Wilcox Associates, Inc. is proud to bring you PC-DMIS 2010. This Enterprise Metrology Solutions platform brings together new aspects of PC-DMIS for the development of a complete manufacturing process control solution.
Available in this release are variations of PC-DMIS designed to assist with every aspect of the fabrication and quality control process. The newly created packages include PC-DMIS Laser, PC-DMIS Vision, PC-DMIS NC, as well as the established PC-DMIS Pro, PC-DMIS CAD, and PC-DMIS CAD++ platforms.
Also included with this release is PC-DMIS ONE, a simplified shop-floor DCC inspection package developed in cooperation with Brown & Sharpe.
Additionally, this release provides you with the optional module of PC-DMIS Inspection Planner, an evolutionary step that provides a paper-less, completely electronic inspection process.
PC-DMIS 2010 operates under 32-bit and 64-bit Windows XP; 32-bit and 64 bit Windows Vista; and 32-bit and 64-bit Windows 7. PC-DMIS 2010 will NOT function on computers using any other operating system. Also, please note the following:
The Matrox Framegrabber used with PC-DMIS Vision does not support a 64-bit operating system.
For PC-DMIS's PDF drivers to function in any 64-bit operating system, you must be using an Administrator user account.
Pentium IV or higher processor is suggested.
2 GHz XEON or Intel processor.
2 GB of RAM (but significantly more may be required if working with large CAD models).
1 GB of free hard drive space minimum for the application.
SVGA graphics card capable of OpenGL shading. (We cannot specify the exact Graphics card because every user has varying needs). Note that Nvidia GeForce video cards are not recommended. These are defined as "gaming" cards according to Nvidia Engineering.
SVGA capable monitor.
Screen resolution of 1280 x 1024 or higher.
RTF file output requires Microsoft Word to be viewed.
Microsoft® .NET 3.5.
DVD-ROM drive.
USB Port.
Recommended Minimums:
PC-DMIS 2010 operates under 32-bit and 64-bit Windows XP; 32-bit and 64 bit Windows Vista; and 32-bit and 64-bit Windows 7. PC-DMIS 2010 will NOT function on computers using any other operating system. Also, please note the following:
The Matrox Framegrabber used with PC-DMIS Vision does not support a 64-bit operating system.
For PC-DMIS's PDF drivers to function in any 64-bit operating system, you must be using an Administrator user account.
2 GHz or higher Duo-Core processor for improved performance.
4 GB of RAM or higher. More RAM may be required if working with large CAD models. You should have RAM equal to 8 times the size of your largest CAD file. (For example, if you use an IGES model of 250 MB, then 2 GB RAM is recommended)
2 GB of free hard drive space plus enough for allocated Virtual Memory equal to 8 times the largest CAD file used.
SVGA graphics card that supports OpenGL shading and that has WHQL (Microsoft Windows Hardware Quality Labs) certified drivers. (WHQL drivers can be downloaded automatically when using the Windows Update software.) On board video card memory should be based on the size of your largest CAD file.
For use without CAD models, 64 MB video memory.
For small to medium CAD files (50-100 MB), 128 MB video memory.
For large CAD files (>100 MB), 256+ MB video memory.
RTF file output requires Microsoft Word to be viewed.
Microsoft® .NET 3.5.
SVGA capable monitor.
Screen resolution of 1280 x 1024 or higher.
DVD-ROM drive.
2 USB Ports.
Depending on your specific needs, the recommended system specifications for this version of PC-DMIS may be much higher. A more substantial computer system may be required to accommodate part programs using Automation or complex Reporting objects. Be sure to consult with your PC-DMIS distributor to find out the type of computer system you will need in order to run this software at its optimum capability.
When using 3rd-party drivers you should contact your local Hexagon representative to ensure Operating Sytem compatibility.
PC-DMIS 2010 also continues to support Enterprise Metrology Solutions that expand upon the already full-featured functionality of PC-DMIS Pro, CAD, and CAD++. Listed below are additional packages available since PC-DMIS 3.7.
Established since version 3.5, this variation of PC-DMIS provides a simplified user interface designed for basic inspection but contains many available options for somewhat complex measuring needs.
Established since version 3.5, this variation of PC-DMIS is designed for working with imported CAD models to increase the ease of creating inspection programs as well as analyzing complex geometries.
Established since version 3.5, this variation is the most comprehensive version of PC-DMIS, containing the functionality of PC-DMIS CAD and Pro, along with Gear and Blade measuring package options.
PC-DMIS can be used in combination with supported laser probes to measure features on a part or to collect data. Laser probes allow you to easily and rapidly collect millions of points of data (called clouds of points). These clouds of points are then used within PC-DMIS for surface contour maps, export to reverse engineering packages, and creation of constructed features.
A true measuring package available for use on a computer controlled machining center for initial layout and setup inspections, first piece inspection, and even final inspection of machined parts.
A cornerstone of the Enterprise Metrology Solutions suite, the PC-DMIS Inspection planner is an evolutionary step towards bottom line time savings for inspection.
PC-DMIS Inspection planner is integrated directly within the CAD system to allow the CAD engineer to create a definition of features to inspect, datums to use, and the proper GD&T to apply. This electronic inspection plan can then be used throughout the entire inspection process making it a truly paperless task.
Clip laser data horizontally and vertically (Laser)
CAD Groups
Image Capture (Vision)
Total Station Support (Portable)
Fast Probe Mode
Y14.5 2009 GD&T Support:
- Bidirectional Positional Tolerancing
- Unequal Tolerance Zones
- Square Area Symbol
ScanShark V4i and V5 Scanner Support on Romer (Cimcore) Infinite Series Arms
These and other prominent enhancements, categorized by functionality, are discussed below.
Graphics and Graphics Display Window
Save Specific CAD Transformations - Using an improved CAD Assembly dialog box a new Replace Component right-click shortcut menu option in the tree view for the assembly allows you to import a new model on a selected node, replacing whatever model was existing on that node. The newly imported model will retain whatever transformation was in the old node.
Limited CAD Selection for Generic Features - With the Construct Generic Feature dialog box open you can now select wireframe line or point features.
Path and Path Lines
Moving in Only 1 or 2 Axes - You can now lock one or more axes of a MOVE/POINT command in the Edit window's Command mode by deleting that axis value. Motion in those axes are then ignored.
Clear Point Move - A new Clear Point tab in the Parameter Settings dialog box lets you define a safe point to which the arm as well as the form of the move.
User Interface
Many Toolbar Icons Updated - Many of the toolbar icons have been updated to provide consistency and additional clarity of purpose.
Help Button for PC-DMIS Settings Editor - A help button now makes it more clear that the PC-DMIS Settings Editor contains its own help file documentation. In addition, the user interface was slightly modified removing the Cancel and OK buttons replacing them with a single Close button which will then display a save/discard dialog box for any changes that weren't already saved when you clicked Close.
Additions to Probe Settings Dialog Box - Two new boxes have been added to the Probe Settings dialog box that were previously only available via the PC-DMIS Settings Editor:
Clearance distance along the tip shank vector during qualification
Minimum number of calibrated tip orientations for size averaging boxes.
Additions to Edit Probe Data Dialog Box - The Edit Probe Data dialog box has been expanded to accommodate changes for both the Tip Size averaging enhancement and the Fast Probe Mode enhancement.
Additions to the Measure Probe Dialog Box - The Measure Probe dialog box has been sized and reorganized to allow for the addition of the new Reset tips to Theo at start of calibration check box and the new Tips to Use if None Explicitly Selected area.
New "Reset Tips" Button - This new button, added to the Probe Utilities dialog box, lets you reset selected tips to their theoretical (non-calibrated) state.
Export an Import
XML Export - A new XML Export menu item allows you to export your part program in XML format.
Laser
Clip laser Data Both Horizontally and Vertically - Some Auto Features now support the ability to not only clip feature data in the horizontal direction but also vertically as well.
Vision
Magnification and Illumination Buttons on Live View - The Live View tab now contains buttons directly on that tab to control magnification and illumination.
Hardware Support and Hardware Settings
Total Station - You can now use Total Station laser devices with PC-DMIS Portable.
Total Station: Move To / Point To - Total Station devices have the ability to not only move to a feature but they can point the laser beam to specific areas on the part to identify out-of-tolerance dimension information.
Total Station: Toward / Away Compensation - Total Station devices support the ability to choose a normal vector on 3D circle of slot features that compensates toward or away from the device.
Fast Probe Mode - A new fast probe mode command can be inserted into the part program. This speeds up how analog probes on certain machines take individual hits.
PEM Extension Support - You can now define a clearance distance to support using empty PEM extensions inside a probe changer.
Dimensioning
Bidirectional Positional Tolerancing - True Position FCF dimensions now support the bidirectional positional tolerancing in the form of Radial Arc or Right Angle to Radial Planar Tolerance axes. See Bidirectional Positional Tolerancing - True Position FCF dimensions now support the bidirectional positional tolerancing in the form of Radial Arc or Right Angle to Radial Planar Tolerance axes.
Unequal Tolerance Zones - Profile FCF dimensions now allow you to define unequal plus or minus tolerances and use the Unequal Tolerance Zones symbol. See the Unequal Tolerance Zones - Profile FCF dimensions now allow you to define unequal plus or minus tolerances and use the Unequal Tolerance Zones symbol.
Square Area Symbol - Flatness FCF dimensions now support the square area symbol for per unit flatness defined in the ASME Y14.5 2009 standard. See the Square Area Symbol - Flatness FCF dimensions now support the square area symbol for per unit flatness defined in the ASME Y14.5 2009 standard.
Customized Datum Reference Frames - Supporting the ASME Y14.5 2009 standard, you
can now create customized datum reference frames.
Reporting
Disable/Enable UTF-8 Encoding for DMIS Ouput Files - When printing to a DMIS file, a new check box lets you enable or diable UTF-8 encoding on the exported file.
Two New Automation Methods: AddControl and ItemControl - These automation methods in the ReportConrols object return a new object type that allows you to reference additional properties previously unavailable.
Comments now allow image and movie media files - Full-screen comments now support the display of image and movie files.
Report Alignment Toolbar - A new toolbar can assist you in organizing and aligning objects in the Report window.
Constructed Features
2D / 3D Features - Circle, Ellipse, and Slot constructed features now support constructing those feature as either 2D or 3D features.
Languages
Help Files Localized - The following now have the 2009 Core help file translated into their language:
Traditional Chinese
Simplified Chinese
Italian
German
French
Czech
Portuguese
Swedish
For a complete list of enhancements, view the readme.txt file for this version.
106103 - EN # 505877. Implement a feature extraction library able to work with all the non contact sensors supported by the company. Step 1: Integration of the Cognitens libraries.
106391 - Need ability to turn specific HASP option on/off through executable
106392 - HASP SRM 1 - Create base HTML templates set up login form so that people can log in and out
106393 - HASP SRM 2 Create way for users to update their account info (name email telephone location etc.)
106456 - Update ExtCmmData
106480 - PC-DMIS Icon Cleanup
106522 - ER# 505963 : TESA - Add support for new Visio Jogbox on the VISIO 300GL
106583 - Add 45 degree CNC probe model for Red Bull
106584 - Create Sheffield Apollo RS-220 machine model
106607 - DMIS: Bump m_dmis_version to 5.2
106680 - Add Generic XML Output/Input Function to PC-DMIS
106681 - Add XML .NET support into PC-DMIS
106685 - Make the logger diagnostics files to stay under the same folder
106704 - Add new dual arm machines to packing list
106706 - Need to be able to select Vision for the Basic and Premium configuration
106707 - Integration in PC-DMIS of the CMS toolkit V.2.1 for Ver.3 sensors. Step 1: create a patch in PC-DMIS for installing the previous CMS toolkit v.2.0 for compatibility with the pevious CMS sensors Ver. 1 and 2.
106721 - On CAD import support merge
106747 - Move schema def into implementation so schema bump doesn't require rebuilding so much
106793 - Fix packing list for changes that were transplanted where the associated fiels were not through QA
234275 - Offline: "move commanded outside travel limits" on the initial moves of the pp.
242145 - 2D angle dimensions to features between a line and a plane result is coming out different.
248442 - Why is the DIST2D calculation only reporting the distance in one axis?
255588 - Sometimes the machine will stop after the first DCC hit measurement and the operator has to press DONE twice on the jogbox to continue in DCC.
257115 - step import not working on a fresh program in 4.3
257553 - CRASH : delete dimensions pc-dmis crash
258464 - CAD imported with Step is unusable
261161 - SYSTEMS 4 UI : true position in between get incorrect result in Chinese resource
262773 - The comment command above feature MLBHV1245_UZAA is added twice whenever I run the optimize path operation
262970 - SYSTEMS 4 CONFIG : PC-DMIS Basic & Premium expose CAD functionality if the part program was created in a higher product level....
263010 - Drop down list next to Set as Default icon in Reporting Toolbar does not function
263098 - Unable to select Auto Features on CAD model (imported as JT model)
263122 - Stupid merges needed for Mercurial
263440 - Feature Calculation Error the first time I've tested this circle
263669 - Point Info shows the values from the previous execution
263797 - The Close button in the CAD-History dialog is not anchored.
263896 - Load an IGS-File
264026 - Please review the default Increment2 values for Patch scan for the various CMS modes
264027 - Row Overlap does nothing on scans
264053 - Summary Mode and Edit Window are out of sync
264162 - FTA display is not working properly after PART/Machine relation is defined
264210 - 3D distance is initially wrong
264285 - ColorMapSwaps Surfaces
264442 - COPOPER IMPORT xyz file only imports file in metric units
264478 - LongLine filter: can't use the arrows controls are misplaced
264479 - Weighted Average filter: values misplaced in the controls
264530 - Ringband showing up for EdgePoint in Summary Mode
264547 - True postion header no longer word wraps it did just fine from 4.0 to 4.3 why was it stoped
264549 - The FCF Line profile of a prismatic (Circle) feature is defaulting to VECTOR fit.
264564 - Feature naming is wrong if you use Remove Last Feature
264601 - A probe 'reflectorless' is not created
264665 - Starting with cursor at ending of the program Portable Laser Execution isn't working right.
264672 - Scan label displayed in the wrong place on the CAD model
264679 - On TesaVisio 200 Zoom manual illumination is not refresh properly : changing illumination with step less than 0.5% is not sent to the machine controller.
264684 - /interface:TPS switch did not configure installation correctly
264688 - Legacy True Position dialog has some border overlap issues in English...
264689 - Part of the Location Advanced dialog is bleeding over into the Basic dialog...
264695 - Inconsistent confusing and unstructured command syntax for COMMENTS.
264700 - The GeoCOM error numbers need to be be presented as error strings
264757 - Plan dialog: the Cancel button doesn't correctly work.
264780 - OLH documentation can't pull out both English and Chinese
264785 - Calibration Math Error on A45 angles very high errors ( 2mm ) on A30 angles
106552 - Allow a Move command that moves in 1 or 2 axes only (instead of all three)
106545 - NIST App Enhancements
106544 - Do MultiGage style 24x24 icons for the Measured features Reflex Page
106543 - Do MultiGage style 24x24 icons for the Constructed features Reflex Page
106542 - Do MultiGage style 24x24 icons for the first Vision Live View Toolbar
106524 - Add alignment controls to the constructed features on the Vision Gauge window
106515 - Add hole pattern to the Sheffield Apollo RS-50 table model
106514 - Implement a feature extraction library able to work with all the non contact sensors supported by the company. Add cloud needs to pass the feature type.
106509 - Add the ability to enter move points in polar coordinates
106507 - UV and grid scan types only show 2 decimals for xyz in path definition page.
106499 - Add a "Help" button to the Settings Editor to make it obvious that there's OLH available...
106495 - Handle warnings as warnings and not errors
106488 - Add constructed features to the Reflex Vision Gauge window
106482 - Integrate of the new CMS Ver. 3 Cad model and geometry into PC-DMIS
106470 - Add feature set handling to task #106251
106457 - Make doc & MOD schema doubles
106450 - WaitOptimization for tool changer on special option
106442 - Change all instances of power lock to the Leica branded version - PowerLock
106429 - Add a 3D construction to hole type features
106383 - Reporting ZEISS controller error messages to PCDMIS
106348 - Fix [Config] option output into the debug file
106235 - Add the ability to save transforms to be used for later transform operations
106086 - Develop 'probes' to represent different measurement modes of the Total Station
105935 - Add Zeiss Carat machine to the build
105876 - Add Reconnect / Disconnect automation items to support Leitz machine firmware.
265031 - Cannot create freeform scans on most CAD surfaces
264955 - Zeiss new interface doesn't compile under VC 6
264906 - ManualCMM - wrong read-outs after alignment
264863 - Summary Mode doesn't work for the Toolkit
264827 - Can't measure or extract a Round Slot using a negative Overscan: I always get "Invalid Data"
264791 - "Feature Calculation Error" when executing program on some features but test works fine on same features
264740 - Need ability to add move points to FreeformPlane
264735 - When I do a Qual Check on a SP25 The value of PRBDRV changes.
264693 - AutoCylinder Stud probing path has changed from version 4.1 to 2009 MR1...
264690 - AutoCreate dimensions flag is not staying set...
264661 - Push Probe Version resource changes related to file format conversion
264587 - Volcomp file load leaks a stream handle on exit
264573 - Can't construct a plane using outlier removal and Gauss filter: it crashes
264567 - Reflex Vision - Icon needed not button
264531 - EdgePoint crashes
264476 - Rotary Scan
264472 - I can type negative values for Spacer and Indent in the AF dialog, even if they're invalid
264458 - Opening a program twice causes an application error.
264448 - When selecting cad to create AF's the pathlines are being re-drawn multiple times.
264441 - PDF output not working in Vista x64...or Windows 7
264440 - Some tooltips are wrong.
264436 - Sensor not initialized after probe change from CMS30 to CMS
264312 - ANSI_Y14_5_Dimens_AngleCoaxSymm automated test is reporting a failure
264284 - Get Toggle type working
264283 - Get IDimension working
264282 - RMEAS "default" is broken. Causes a crash.
264245 - Serializing back to previous versions, and then reopening with PC-DMIS 2009, the versions from V3.2 to V3.7 are crashing PC-DMIS 2009.
264240 - PowerUser installation/usage issues at Stadler rail
264224 - Pressing F1 on REPORT/TEMPLATE or its menu item goes to intro help topic
264204 - Siemens NC Read Cnc Var sometimes hangs
264165 - Auto Round Slot measurements with sheetmetal probe are not solving correctly
264154 - "Working with Contact Find Hole Properties" doesn't not exist in 2009 English OLH
264132 - When opening a V4.2 (or V4.3) part program w/ CAD and COPS takes nearly 3 minutes on the same laptop the program used to take a few seconds.
263991 - If they set the reference to a CAD file that has been created previously during a mirror operation, then the original not mirrored CAD file opens.
263984 - Snap = YES will not stay when using Point Only Mode and Find Noms
263983 - PC-DMIS is crashing when mirroring a part program
263981 - Stop prog execution using automation
263925 - When using the iterationalignment wizard, at the 3rd step , the features in the feature list always miss one .
263917 - PC-DMIS crashes, application error, when selecting TEXTANDCAD template in report window
263902 - Can wipe out custom reports without knowing it
263884 - MazakIntegrex creates header line in EIA files that is unreadable by Matrix controls
263770 - When using TEST button with Autofeature Edge Point, you don't see the final points in green like other laser autofeatures.
263706 - Help file for Laser: No explanation of the Auto Clipping function
263693 - Point Info returns a wrong value
263692 - Select Point Info Dialog did not show the FCF
263609 - Best Fit Alignments not updating when using 2D Profile
263474 - The wrist of Arm1 unawares rotates of an angle of the wrist of Arm2
263441 - Crash trying to expand commands in the EW while the AF dialog is open after a feature has been tested
263321 - Can't use Mark Used from probe utilities/Measure dialog whe modifying saved parameter set.
263230 - Path lines of Auto Feature are not correct
263127 - If Abort is pressed in Metrosoft, the server often hangs up.
262579 - Update Nominal feature option should not update feature nominal in some cases
262509 - CAD window can't display this part model stably
261642 - Cannot output Flatness of any constructed set of (2) Measured Planes...
261408 - Absolute speeds between multiple arms
261407 - Scan Speed not sent to ARM2
261406 - Point density not sent to ARM 2
261176 - Value instead of Variables showing in AutoFeature Start/End Angle fields when opening a prior version (e.g. V4.1) PC-DMIS program that uses them - PROGRAM MIGRATION ISSUE
258860 - In French language Help is old 42 version and it is not linked with the active window
258352 - Patch Scan with WLS, last scan always goes to D point
257908 - Problem handling comm port related communications for ACR1 and probably Tesastar-R when used on slave arm of dual arm system
257828 - Incorrect Probe Animation with rotary tables
257257 - The message asking "OK to empty this pointcloud?" should include the Cop object ID
PC-DMIS 2010 MR1 contains these main enhancements:
Additional CMS Laser Support (MR1) - CMS Lasers are now supported for dual arm systems.
Machine Assembly (MR1) - A new Machine Assembly dialog box lets you control the visibility, transparency, and color of the CAD components comprising a displayed machine.
Command Line Additions (MR1) - New command line switches allow you to load CAD models for part programs created by command line.
Probe Calibration Warnings (MR1) - For Vision probes, Calibration warnings are now displayed in a new area on the Probe Calibration dialog box.
Illumination Off for Contact Probes (MR1) - For Vision, a new registry entry controls whether lamps are turned on or off when switching to a contact probe.
Additional Analysis Object Properties (MR1) - For Reporting, new MaxMinSize, MaxColor, and MinColor properties let you customize colors and sizes for max/min deviations.
The complete list of updates and fixes are listed here:
-------------------- Minor Release 1 Updates (June 01, 2010) --------------
106104 - Change the QuickFixturing dialog to read R&R Fixtuing as opposed to the current Rayco.
106145 - Implement execution for the new move to / point to command.
106146 - Create edit window templates for both command and summary modes.
106192 - Support of new cards (from Tech80) combining two cards for simultaneous work.
106336 - Develop method for taking points at the totalstation using its keyboard or the red button on the side of the device.
106461 - New customized Datum Reference Frames FCF Location Tolerances (True Position, Profile with datum, Symmetry, Coaxiality, Concentricity, and Runout).
106466 - Add BOUNDARY modifier on true position (for slots) (also 1994 standard).
107037 - Reflex Vision: Link F9 to Vision Gage Window.
107047 - Extended Edge Point - Add ClassDiagrams to the BaseClasses and the ContourPoints.
107048 - Extended Edge Point - Make decimal digits for the dimensions of the TK features depended on the part program settings .
107053 - Reflex Vision: Remove Irrelevant information from the Summary Mode.
107064 - Possibility to execute feature extraction into a part program in synchronous mode.
107072 - Add a status bar for the Faro tracker.
107073 - Revisit the menu structure for Faro, and enable items that are are supported by current Faro API.
107074 - Add support to the interface for common Tracker features.
107098 - Reflex Vision: Add True Position dimension to the Vision Gauge Window
107100 - Auto LIV freeze should default off
107101 - Reflex Vision: Add code to resize the contents of the Vision Gage window when the frame resizes.
107115 - Allow the point info dialog to only show dimensions assigned to the AWO (enhancement 506147).
107117 - Allow the possibility to turn off leader lines with a parameter (enhancment 505679).
107132 - Add information for upgrading SW DCI code to use newer functions.
107140 - Complete all 3 variants of show_error() global function to receive the object which generated the error. Then AF lasers on error to provide 'this' to show_error().
107141 - Add Debugging info to the UJB Bridge App.
107148 - Reflex Vision: Disable automation in Reflex Vision.
107149 - Vision Basic: Disable RGB mixing.
107150 - Vision Basic: We need to disable gauge tragets and comparator targets.
107152 - Add IDS framegrabber support for v4.6 to support Windows 7.
107153 - Improve IDS framegrabber image quality.
107155 - Add resourcenum options for Vision Basic and Reflex Vision.
107159 - Add new probe to probe.dat for CMM-Ve.
107161 - Increase max laser gain from 63 to 100.
107164 - Vision Basic: Disable MultiCapture from Vision Basic.
107165 - Vision Basic: Removed complex auto features from the Vision Basic product.
107167 - Reflex Vision: Remove toolbars from Reflex Vision.
107169 - Vision Basic: Disable all constructed features except Line, Plane, Point, and Circle.
107170 - Vision Basic: Remove specified options from Vision Basic.
107171 - Reflex Vision: Remove PC-DMIS from the product name.
107178 - Create new Reflex Vision interface using WPF.
107203 - Modify CADObjectsDropBoundaryAll() to handle multiple boundary curves.
107207 - Vision Basic: Add Skip button to QS for level on aligment.
107211 - Move Vision machine specific menus into a Vision main menu.
107212 - Combine animation controls into one dialog.
107213 - Provide ability to hide/show or change transparency of CMM machine parts.
107223 - Add draw file for new CMM-Ve probes.
107226 - Need the ability to use a point cloud operator as the input to a surface profile dimension.
107232 - Settings Editor should set UAC to require admin rights.
107243 - Add MaxMinSize, MaxColor, and MinColor properties to AWO. These will be used to draw a point of the appropriate color in the AWO for the MAX and MIN point.
107289 - Expand AWO to allow labels for multiple commands at the same time.
107313 - VW-Benchmark - "Move Path Line" dialog should display in current part coordinates.
107319 - Reflex Vision: Selecting a dimension on the gauge window should select graphics/CAD view tab.
107321 - VW-Benchmark - Make sure that the FA for constructed round slots isn't missing in the DMO file.
107335 - Reflex Vision: We need to measure the distance in Z without changing workplane.
107348 - Change the default Snap to Edge distance in Vision to 20.
107349 - Add setting to switch the lamps off when switching to touch probe.
107356 - Add UseParameterSet and FreeformPlane to install.
107367 - Add support for R20.
107384 - LeaderLine property on hyper object.
107387 - Vision Basic: Remove the alignments from QS which are no longer required.
107393 - Poratable (manual) scan should recover the last 27 stripes like DCC scan does.
107425 - Circular Moves.
107426 - Update to use Metronics SDK V2.22.
107432 - Correct version information for MORA and IPLUSPLUS interfaces.
107385 - Update Header file for Geocom.dll to address accuracy issue....
107064 - Possibility to execute feature extraction into a part program in synchronous mode.
107140 - Complete all 3 variants of show_error() global function to receive the object which generated the error. Then AF lasers on error to provide 'this' to show_error().
107393 - Poratable (manual) scan should recover the last 27 stripes like DCC scan does.
107487 - Update PROTO Installer to 1.6.2. for Johansson machines....
107202 - Add a toolkit method that returns a boundary point for each boundary edge curve.
106671 - Extended Edge Point - Add to IToolkitCommand interface methods to know if it is a Legacy Extended Legacy or Extended command and to get/set data for Legacy and Extended Legacy commands.
252742 - The custom report dialog does not resize properly.
254333 - A DMIS Engine pp is only running if there's a 14.T1 or 13.T1 probe command inside.
255631 - Strange characters in the filter: "Files of Type".
255838 - The File | Save As dialog has a subtle change to size of the version combo box.
256189 - Interface to Mora Pico.
256244 - A dotted Leaderline in Customreport is printed in pdf to a drawn through line.
256486 - Pixel size verification failure.
256608 - Untranslated text in Autofeature Caption Right-Click menu.
256815 - 3D Rotation Window isn`t visible in Custom report.
257586 - The probe of Arm2 is not visible in the Active List of Probe Utilities.
258475 - TAGs do not mirror correctly in the case of Vertical option.
258476 - You will found in German for Line autofeature "GERADE" and in summary mode "LINIE".
258589 - Graphic View Toolbar: X+ icon has the front surface shaded.
258591 - COP and COP Toolbar options showing up when not enabled in portlock only under specific conditions.
258797 - Calibration is done ignoring the angular adapters rotations.
259007 - Toggle Graphics View Transparency is not implemented.
259586 - PC-DMIS Sound events are not localized correctly.
259604 - Replace hard-coded strings with resource strings
259712 - Arm1 probe disappears when I delete the arm1 machine.
259819 - Calibrating a group of tips in case one of them fails I can't do anything else than a Cancel in the execution dialog: Skip and Continue does nothing.
260294 - Freeform scan seems to choose the right tips but inserts a wrong one without prompting.
260367 - Changing Color of Leaderlines by manual input of colornumber is not working.
260368 - Changing color of leaderlines in property of cro hasn't effect on the arrowhead of distance dimensions.
260690 - The level combobox in the CAD assembly dialog does not show more than 13 characters of the level name.
260982 - Switching UI between "Use large menus" and "Use small menus" check boxes doesn't automatically restart PC-DMIS.
261434 - Settings editor icon is lower resolution than other icons.
262259 - Annoying message when typing in probe name if typed too slowly.
262365 - Execution dialog remains open after a Continue.
262446 - PCDMIS is thwarting my attempts to do things like a LoadProbe/Tip/Startup Alignment whenever I start a new program.
262747 - Setup dialog regarding installing Frame Grabber software appears to be hard-coded.
262775 - TESA: VISIO-GL : Update probe definitions for VISIO300-GL to support Sentech camera and new zoom combinations.
262975 - The title of Auto Feature Dialog is changed after clicking Create Button.
262978 - Extreme slowness creating a Freeform scan.
263192 - Strange results when using xact TP.
263209 - Opening the Live View on Arm2 is too slow.
263337 - Changing Sensor Frequency Exposure is cut to 500 if AutoExposure has learned a higher value.
263390 - Bottom light appears to have Illumination Overlay during calibration.
263415 - I am able to access and run cross probe calibration with an uncalibrated probe.
263672 - Variables PART_NAME, REVISION_NUMBER, and SERIAL_NUMBER are not working in Custom Report Grid Objects.
263845 - Next hit after parameter change fails.
264029 - Crash editing an re-executing a scan.
264036 - Text on checkbox 'Nur auf aktuelle Seite' in the Label Layout Wizard dialog is truncated.
264147 - Error importing IP file from eTool.
264158 - Auto Notch Slot ID was not named correctly.
264326 - AutoClip is not applied in the LiveView.
264340 - The text on label 'Anz. der Messpunkte:' in the 'Taster Kalibrieren' dialog is truncated.
264348 - The text on button 'Farbe bearbeiten' in the German 'Merkmalsfarbe bearbeiten' dialog is truncated.
264349 - The text on button 'Farbe anwenden' in the German 'Merkmalsfarbe bearbeiten' dialog is truncated.
264362 - The text on radio button 'Durchsto?en entlang eines Strahls' in the German 'CAD ûÁerprûÅen' dialog is truncated.
264368 - The text on label 'Abstand' in the German 'Auto Element' dialog is truncated.
264369 - The text on label AnfangsstûÓzpunkte' in the German 'Auto Element' dialog is truncated.
264374 - The text on label 'Relative Messung' in the German 'Auto Element - Plane' dialog is truncated.
264379 - The text on radio button 'Nennwerte Berechnen' in the German 'Geradenvers?tze' dialog is hidden by the radio button 'Vers?tze Berechnen'.
264385 - The text on checkbox 'Toleranz verwenden' in the German 'Abh?ngige Kurve' dialog is truncated.
264386 - The text on label 'Berechnungstoleranz' in the German 'Abh?ngige Kurve' dialog is truncated.
264387 - The text on label 'Faktor der AusdûÍnung' in the German 'Abh?ngige Kurve' dialog is truncated.
264390 - The text on radio button 'Innen' in the German 'Abh?ngiger Zylinder' dialog is truncated.
264391 - The text on radio button 'Au?en' in the German 'Abh?ngiger Zylinder' dialog is truncated.
264392 - The text on label 'Durchmesser' in the German 'Abh?ngiger Zylinder' dialog is truncated.
264394 - The text on radio button 'BE Neukompensiert' in the German 'Abh?ngiger Zylinder' dialog is truncated.
264395 - The text on radio button 'BE Neukompensiert' in the German 'Abh?ngiger Kegel' dialog is truncated.
264397 - The text on radio button 'Innen' in the German 'Abh?ngiger Kegel' dialog is truncated.
264398 - The text on radio button 'Au?en' in the German 'Abh?ngiger Kegel' dialog is truncated.
264399 - The text on Label 'Duchmesser 1' in the German 'Abh?ngiger Kegel' dialog is truncated.
264400 - The text on Label 'Duchmesser 2' in the German 'Abh?ngiger Kegel' dialog is truncated.
264402 - The text on radio button 'BE Neukompensiert' in the German 'Abh?ngiger Kugel' dialog is truncated.
264403 - The text on radio button 'Innen' in the German 'Abh?ngiger Kugel' dialog is truncated.
264404 - The text on radio button 'Au?en' in the German 'Abh?ngiger Kugel' dialog is truncated.
264409 - The text on radio button 'Gruppe ausblenden' in the German 'Gruppe' dialog is truncated.
264410 - The text on label 'Gruppen-ID ' in the German 'Gruppe' dialog is truncated.
264411 - The text on ckeckbox 'Nur auf aktuelle Seite anw.' in the German 'Etikett-Layout-Assistent' dialog is truncated.
264412 - The text on label 'Kugelfarbe' in the German 'Etikett-Layout-Assistent' dialog is truncated.
264414 - The text on checkbox 'Elementschwerpunkt verwenden' in the German 'Etikett-Layout-Assistent' dialog is truncated.
264417 - The text on menu item 'Druckereinrichtung Protokolfenster' in the German 'Drucken' menu strip is misspelled.
264418 - The text on checkbox 'Elemente einblenden' in the German 'Protokoll' dialog is truncated.
264419 - The text on checkbox 'Kommentare einblenden' in the German 'Protokoll' dialog is truncated.
264423 - The text on radio button 'Nur Merkmale innerhalb der Toleranz einblenden' in the German 'Protokoll' dialog is truncated.
264424 - The text on button 'Gewichtung bearbeiten' in the German 'Besteinpassungs-Ausrichtung' dialog is truncated.
264425 - The text on button 'Gewichtung erstellen' in the German 'Besteinpassungs-Ausrichtung' dialog is truncated.
264426 - The text on checkbox 'Entlang X verschieben' in the German 'Besteinpassungs-Ausrichtung' dialog is truncated.
264427 - The text on checkbox 'Entlang Y verschieben' in the German 'Besteinpassungs-Ausrichtung' dialog is truncated.
264428 - The text on checkbox 'Entlang Z verschieben' in the German 'Besteinpassungs-Ausrichtung' dialog is truncated.
264429 - The text on label 'Name des benutzerdefinierten Protokolls' in the German 'Benutzerdefinierte Protokolle fûÑ' dialog is truncated.
264484 - The Legacy concentricity dimension looks reasonable while the FCF Concentricity dimension sis over 200mm in error.
264491 - When I enable the Shortest checkbox option in the 3d distance dimension the result is unreasonably short.
264508 - Siemens Lathe Macros do not read the tool offset on Hembrug machine.
264513 - The square slot FCF bonus values are suspicously small (0) in v2009MR1 compared to v432.
264541 - Auto feature Vector Arrow too LONG and TOO BIG AROUND.
264580 - It takes two attempts to change the nominal size for the Angulairty of a cylinder.
264622 - When I try to switch CNC machines I get an application error.
264781 - Basic scan axis can't work correctly with the analog probe.
264821 - PCD2Excel Wizard handles FCF's but calculations appear not values.
264985 - Tracking Speed is not sent to the SMP400 Controller for BasicScan Linear (Closed-Loop).
265081 - Straight-line Moves During Calibration Cause Probe-tip Collisions into Cal Sphere.
265101 - Togling off graphic display in command arrows remain visible on the screen.
265118 - online scanning data can't update into profile command.
265163 - Y Mirror of dmis program fails after same technique worked well in v4.1 fails in v2009 as well.
265204 - No error message if a probe is called which is not defined in the TC.
265266 - PartProgram.OnExecuteDialogStatusMsg event never called.
265281 - Scan "Closed Line" is displayed wrong during OFFLINE programming.
265352 - linear open scan calculated thw strange increment value when I change the line to variable method.
265406 - ET value on Probe Readout Window is no longer displayed in Execute Mode.
265441 - iplusplus.dll Interface did not fit with the installation files.
265486 - Missing surfaces when the PP is opened in PC-DMIS v2009 MR1.
265544 - In the German 'Auto Elemente' dialog the inner/outer toggle is translated 'Ein/Aus' which means 'On/Off'.
265647 - When migrating a program with saved and recalled Views from V4.2 MR1 to V2009 MR1 Feature Labels turn on in the graphics window that were not displayed in the Saved Views in the earlier version.
265657 - Point measurement with change of probe index.
265662 - Head Feed Rates do not have decimal point on Fanuc post.
265671 - New Icons in the toolbars are not displayed.
265707 - Analysis Window Arrow density 0%.
265711 - Changes the password to upper case characters when saving.
265828 - Arrow Density to set from Program V3.7MR3 to V2009MR1.
265927 - Error Creating Analysis View.
265957 - Convert all CylinderConcentricCircleScans to defined.
265980 - Editing 2-Point measured Round/Square slots causes number of points to be over written.
266053 - VHSS scanning doesn't work on B4 controller.
266068 - IGES file able to load (alternate) in V4.3mr1 not in 2009.
266138 - XML Import/Export is not tied to the XML proglock setting.
266182 - Circular run out dimension difference from FCF to legacy.
266215 - Report shows the profile as good but the tag and the indicator bar on the graphic analysis as well as the deviation arrows indicate the profile is out.
266217 - Reporting template not displaying labels - reporting only contains cad reporting object and leader lines.
266233 - Probe read out window will dock to the tool bars if you move it up in that area and will also strech it out.
266236 - EDM Preset and Measure.
266254 - Adding move/clearplane between hit/basic of autocircle causes a different actual diameter result.
266295 - Hit value off by 1.
266296 - Memory leak.
266298 - Alignment Toolbar option. Audi wants it to be auto enabled.
266347 - Problem with positve and negative angles in programs from older version.
266357 - Full path on User Selected Template.
266374 - PC-DMIS does not keep the viewset name used to generate an automatic HR.
266376 - Registering dlls/ocxs.
266401 - Problem with AutoFeature vector point and Catia DCT.
266416 - Section Scan: Execution mode: RELEARN / Nominal: Nominals and Find Nominals / Use BF active. If deaviation is negative scan is not generated propperly. Which are the right settings?
266427 - Drawn arrow with GRAPH=ON does not point in right direction.
266448 - Toolkit cannot deserialize when PC-DMIS is started from VB.
266479 - Probe Change corrupts probe file.
266502 - Problem with the Angle Dimension from PCDMIS V42MR2 to PCDMIS 2009MR1.
266628 - we should use HasTransparentBackground() in some places instead of IsTransparent().
266640 - RT Commands not sent (Raytheon test with Zeiss I++ server).
266660 - Can't change Worst value.
267059 - PCDMIS provides RDS installation V2.0.0 instead of 2.1.
267256 - PCDMIS crashes when transforming a step file and click on view setup.
267288 - Script causes incorrect alignment to be recalled.
267350 - Crash When importing DMIS file.
267496 - DMIS Export error when using script files.
257586 - The probe of Arm2 is not visible in the Active List of Probe Utilities.
258797 - Calibration is done ignoring the angular adapters rotations.
262978 - Extreme slowness creating a Freeform scan.
264029 - Crash editing an re-executing a scan.
264158 - Auto Notch Slot ID was not named correctly.
264326 - AutoClip is not applied in the LiveView.
264541 - Auto feature Vector Arrow too long and too big around.
264985 - Tracking Speed is not sent to the SMP400 Controller for BasicScan Linear (Closed-Loop).
265266 - PartProgram.OnExecuteDialogStatusMsg event never called.
265541 - Execution window translation problem.
265928 - After renaming the file is corrupted.
266254 - Adding move/clearplane between hit/basic of autocircle causes a different actual diameter result.
266401 - Problem with AutoFeature vector point and Catia DCT.
266479 - Probe Change corrupts probe file.
266584 - On a custom report user can't change the size on a DimInfo Box that has been already created.
266784 - AutoFeature screen is hidden when a saved window layout is clicked on.
266909 - Analyse area in label is not printed.
266933 - Constructing offset line vector is coming out incorrectly.
266944 - The CAD in not in the PDF-Report by running a Hyper Report.
266982 - XML export/import of distance and angle dimensions doesn't preserve REF_IDs.
267059 - PCDMIS provides RDS installation V2.0.0 instead of 2.1.
267091 - When executing a PP is Impossible to print a Legacy Report (HR) - Report does not show the CAD Window just the border and the DimInfoBoxes.
267109 - Red arrows when the profile is in tolerance.
267188 - The cad axis in the part-setup are changed when are loading a program from V325MR3 to V2010R build 124.
267259 - When you pull the button --> Move To <-- by the Auto Features then you cant close the program.
267367 - Portable Laser Execution fails in a loop.
267427 - Number of hits in the Basic Circle Scan command is not what is expected based on Scan Point Density input.
267533 - Autofeature THEO and ACTUAL change randonly - TARGET stays correct.
267629 - Cannot answer NO to Ok to Empty COP message with a short press of a white button on the arm.
267630 - Cannot use Laser Auto Planes because they cannot be oriented correctly.
267702 - When set thickness in the auto circle measurement the measured results are not correct.
267703 - Problem with probe compensation.
267728 - Program randomly stops in execution mode.
267877 - Custom reports are not showing jpeg files.
267965 - Intermittent hanging.
268064 - Best Fit Plane solved projected to work plane.
PC-DMIS 2010 MR2 contains these main enhancements:
New File Locations (MR2) - In order to comply with standards used in newer supported operating systems, PC-DMIS has changed where many of its files are stored.
Custom PMMC Probe Changer Models (MR2) - For Reporting, new MaxMinSize, MaxColor, and MinColor properties let you customize colors and sizes for max/min deviations.
View Selection for CAD Assembly and CAD Groups (MR2) - The CAD Assembly and CAD Groups dialog boxes now have view selection option buttons allowing you to apply the show/hide properties to specific views.
Screen Counters Moved into Probe Readouts Window (MR2) - The screen counter text has now been redesigned to appear within the Probe Readouts Window instead of directly in the Graphics Display window.
Copy Features without Tips to Clipboard (MR2) - When performing a path optimization, a new Copy to Clipboard button now copies any items in the Features without tips list of the Optimize Path Summary dialog box to the Windows Clipboard.
PC-DMIS Settings Editor Improved (MR2) - The PC-DMIS Settings Editor has been improved to allow you to launch the Settings Editor in a disconnected mode without closing down PC-DMIS. In addition, buttons were added allowing you to backup, restore, or reset user data files.
Use Active Alignment Shows Alignment Name (MR2) - The USE_ACTIVE_ALIGNMENT keyword displays the active alignment used during the last execution.
Select CMS Sensor Types (MR2) - The Laser Sensor tab of the Setup Options dialog box now provides you with a Sensor Type drop-down list where you can define your CMS sensor type.
"True Position" Renamed to "Position" (MR2) - To support the ASME standards, instances of the "True Position" phrase in the user interface and the documentation have been updated to read simply "Position".
The complete list of updates and fixes for this minor version are listed here:
Enhancements:
102866 - Add sphere intersect to circle constructions
103960 - Add form error evaluation for Laser Auto Cylinder
104956 - Equidistant point to CAD borders (Perimeter Point). Step 1: collecting information for creating the User Interface.
106122 - Create ACR1 calibration documentation procedure with pictures of the actual hit locations.
106194 - Equidistant point to CAD borders (Perimeter Point). Developing new User Interface.
106252 - Add Ruler display option to the graphical analysis grid view in custom reporting
106534 - Develop Lathe interface for MDSI control
106535 - Create means to export point and point cloud data to 3rd party software (TCP Conduit)
106572 - Equidistant point to CAD borders (Perimeter Point). Implement RMEAS.
106603 - Add support for customized extended edge point (contact)
106671 - Extended Edge Point - Add to IToolkitCommand interface methods to know if it is a Legacy Extended Legacy or Extended command and to get/set data for Legacy and Extended Legacy commands.
106678 - Provide ability for application to draw custom trihedron
106684 - Draw report vectors in the same color as the vectors but without arrow head
106693 - Implement F9 on a command that belongs to an AUDI toolkit feature to open the related TKF dialog.
106709 - Add new Report template and Label template to the install set to support displaying header information on every page
106712 - Add scaling to analysis view (see enhancement 505997)
106716 - Change the layout of the Extended Edge Point and the PP in the edit window.
106717 - Allow to snap to a coordinate that is entered from keyboard
106718 - Enable reading of CncVariables with non-interactive outputs
106737 - All features inside on an Extended Edge Point feature should be treated as inner features
106748 - T2 comment should show the ID of the previous measured features (RMEAS)
106749 - The Color of the RT vector controls should be equal to the color of the vectors in the GW
106750 - The dialog for Extended Edge Point and PP should behave similar to the AF dialog.
106764 - Extended Edge Point - Apply has to store the settings in the 'Graphics settings' window.
106765 - Extended Edge Point - Make tolerances values for each point save and recall able from a combobox (Item1 Item2 Item3)
106766 - Extended Edge Point - Add new button to the PointRow control to normalize the RT vector
106767 - Extended Edge Point - Make Distance Parameter available in an editable combo box.
106769 - Extended Edge Point - CAD Point should not get drawn in the Graphics window.
106770 - Extended Edge Point - Add GetFeature button control to the CAD point with only the option to select a feature with a click to a feature in the graphics window.
106771 - Extended Edge Point - The controls for the relative measurements in the 'Relative Measure' expander should go to 'General Features Parameters'.
106779 - Fix WAIToolkit.dll references in projects that use it
106811 - Extended Edge Point - Add a protection so that the user can only open the dialog in pp that are using 'mm' as unit.
106816 - Extended Edge Point - Show only the points that are not skipped in the edit window
106850 - Extended Edge Point - DP3 should become skip able only if DP1 and DP2 are un skiped.
106851 - Extended Edge Point - The comment line 2 on DP3 should show the ID's of DP1 and DP2
106852 - Extended Edge Point - Remove timer on the CAD Selection point hook on the lost focus event and add dummy control
106853 - Extended Edge Point - Rework the snap to a user defined CAD selection point.
106859 - Extended Edge Point - Adjust the vectors of the CAD selection point and the DP1 so that they always have the same orientation as the vector of DP1
106905 - Extended Edge Point - Add protection to the UI so the user can't enter invalid numbers
106927 - Extended Edge Point - Add protection so that the application becomes un breakable
107034 - Reflex Vision: Add Setup Dialog For Reflex Vision
107038 - Reflex Vision: Hide options in the Edit Window right click menu
107045 - Reflex Vision: Hide options in the Live View Right Click Menu
107046 - Reflex Vision: Remove options from Feature Target Right Click Menu
107056 - Reflex Vision: Design and Implement new menu structure
107057 - Reflex Vision: Add large toolbar mode and switching to Live View toolbar
107111 - Flip the view for the graphical analysis window (enhancment 506146)
107113 - Better filter for Point Info Label required (task 505994)
107119 - Make PC-DMIS handling the new CMSkit Controller/Sensor Hardware errors (Step 1)
107166 - Remove IViewerCommand
107180 - Add Support for GigE Cameras
107193 - Extended Edge Point - Implement AUDIPLAN rule to compute DP4 and DP5 for flat surfaces
107200 - TARGET MR2 Move User level files to new location outside Program Files folder
107206 - Extended Edge Point - Store the last selected status of the Skip' options for each of the 5 points.
107208 - Extended Edge Point - Add new end criteria to search for DP5
107219 - Extended Edge Point - Enable the SnapSurfaceVector and SnapEdgeVector buttons only if a CADSelection point is present
107227 - Define key words and data structure to use for real time point cloud data export
107228 - Modify PC-DMIS to push data out a TCP/IP link to a third part package
107239 - Add Feature Based Measurement to PC-DMIS
107259 - Create SP600 calibration documentation procedure with pictures of the manual hits.
107260 - Create SCP600 calibration documentation procedure with pictures of the manual hits.
107274 - Update Web Reporter to use the latest HASP library / DLL
107276 - FreeformPlane Import/Export
107278 - Add interfaces to the PCDMIS namespace to control the visibility/access of the tabs within the probe toolbox.
107279 - Implement Wildfire5 DCI
107293 - VW-Benchmark - Make the 'DMIS' created pp logic for the execution of alignment commands available from automation.
107314 - Audi Features - Remove code that use Automation to deal with PCDMIS.
107318 - We need to be able to select features on the graphics view for constructions and dimensions.
107328 - Investigate the cost of implementing accurate movement speed
107330 - Reflex Vision: Make all the required windows visible
107332 - Reflex Vision: Disable the alignment buttins during editing
107333 - Reflex Vision: The alignment button states should reset after feature creation
107338 - Reflex Vision: Execute now should be on for the vision gauge window
107341 - Reflex Vision: Add aligments to the vision gauge window
107346 - Reflex Vision: Disable the load probe message
107347 - Reflex Vision: Remove the status bar
107357 - Add a Square Slot Construction to PC-DMIS
107364 - VW-Benchmark - Add support to project a measured round slot to a plane
107365 - VW-Benchmark - Add support to project a measured square slot to a plane
107371 - VW-Benchmark - Add support to project a constructed round slot to a plane
107372 - VW-Benchmark - Add support to project a constructed square slot to a plane
107386 - Reflex Vision: Modifications to Vision Gage Measurement Tab
107391 - Warnings need fixing and treat warnings as errors switched on for RomerRDS
107395 - Integrate RA7 Inline Scanner using RDS
107400 - Feature extraction library able to work with all the non-contact sensors supported by the company. Integration of the Surfer FEM library.
107406 - Add option for Feature Based Measurement
107407 - Add an option to the matrox framegrabber DLL to load a specified DCF
107423 - Allow the path lines from cursor to work with move path line dialog.
107424 - Allow hide/show assembly properties to be set per view
107438 - Feature Extractor Configuration UI for laser probes
107441 - TARGET MR2 Move default Part Program and Probe folders out of Program Files
107444 - TARGET MR2 Change language code so it doesn't need to move files around in Program Files folder
107451 - Move the NCSensorsLogs containing all the laser logs outside Program Files folder
107458 - VW-Benchmark - Fix the problems with the readpoint alignment is causing a persistent Alignment Error
107459 - Implement a feature extraction library able to work with all supported non-contact sensors. Adding support of different elaboration methods (LMS Min-Max).
107466 - Add ability to select features to display in CRO (EN# 506150)
107470 - Integration of the new non-contact sensor CMS into PC-DMIS. Integrate different CMS toolkit versions in PC-DMIS.
107472 - Convert the attached Mora machine model and rotary table and add to the PC-DMIS machine library.
107473 - Add idn ENC73060. into ManualCMM group for installation plus new XML
107475 - Add native CCIR support to the Matrox FG DLL
107478 - Disable iterate and repeirce when the inputs are laser auto points
107479 - VW-Benchmark - Fix the "Not enough information to construct circle" problem with the auto cylinders when executing offline
107480 - Support the Gemodek implementation of Leitz protocol at MTA aerospace Augsburg
107485 - Change frame grabber install message to be more like the Metris one
107492 - Implement the new Chrylser ExtCmmData.cpp
107494 - Need a launch option for romer integrated scanner
107503 - VW_Benchmark - When I import the CSV File with option SearchRun1 all path lines are odd. CAD and Virtual machine are dancing when I display the path lines.
107512 - Reflex Vision : Add file open button to the part set-up dialog
107513 - Reflex Vision : Remove = from summary mode
107514 - Reflex Vision : Replace standard PC-DMIS background and remove the splash screen
107515 - Reflex Vision : Force large toolbars on for Reflex Vision
107516 - Reflex Vision : Remove version information from title bar
107519 - Remove Windows XP as a supported OS in the ReadMe.txt...
107520 - Reflex Vision : Enabled auto scale to fit
107526 - Reflex Vision : Add infrastructure for TESA icons to Reflex Vision
107527 - Integration of the new non-contact sensor CMS into PC-DMIS. Change installation to support the V.2.20 CMS Toolkit.
107531 - Add "Wrist Type" to UJB Setup
107534 - Reflex Vision : Set CAD and mini-CAD colours
107535 - Reflex Vision : Set the DRO colour
107536 - Reflex Vision : Add target lock/unlock button to LIV toolbar
107548 - Change the default calibration sensor mode to 2
107550 - Create new LAMBDA_50-130-40_CAT machine model
107551 - Add ENABLE/DISABLE VISUAL
107552 - All Toolkit scans should set CreateIntermediatePoints to false
107554 - Disable "even" entries including "Disabled" for the Stripe Filter on SquareSlot if the Contour FE is in use"
107557 - Reflex Vision : Investigate making the tabs on the gage windows bigger
107561 - Remove Insert Tracker command item from SMX laser Tracker Operation Toolbar and from the SMXLaser TRacker Operation Menu
107568 - Reflex Vision : Part set-up dialog should only show Vision probes
107569 - Reflex Vision : We need to be able to print the report
107574 - Implement a feature extraction library able to work with all supported non-contact sensors. Adding control of Ring Band Search Radius RefSurfaceDeviationLimit.
107578 - Reflex Vision : Update the TESA icons
107579 - Reflex Vision : We need to add icons onto all the buttons in the Vision Gage window
107584 - Fix this problem: VW alignment chains breaks in all alignments that have a ROTATE_OFFSET alignment command
107598 - Reflex Vision : Need execute from cursor adding to the Reflex Toolbar
107599 - Reflex Vision : Vision Gage window should remember the state of the advanced/simple button
107600 - Reflex Vision : Changed the summary mode font for Reflex Vision
107604 - Add option for ignore comments during collision detection
107606 - Construct circle at height from a cylinder
107607 - Reflex Vision : Cad View = Graphics View
107611 - Reflex Vision : Remove right-click Setup from DRO
107618 - Integrate Languages in WiX installer and convert Languages to merge modules
107619 - Implement a feature extraction library able to work with all supported non-contact sensors. Add the support functionalities for IN/OUT
107622 - Reflex Vision : Double clivk on CAd feature labels should be disabled
107623 - Reflex Vision : CAD label right click menu should be simplified
107624 - Reflex Vision : Reflex Vision should not be able to load PC-DMIS part programs
107625 - Reflex Vision : Add a reset graphics view button to the Reflex Vision toolbar
107627 - Check integration with Zeiss server in Dual Arm context
107637 - Implement a feature extraction library able to work with all supported non-contact sensors. Show the button "Feature Extractor Configurator" with a secret key sequence or with an undocumented registry key.
107642 - Integration of the new non-contact sensor CMS into PC-DMIS. Change the original 6 Modes to Zoom Settings (step1)
107648 - Reflex Vision : Popup messages (Error Messages) have PC-DMIS in title bar
107649 - Integration of the new non-contact sensor CMS into PC-DMIS. Change the original 6 Modes to Zoom Settings (step2)
107650 - Extended Edge Point - when I change the ID of an inner feature the comments should update
107651 - Extended Edge Point - Add new Toggle for DP5
107655 - Reflex Vision : Add PDF print button to Reflex Vision toolbar
107659 - Reflex Vision : A support for looping to Reflex Vision
107660 - Reflex Vision : Move the Manual/DCC buttons from the Reflex Toolbar to the Vision Gage Window
107663 - Live View toolbar sliders are too keen to disappear
107675 - Extended Edge Point - Make it possible to overwrite an existing T-Rule combo box item
107677 - Add button to copy features without tips to the Clipboard
107680 - Implement the new screen counters design
107684 - Display the current qualifying tip
107686 - When I edit the Y coordinate of a Section cut plane the vector snaps to the closest boundary and doesn't keep the major direction of the previous computed plane vector.
107687 - Add Start Angle and End Angle to PlaneCircleScan strategy
107693 - Implement a feature extraction library able to work with all supported non-contact sensors. Support the N-Sigma
107694 - Upgrade to Datakit v6.4
107697 - Implement a feature extractiion library able to work with all supported non-contact sensors. Add the SPHERE element.
107699 - Add IDS UEYE 3.60 frame grabber DLL to the build and to the install for vision
107701 - VW-Messprinzipien: BF Fix this problem : We need only one CAD selection point
107707 - VW-Messprinzipien: BF Fix this problem : Application is crashing when you F9 on the existing command
107709 - Add GetTempFolder to WAIPath and use for Temp files
107712 - Extended Edge Point - Fix this Problem: The Comments for the Dimension may not draw in the reports when the E-Rule is set to NONE
107713 - Extended Edge Point - Fix this Problem: Minus Tolerance in Dimension labels for TK features are wrong.
107715 - Zeiss interface 1.92n - numerous fixes and improvements
107716 - 3 more files created in install folder at runtime need moving to new location
107718 - Implement a feature extraction library able to work with all supported non-contact sensors. Support the fitted Point
107722 - Add a FLIP_VECTOR config option for vector calculation
107739 - Fix this problem: When they use the 'Close' button the feature label in the GW disappear
107744 - Reflex Vision : Update TESA Icons to the 2010-05-26 icon set
107745 - Reflex Vision : Disable the message that is displayed when the maintenance agreement has expired
107764 - Consolidate more path functions
107774 - AUDI PressShop: Please make the "Initialize Sensor" message more visible for both arms
107781 - Lengthen the COP drop-down box in the Laser Properties toolbox
107785 - Add new RomerRDS interface to Proglock/MYHASP for PC-DMIS Reshaper
107787 - Add the current output full path name (PDF file or RTF file) via automation.
107788 - Add top, left, height, and width Automation properties to the report window
107790 - Create Interface for CPCDpart_program
107793 - Improve schema/serialization handling to help with corrupt part programs
107794 - Refer to Supplementary cd as Modules as this is what the zip is
107798 - Test UG DCI with UG NX 7.5
107800 - 'Update commands with the new part alignment' dialog is confusing the operators at VW/AUDI in South America
107807 - FreeformPlane: Allow Theo Vector to be edited
107809 - Improve CMS error recovery
107810 - Extended Edge Point - Fix this Problem: The Comments for the Dimension must not start with colon.
107811 - Add support for DMIS 05.2.
107813 - We need to improve the efficiency of Optimized 2D profiles
107817 - Extended Edge Point - Fix this problem: NOMINAL and MEAS on the dimensions are out of sync with the THEO and ACTL of the internal features
107887 - Integration of the CMSKit Ver. 2.50 into PC-DMIS
107888 - Add MIL9 R2 from Matrox for Win7 32bit support
107889 - Add the new MIL9.0 R2 DLL to the installer
107894 - Add an OS check to the installer to flag unsupported DCI's...
107903 - Implement a feature extraction library able to work with all supported non-contact sensors. Extend N-Sigma (ouliers removal) to all the others features (plane, circle, slot, and hexagon)
107904 - Don't allow restore of settings from more recent version of the product
107905 - Don't startup product when start Settings Editor
107909 - Allow full backup / restore to be done from Command line
107912 - Implement a feature extraction library able to work with all supported non-contact sensors. Expose the version info to the DLL properties
107916 - Implement a feature extraction library able to work with all supported non-contact sensors. Install the new FeatureExtractorWAI libraries with PC-DMIS
107923 - Add suport for the NI PCI -1405 frame grabber from National Instruments
107924 - Add fly mode support to Mycrona HSI
107925 - Add support to HAL/HSI interface to return latched rotary positions
107485 - Change frame grabber install message to be more like Metris one
107694 - Upgrade to Datakit v6.4
107424 - Allow hide/show assembly properties to be set per view
107873 - Use selected surfaces only for Face and point colormap
107866 - Perimeter Point - Fix this problem: The path lines we draw for the perimeter points are too long
107020 - Extended Edge Point - Give access to the internal commands of a toolkit feature
107327 - Add an option to perpendicular plane to have the resultant plane be coplanar with the line that is used as the input
108065 - Add Hasp SRM is coming warning message at startup to start the move over
107804 - Implement the new ExtCMMdata
Fixes:
209979 - Axis dialog confusing
231639 - Press F5 and Select "Use DMIS Button in Edit Window" requires a restart on PC-DMIS to enable
232255 - Report Magnification should add a '%' when you've added a custom size and tabbed away
234509 - Can't get the menu option (File | Launch | Quindos) to be enabled
237298 - TEXTONLY report header computes revision number and serial number instead of displaying it
238873 - Printing a DMIS Output file should only print to a .dmo file.
245930 - "Toggle Graphic Window in Wireframe" and "Toggle Graphic Window in Solid" menu options are not really toggles at all.
246271 - DF axis on FCF advanced page always has "Update feature nominals" checked
247905 - Copy line construct code in program causes application crash
248518 - Screen capture in a custom report does not work and corrupts program.
249312 - The Settings window shows also unavailable parameters
251389 - Nothing happens if I drag Part Name onto a cell of a grid control
253574 - Too much of the Rule Tree Editor is exposed for the Label object
255278 - Page Up/Page Down is not working well.
255658 - Cannot Save Wrist Orientation
255907 - The feature labels are drawn in the graphics when I create an auto feature even if the appearance for the feature labels is turned OFF in the part program
255979 - 'An Attempt was made to access an unnamed file past its end' caused by 'UseImageCachingScheme' enabled
256396 - The click selection for auto edge point fails on many of the surfaces of my reference part
256468 - Pressing F9 on feature - With AF dialog open pressing enter or escape is not closing it down correctly
257099 - Mirror is not working as required. Mirrored tip commands are all wrong.
257135 - We don't store the lastest user selected 'Reporting Mirror Option' in the 'Choose part to mirror dialog
257731 - The custom reports do not display the correct data when the feature is unmarked.
257929 - PCDMIS Crash
257941 - The function "Ignore Motion Errors" doesn't work correctly.
258188 - We save automatically a report in the RW if we open another report in the RW without any notice
258394 - Manually turning on feature labels is not persistent.
258494 - Generic Export does not apply probe compensation to scan data correctly.
260369 - Leaderlines of distances with setting "at 2 features for distance" is drawn double.
261523 - How to read all dimensions output by FCF using Automation?
262178 - DrawPathLinesRadiusinMM registry entry does not match the corresponding value in the Display Symbols dialog...
262404 - Modification for the German language for Dimension color
262514 - Rotary scan can't create scanning data into plolar coordinate system
262586 - A big arrow is displayed and stayed in CAD view after cancellation of the feature until we close and reopen part programs
262753 - Feature always executes in DCC mode
262957 - An exchange of the label template in custom reports is not persistent
263001 - Cannot turn off the rules for the CRO in the report window
263270 - DataChangeListener is not working properly
263322 - Multiple arm slave laser "offset" procedure does not work.
263444 - Constructed circle from two AFCircle - CircleAnalogScans doesn't work
263629 - AutoInspect: RMS value in Hit does still not update correct if executing in DCC mode
263688 - 3D Line Tests Problems with reported form error and parallelism
263961 - X-coordinate in the PC-DMIS command on an unbounded line is different compared to the DMIS FEAT/LINE statement in the DMI file
263971 - Edits to Freeform scan path points not retained after closing dialog
264378 - The text on label ?Durchmesser' in the German 'Abh?ngiger Kreis' dialog is truncated
264380 - The text on radio button ?Offsets' in the German 'Geradenvers?tze' dialog is translated wrong - Should be again 'Versatz' as it was in all previous versions
264381 - The text on button ?Offsets' in the German 'Geradenvers?tze' dialog is translated wrong - Should be again 'Vers?tze' as it was in all previous versions
264382 - The text on radio button ?Innen' in the German 'Abh?ngiges Langloch' dialog is truncated
264383 - The text on radio button ?Au?en' in the German 'Abh?ngiges Langloch' dialog is truncated
264384 - The text on radio button ?BE Neukompensiert' in the German 'Abh?ngiges Langloch' dialog is truncated
264388 - The text on label ?Passpunkte bearbeiten' in the German 'Abh?ngige Kurve' dialog is truncated
264389 - The text on button ?Auswahl aufheben' in the German 'Abh?ngige Kurve' dialog is truncated
264401 - The text on Label ?Duchmesser' in the German 'Abh?ngiger Kugel' dialog is truncated
264406 - The menu item 'Wahre Position In zwischen' must become ?Position Dazwischen' again
264415 - The text on button ?Speichern unter' in the German 'Druckoptionen Protokoll' dialog is truncated
264416 - The text on radio button ?Eingabeaufforderung ' in the German 'Druckoptionen Protokoll' dialog is truncated
264420 - The text on checkbox ?Ausrichtungen zeigen' in the German 'Protokoll' dialog is truncated
264507 - Lathe Work Offset axes are not returned in correct order in journal file
264624 - When F9 on this alignment alignment steps blow up into many steps and don't match edit window and two alignment dialogs come up.
264746 - Executing the attached PP PC-DMIS takes up to 40 minutes to evaluate dimensions and then generates the DMO file.
264845 - Unable to load Iges or previously created .cad files.
264976 - Bundle doesn't run properly with more than 9 points
264989 - Generic feature does not mirror in Y-axis
265005 - Labels in iterative alignment change
265050 - Program will not open - application error.
265100 - Program is trashed with Serialization error after CANCEL on dual arm laser program
265142 - When opening the attached part program in the latest pcmdis 2009 the application will crash
265173 - TCL Scripts need to be updated to reflect changes in Scripting Generator
265322 - Graphics Window is blank or missing features unless you close and open the mirrored program a 2nd time.
265428 - Show points in the Analyse window
265430 - Modification for the German language Parameters Opt.Probe
265431 - Modification for the German language Parameters Taster Trigger
265432 - Modification for the German language for Parameters_IO Channels
265480 - Modification for the German language for CAD and Graphic Setup (Lighting)
265481 - Modification for the German language for CAD and Graphic Setup (Material)
265482 - Modification for the German language CAD Elements
265483 - Modification for the German language CAD Assembly
265484 - Modification for the German language for Alignment Utilities
265485 - Modification for the German language for Construct Circle
265643 - Migrated programs with Auto features that have pathlines turned on move when edited
265652 - Arm2 doesn't start its execution
265661 - The Concentricity Dimension doesn't work
265721 - If a Brown and Sharpe Jogbox is attached to a Sheffield Controller and Servo Power has not been applied before PC-DMIS launches then PC-DMIS will hangup
265845 - Zeiss PSM machine. After electronic maintenance it starts flipping vectors for manual measured features
266152 - FreeformPlane: Add option to delete data points before saving
266195 - Error constructing a cylinder by 2 circles
266199 - True position evaluation of cylinder does not display the correct axis values for evaluation point in summary table
266283 - Managed memory is hemoraging at Cummins
266297 - Should keep same object selected
266320 - MessageBoxOption.dat Empty
266417 - Path limitations for DMIS output files with index option active
266636 - Point Cloud toolbar is not fully disabled if disabled on portlock
266644 - Large size Report template file
266645 - CMM is moving directly to calibration sphere when calibrate button is clicked in Metrosoft
266704 - FDC interface: replace the SET_PAR command with SET_VAR command.
266801 - FS#2267 We can not import the CAD File
266828 - Summary table for FCF's isn't right.
266856 - Application error on CallSub command
266897 - Problem with building portable interfaces
266946 - When viewing a Custom Report in the Report Window, the menu items "Edit Object..." and "Remove Object Modifications" should be disabled from the popup menu
266964 - Impossible to hide Five Unique Columns on a Legacy Report
266996 - The Form Feed does not work by printing-RTF
267015 - ISO limits do not work with circles with different diameters
267031 - When focus fails, focus target remains locked to the part, making it very difficult to adjust a mispositioned target
267187 - Clearplanes have another position from offline program to online program when you activate "Toggle Clearance Plane Items"
267040 - Polar Vector Compensation does not work on a portable machine - Faro Arm or Romer Arm.
267188 - The cad axis in the part-setup is changed when are loading a program from V325MR3 to V2010R bild 124
267232 - DCC machine flips the point vector randonly when measuring in man mode
267280 - The Vision Reflex part program setup dialog presents some localization issues.
267326 - ZEISS CMM always homes
267330 - Not possible to dimension true position (FCF) of a line
267343 - On the Analysis Window Object the profile dimension Tol Limits are not drawn following the curve profile
267373 - Forms aren't displayed to the operator when PC-DMIS runs as invisble or minimized.
267385 - Too many decimal places are posted for Haas control.
267394 - Intermittent latching issue with CMS on RA7 arm
267395 - BFRE plane with Gauss filter discards 2 of 4 points so flatness is invalid
267430 - CMS Stripes in Qual not implemented for portable systems
267435 - Learn AF - Messages can disappear from the status bar
267441 - Learn AF - Apply changes introduced in PR
266540 to other AFs
267450 - Cannot disable a Radio button on a form.
267454 - Attempting to generate probing macros after saving setup fails.
267467 - Tesastar-m head does not rotate when commanded by UJB on DC controllers
267470 - AF: In command mode pressing F9 on hits opens the HIT dialog on some AFs and opens the AF dialog on some others.
267491 - Setting rotary table number to zero does not zero out the associated table definitions
267492 - Move Station Command always refers to nominal values if Part Program is closed and reopened
267502 - After using CTRL-U program gives error, locks up, and then crashes PC-DMIS.
267542 - We don't save the report template with correct schema
267545 - CRO Advanced Property "PCDMIS Command Object" doesn't add label/leader line when a dimension or feature control frame is selected.
267547 - We need the ability to optionally display the number of laser hits in real time
267549 - Get CircleAnalogScan, CylindricalAxisScan, CylinderSpiralScan, and CylinderConcentricCircleScan working.
267594 - Auto Move distance for AutoFeatures defauts back to 0 when you close pcdmis and restart it.
267614 - Simultaneous evaluation dimension in the report changes after saving, closing, and reopening part program.
267615 - Customer's CAD files will not work in any version other than 4.2 mr1
267618 - Star probe no longer highlights active tip
267626 - Machine interfaces are incompatible with PC-DMIS 2010 Build set 52
267637 - Software crashes using customer's part programm with version 2009
267643 - Interlocks between GDT&T standard and user-selectable options are not correct
267668 - Rotate Alignment does not export fully to XML
267677 - Filter sets do not have outlier removal enabled or are ghosted out.
267682 - Crash on message of probe deflected
267687 - Subroutines can't record the parameter when I use the Call Sub command
267712 - Preview Window not updating coordinates in Point Only Mode
267744 - Expressions using hit array in a construction are not updating
267760 - Part program Iso-4 with lspx_1_S doesn't perform the scan
267780 - 4-axis rotary table scan - section cut scan doesn't stop when scan path is generated. It passes the end point and continues to generate additional points.
267787 - If I select a feature from the PC-DMIS Comands dialog for a CRO, the combo box switches to Page instead of remaining on the CRO
267795 - Solidworks gives an error when trying to use DCI.
267808 - Weather station registry settings aren't saved correctly
267846 - Screen counter doesn't work
267860 - Opening and closing this program causes PC-DMIS to crash
267870 - Looping Single Point measurement in DCC fails
267881 - ASCII Import translation files not installed with portable interface
267902 - Distance dimension reports the negative nominal values
267904 - System can not be operated with remote control (CTRL+H). Execution mode options dialog seems not to accept anymore measurements even if the status goes to 'is busy' and back to 'ready'
267909 - Change Manager inserts an "End of Dimension" statement in a true position dimension statement
267912 - Location dimension can't apply the correct unit between MM and INCH
267920 - Customer wants to add "Use Legacy Dimensions" menu item to a custom toolbar but it is not available.
267928 - LeaderLine in Object Bar creates a triangle instead of a line. Custom report and report template have same issue.
267934 - Application Error cancelling some parts of the program in Edit Window.
267948 - Carry Nominals back to feature prompt pops up during execution.
267985 - Infrequent Crash during CMS qual
267993 - AT401: Toolbars incomplete
267995 - AT401: After having started the TrackerPilot once the system does not set Cartesian Coordinate system on the Server all subsequent measurements are wrong!
267996 - AT401: If insert tracker commands is enabled and Go0Pos is chosen in the tracker menu a Tracker command Go_Birdbath is added
267998 - AT401: if creating a new part program no tip is selected and the first row in the part program is highlighted
268000 - RMEAS Default Mode causes feature to measure at Relative Measure Feature centroid
268016 - Temperature Dialog Entry Issues
268030 - PCDMIS crash when I try to insert an Auto Cylinder using the toolkit CylinderConcentricCircleScan Strategy.
268035 - AT401: PC-DMIS seems not to use the latest sensorerror.dll
268036 - Reflex Vision: Sensi-light needs to be disabled if previosuly enabled in pc-dmis
268037 - Reflex Vision: Surface point only performs 1 focus
268038 - Reflex Vision: Focus parameters do no appear to be working
268045 - It would need to update the date of the About dialog
268060 - XML file has been locked during PC-DMIS opening
268065 - Application is crashing when I execute EEPNT1 with CRTL-E
268080 - Their 42 reports show messed up in 2010 MR1
268084 - Comment with attached picture will not display picture after reopening the program
268087 - When they open 42 pps in 2010 MR1 RC unselected nodes in the CAD assembly tree are selected (Build 48)
268089 - Serv1.stp file is not read
268090 - Extended Edge Point - The path lines are odd the first time they draw after the EEP dialog has been open.
268091 - If a reflector name is blank "", PC-DMIS crashes at startup
268096 - Missing surfaces in the attached NX 7.0 model...
268098 - Untrimmed surface on this model compared to NX 7.0...
268104 - Inconsistency between PC-DMIS UI and OLH with the 'Rotate' dialog.
268108 - It is difficult to move an AF's individual user-defined hits with the mouse
268109 - Application is crashing during the view path operation at - CS4 =FORM/FILENAME= G:\_TMP\AUDI STAMPING\KOPF\FORMBLATT1.FORM
268115 - Using Program Mode the vector of the hit doesn't immediately appear. But it does after a refresh of the screen.
268132 - AUDI Tk Features internal dimensions do not mirror properly
268138 - Features not being displayed in CAD window
268167 - Pin Nest Probe creation problem
268187 - FDC interface command modification
268192 - The Part/Machine axis setting (from the F5 dialog) gets lost when saved to v42 pp
268194 - Mysterious results for true position (ISO)
268195 - Executing the attached program in offline causes PC-DMIS to crash and deletes the point cloud
268208 - Application Error results when clicking with the mouse on the Edit Window with the Auto Cylinder dialog open.
268212 - Problem after updating to Version 2010 with the attached part programs
268214 - Different behaviour regarding the activation of the temperature compensation between DC and CC
268216 - Missing data on the client scanning at 30 Hz using the TCP/IP direct link
268222 - Pcdmis is changing 3 random points during execution in the actuals that seem to be like 14 or 13 inches off
268226 - On a Dual-Z machine the wrong (Video) Z axis is moved during tool change operations
268234 - The parameters of the Animation tab (Setup Option dialog) don't remain memorized.
268235 - System fails to initialize if I swich to the LaserProperties tab while the LiveView is opening
268237 - After selecting "Path Lines From Cursor" if you then access the Edit Menu, it provokes an annoying refresh.
268238 - When "Path Lines From Cursor" is activated the Optimization Path doesn't correctly work.
268240 - Machine Parameter out of tolerance using "Auto Insert Moves".
268242 - Auto Plane feature is no longer showing the Coordinate Type in Summary mode.
268250 - Iterative Alignment doesn't export to IP properly
268256 - Edit Auto Features Path Lines does not work properly
268287 - The UJB will display an illegal move is being attempted when trying to select any angle position.
268289 - CME cannot handle Coaxiality FCFs.
268294 - Allow Section Cut object to be displayed even if there is no CAD file (as part of the image caching)
268295 - Change Manager can't handle this IP file
268297 - The code: this.Bitmap = "filename.bmp" does not load picture
268311 - Every time I press the RecordMove button on the UJB it inserts two moves into my program.
268317 - PC-DMIS looking for compensation file 'comp.enc' instead of 'comp.dat'
268332 - Audi Extended Edge - Show Path displays wrong path
268347 - New System default path is not used for part program name when using automation
268353 - The measure value is not correct when analyzing a 2D angle for a cone and a cylinder
268355 - The tracker status bar is not updating colors
268360 - Why do all of the dimension color bars show Red even though they are not out of tolerance?
268362 - ASSERT and possible crash when adding Audi EEP
268363 - FBM function can't mark all relative commands
268364 - After I finish the FBM XML file importing, pc-dmis can't open other pps
268400 - Cannot use COPOPER commands as inputs to constuctions
268417 - Application is crashing when I open the report window (Custom Build #5)
268433 - Editing a label by clearing non-heading items and selecting its Resize Type to "Hide Text Only" hides the heading line too
268436 - Raytheon cannot load proewildfire5.dll
268466 - The XCEL 7-10-7 machine will not draw completely in PC-DMIS.
268497 - AnalyzeWindowObject - When I enable transparency on the AWO in the custom report editor the bitmap with the profile shows empty.
268560 - Crash executing a RoundSlot extracted from a COP
268595 - The knuckle_M4 is rotating incorrectly in the EDIT Probe Component for the Joint: Knuckle
268620 - Cannot View Report Window with this PRG. Also when Ctrl-U PC-DMIS Crashes
268643 - PCD 2010 MR2 T2 Custom Build - The Preview Window doesn't report the values of the measured points.
268655 - Min / Max crashes in offline
268763 - invalid PDF fille if REPORT/LEGACY does not contain a full path to the file
258897 - Selecting OK on round slot auto feature dialog unnecessarily gives PCDMIS message about default id.
259002 - Do not changed new position in Auto High point.
261221 - Sensor Hardware Error dragging the clipping region due to missing limits.
262477 - Can't measure a Square Slot using the Point filter result is Feature Calculation Error
262686 - Summary and Command mode are out of sync - automation returns incorrect hits for auto polygon features
262774 - The message "You are about to re-generate the hits which overwrite the previously defined user hits. Is this OK?" appears 3 times
267677 - Filter sets do not have outlier removal enabled or ghosted out
267993 - AT401: Toolbars incomplete
267996 - AT401: If insert tracker commands is enabled and Go0Pos is chosen in the tracker menu a Tracker command Go_Birdbath is added
267998 - AT401: If creating a new part program no tip is selected and the first row in the part program is highlighted
268035 - AT401: PC-DMIS seems not to use the latest sensorerror.dll
268091 - If a reflector name is blank "" PC-DMIS crashes at startup
268167 - Pin Nest Probe creation problem
268195 - Executing the attached program in offline causes PC-DMIS to crash and deletes the point cloud
268400 - Cannot use COPOPER commands as inputs to constructions
266636 - Point Cloud toolbar not fully disabled if not on portlock
267870 - Looping Single Point measurement in DCC fails
268084 - Comment with attached picture will not display picture after reopening the program
268216 - Missing data on the client scanning at 30 Hz using the TCP/IP direct link
268355 - The tracker status bar is not updating colors
268560 - Crash executing a Round Slot extracted from a COP
268096 - Missing surfaces in the attached NX 7.0 model...
261809 - Collision with Auto Relative Measure by belongs to intersection point
261491 - High errors ( up to 1mm ) on some tips calibrating CMS sensors
268132 - AUDI Tk Features internal dimensions do not mirror properly
268000 - RMEAS Default Mode causes feature to measure at Relative Measure Feature centroid
267668 - Rotate Alignment does not export fully to XML
265466 - The procedure "Calibrate the unit" crashes PC-DMIS
268900 - AF Edge Point - Feature deviation is wrong when working with cylindrical probes.
266574 - V5 Z-Scale file error not making it to the user
268360 - Why do all of the dimension color bars show Red even though they are not out of tolerance?
269037 - CAD alignment is lost after bundle
256419 - Using a CAD model's Theoreticals for the second feature measured (used for Rotation in the alignment) change during execution on a Faro Arm (Platinum) causes the cad to show incorrectly in the graphics window for the remaining feature measurements.
261976 - AUDI-ING A1 - Feature has wrong actuals in dmo output
262957 - An exchange of the label template in custom reports is not persistent
268192 - The Part/Machine axis setting (from the F5 dialog) gets lost when saved to v42 pp
268767 - AT401: Tracker Toolbars will not be installed correctly
268396 - Serialization Errors running scripts which worked fine in previous versions.
267995 - AT401: After having started the TrackerPilot once the system does not set Cartesian Coordinate system on the Server all subsequent measurements are wrong.
269074 - Missing "Circle U" symbol in drop down box of FCF for Unequal tolerance zone
269070 - When using Auto Features and moving a point via the Show Hits toggle, the measurement is not updated after execution.
Occasionally files for supported machine interfaces are changed or added outside of the normal PC-DMIS version release parameters. Follow this link to download any updated or new interface files this version of PC-DMIS.
To install an interface file:
Follow the link above and download the .dll file to a directory of your choice.
Rename the DLL file to interfac.dll.
Place interfac.dll file into the directory where you installed PC-DMIS.
Sometimes user interface files (resource files) are updated outside of the normal release. Most of the time this will only happen for supported non-English language installs.
Links with instructions will appear here if this information is needed for this version.