235 The fields for angles did not have sufficient space when displaying in Deg/Min/Sec format. Fixed: 11/28/00.
  • 203754 When opening part programs, the default dimension colors were always being used rather than those specified for the program. Fixed: 03/06/01.

 

Back to Top

[Dividing Line Image]

Version 3.2061 Enhancements and Fixes

06 April 2001
Download this list of new enhancements and bug fixes in .doc format.Download Fixes_3.206.doc

Fixes:

  • 208501 Scans could hang at the end of execution if debug logging was enabled. Fixed: 04/04/01.
  • 208491 An F9 edit of the ONERROR command was not reflecting the correct error condition in the dialog. Fixed: 04/03/01.
  • 208482 Attempting to calibrate the unsupported SP600 on a Sharpe interface machine could cause application errors. Fixed: 04/04/01.
  • 208477 PC-DMIS was deleting the stored point values during auto feature FindNoms when a curve was found close to the surfaces being used. Fixed: 03/30/01.
  • 208475 While in curve mode during Find Nominals for Point Only Mode, surfaces were still being found. Fixed: 03/30/01.
  • 208474 Programs executed while in Summary Mode were continuing to display the Summary Mode window instead of the Report Mode window. Fixed: 04/04/01.
  • 208469 Using two probe changers, which did not have interchangeable joints, was not correctly prompting for manual probe changes. Fixed: 03/29/01.
  • 208467, 8 FindNoms was not working correctly for Auto Features. Fixed: 03/29/01.
  • 208460 PC-DMIS was exiting on a loss of communications with Faro machines. Fixed: 04/03/01.
  • 208440 F9 edit of the OPTIONPROBE command was opening the incorrect dialog if a rotary table was on the portlock but not defined in PC-DMIS. Fixed: 03/27/01.
  • 208432 Angle Between dimensions were not utilizing the major axis of slots or ellipses correctly. Fixed: 03/26/01.
  • 208431 5-axis Laser scans were not always being measured at the correct coordinates. Fixed: 04/04/01.
  • 208406 Probe Utilities were causing computer resource problems when connected with a Faro machine. Fixed: 03/23/01.
  • 208404 Iterative alignments were causing slave execution problems in dual-arm programs. Fixed: 03/21/01.
  • 208402 The Execute Feature function was causing improper execution in dual-arm part programs. Fixed: 03/21/01.
  • 208399 The right-click Open function was not working for PC-DMIS part programs. Fixed: 03/21/01.
  • 208397 Nominal values were not being found for Angle dimensions. Fixed: 03/21/01.
  • 208395 An application error was generated when calibration of a probe in an on-line program finished while working in an off-line program. Fixed: 03/20/01.
  • 208391 Manual Retract commands were incorrectly sent to Metrolog manual controllers. Fixed: 03/22/01.
  • 208390 Vector compensation was being reversed on the GOM interface machines. Fixed: 03/19/01.
  • 208388 The default communications values were not correctly set in the GOM interface. Fixed: 03/19/01.
  • 208386 Exiting PC-DMIS while on-line with a GOM interface was generating application errors. Fixed: 03/20/01.
  • 208378 If both remeasure and rmeas were used on an Auto Circle or slot, the rmeas "offset" was applied twice on the 2nd measurement. Fixed: 03/19/01.
  • 208377 Editing the nominal values of negative angle dimensions was producing unnecessary error warnings. Fixed: 03/19/01.
  • 208375 ProEngineer *.asm files were not being properly imported. Fixed: 04/02/01.
  • 208352 Starting PC-DMIS via automation could cause a Leitz interface CMM to home without operator intervention. Fixed: 03/21/01.
  • 208350 Graphical representation of the probe was incorrect during UV scanning. Fixed: 03/26/01.
  • 208346 Random hits were occurring on Faro machines when selecting the Accept button. Fixed: 03/28/01.
  • 208330 Importing DMIS programs which contained illegal variables caused the import process to hang. Fixed: 03/09/01.
  • 208251 Execution problems were encountered with some imported AVAIL programs. Fixed: 03/20/01.
  • 208152 Importing a CAD file into a program not saved in the root directory which contained a mirrored CAD file was causing the mirrored CAD image to revert to its original state. Fixed: 03/20/01.

Back to Top

[Dividing Line Image]

Version 3.2062 Enhancements and Fixes

28 May 2001
Download this list of new enhancements and bug fixes in .doc format.Download Fixes_3.206.doc

Enahancements:

  • 208649 The dimension list box for Auto-Reports was modified to be a single column list box. Added: 05/02/01.

Fixes:

  • 208900 A Ctrl-E execution of a slave command while the computer was in master mode could cause the slave machine to use the master probe file current offsets. Fixed: 05/25/01.
  • 208892 Unnecessary error messages were generated when using Temperature Compensation in manual mode. Fixed: 05/23/01.
  • 208864 Changes in Mora firmware were causing machines with the Mora interface to run slower. Fixed: 05/22/01.
  • 208841 The Vector Point Find function could not correctly pierce all surfaces. Fixed: 05/22/01.
  • 208839 Master/Slave iterative alignments which used both arms could cause execution to hang. Fixed: 05/25/01.
  • 208838 Form and Location Profile dimensions were not correctly calculating the out of tolerance error. Fixed: 05/22/01.
  • 208836 Re-opening a program with an iterative alignment could cause the calculated error to be displayed incorrectly. Fixed: 05/25/01.
  • 208830 The probe head orientation was not drawn correctly during execution of a program where the XYZ CAD orientation had been changed. Fixed: 05/23/01.
  • 208829 Labels and Dimension Info boxes were not moving to the edges of the graphics area with Automatic Label Positioning enabled. Fixed: 05/23/01.
  • 208827 LMC dimension were displaying as RFS in the new style inspection reports. Fixed: 05/17/01.
  • 208826 Dimensions created from nested loops could report the same dimension ID's. Fixed: 05/18/01.
  • 208807 Converting a polar location dimension from metric to inch units was dividing polar angles by 25.4. Fixed: 05/18/01.
  • 208806 Minimizing PC-DMIS when a program was executing was not saving toolbar locations if the window was maximized after execution finished. Fixed: 05/18/01.
  • 208799 Cad files, which contained a curve that bounded 2 surfaces, could not be mirrored. Fixed: 05/16/01.
  • 208786 Tracefields that were located inside loops were not updating correctly. Fixed: 05/18/01.
  • 208784 Probe files names could not be created that were truncated versions of previously existing file names. Fixed: 05/18/01.
  • 208780 Nominal values were appeared to change when the Ignore Cad=Part option was used. Fixed: 05/11/01.
  • 208795 Selecting the Load Active Probe command was causing printer output to be generated. Fixed: 05/17/01.
  • 208742, 24 Dimensions created Hyper-reports always used the same axes as defined in the Edit Window. Fixed: 05/04/01.
  • 208741 Nested loops were not correctly outputting the feature ID's when using the new style reporting. Fixed: 05/10/01.
  • 208737 Loop identifiers were not always incrementing correctly. Fixed: 05/09/01.
  • 208727 Dimension Info boxes were not updating in Hyper-reports. Fixed: 05/11/01.
  • 208725 Some programs with CAD from previous versions were generating application errors in 3.2061. Fixed: 05/07/01.
  • 208719 The Tech80 interface was not taking hits when executing programs which contained MODE/DCC statements. Fixed: 05/02/01.
  • 208715 The set search path option for subroutines was not working correctly. Fixed: 05/08/01.
  • 208692 Vectors were not always correctly interpreted when using a Tech80 interface. Fixed: 04/27/01.
  • 208685 2D angles to the Z axis were reporting incorrectly when in the Y workplane. Fixed: 05/14/01.
  • 208684 Counters on Tech80 interfaces were incrementing negatively with some machines. Fixed: 04/27/01.
  • 208664 Graphics were refreshing too frequently during scanning. Fixed: 04/25/01.
  • 208631 The Tech80 interface experience problems reading the latched counters. Fixed: 04/25/01.
  • 208571 The Auto Features FINDNOMS flag was being reset to NOMINALS during execution. Fixed: 04/19/01.
  • 208565 The Find Nominal option was not always working correctly when using a surface thickness with Auto Features. Fixed: 04/12/01.
  • 208514 The "OK to Home Machine" message could not be disabled from Setup Warnings for all interface types. Fixed: 05/08/01.
  • 208511 The File | Open directory was changed to be the last opened directory when having already opened a file without exiting PC-DMIS. Fixed: 04/09/01.
  • 208426 DDE server errors were experienced when using the LK interface under Windows2000. Fixed: 04/27/01.
  • 208282 AVAIL programs, which had alignment rotations about a feature, were not being translated correctly. Fixed: 04/05/01.
  • xxxxxx Issues with CW43Light wrist calibration were resolved.
Back to Top

[Dividing Line Image]

Version 3.2063 Enhancements and Fixes

30 May 2001

This version was immediatly released after v3.2062 to fix a bug causing application errors.

Download the bug fix in .doc format.Download Fixes_3.206.doc

Fixes:

  • 208923 The serialization sequence of some CAD files was causing application errors. Fixed: 05/29/01

Back to Top

[Dividing Line Image]

Version 3.207b Enhancements and Fixes

22 Aug 2001

This beta version fixes a few leftovers from the latest v32 release. Download the fixes in .doc format.Download Fixes_3.206.doc

Fixes:

  • 209628 Incorrectly formatted header and footer files were producing assertion errors. Fixed: 07/20/01.
  • 209528 Importing DMIS programs with outside circular features was not inserting the Move/Circular commands in the features. Fixed: 08/06/01.
  • 209505 True Position dimensions using 2 circular datums were not rotating correctly for the correct dimension. Fixed: 08/03/01.
  • 209485 Find Nominals was finding nominal point data on CAD levels that were hidden. Fixed: 08/09/01.
  • 209465 AutoPH9 was not saving new tips added during program execution. Fixed: 07/26/01.
  • 209434 True position dimensions were not displaying correctly for the specified reference frame. Fixed: 07/27/01.
  • 209389 Print preview was attempting to print all new dimensions on the same page. Fixed: 07/20/01.
  • 209339 Leapfrog alignments using point sets were not working correctly. Fixed: 08/03/01.
  • 209331 PC-DMIS was not updating the status bar messages when scans following points in a program. Fixed: 07/16/01.
  • 209274 True Positions dimensions could cause serialization errors in some programs. Fixed: 07/10/01.
  • 209255 The measured angle information was not updating when switching from True to Complement angle types. Fixed: 07/13/01.
  • 209193 Turning off CAD file layers was not also turning off the display of the CAD object names. Fixed: 06/29/01.
  • 209180 The multi-datum format for True Position dimensions was not working correctly. Fixed: 07/27/01.
  • 209145 The file d2hlnk32.dll was being installed into the wrong location. Fixed: 06/26/01.
  • 209079 Offset line was not working correctly when used in alignments. Fixed: 06/25/01.
  • 209071 Executing programs that wrote to files from a loop could cause application errors. Fixed: 06/21/01.
  • 209060 Qualification tools were not always created with the correct units if two programs were open simultaneously. Fixed: 06/14/01.
  • 209048 The ONERROR command was not working correctly in Master/Slave mode. Fixed: 06/14/01.
  • 209038 In the CMM Interface Options | Machine as Mouse window, you were not prompted to APPLY any changes made. Fixed: 7/03/01.
  • 209030 The wrist calibration dialog was displaying incorrect default values for the B axis. Fixed: 06/14/01.
  • 209011 Recall/Viewset commands were preventing the slave arm execution window from closing at the end of execution. Fixed: 06/08/01.
  • 209002 A scan with surface points where the permanent was set to 0 would be created with permanent set to 3. Fixed: 06/06/01.
  • 208993 Hard probing was not working correctly with the Tech80 interface. Fixed: 06/06/01.
  • 208983 Box selecting to create Auto Features was creating incorrect feature approach vectors. Fixed: 06/06/01.
  • 208964 The number of polyline segments used to divide a curve was limited to 50 and this caused some calculation problems. This in now limited to 100. Fixed: 06/22/01.
  • 208959 Switching from Summary Mode to Report Mode required two button clicks to activate the Report Mode window. Fixed: 06/01/01.
  • 208954 Importing a Unigraphics file was not always displaying all of the surfaces. Fixed: 06/29/01.
  • 208933 Some IGES files contained surfaces which did not shade correctly. Fixed: 07/11/01.
  • 208849 Switching from Summary Mode to Report Mode was not loading the active inspection report. Fixed: 05/30/01.
  • 208753 After changing the Loadprobe filename in the Edit Window, if the cursor was clicked over the logo bitmap, an application error was generated. Fixed: 08/01/01.
  • 208726 Executing subroutines that contained IF or CASE statements caused application errors. Fixed: 05/31/01.
  • 208716 Error messages were not being generated if non-existent subroutines were called. Fixed: 06/08/01.
  • 208694 Subroutines executed in Master/Slave programs could cause application errors. Fixed: 07/23/01.
  • 208481 Programs which were Quit without Saving while an Autosave copy existed could not be re-opened when the part program directory was different than the install directory. Fixed: 07/23/01.

Back to Top

[Dividing Line Image]

Version 3.2063 MR3 Enhancements and Fixes

25 Jan 2002

This maintenance release (MR) fixes several true position corrections, a fix for Auto Features and a couple of interface issues. It contains all the fixes made since the initial release of version 3.2063. This release is supported by Brown and Sharpe. It supercedes all previous MRs.

Fixes:

See the relnotes.txt file after installation for a complete list of fixes.

Back to Top

 